34-085-21143

Well Details

Well ID: 34-085-21143
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: COVERT
License Status: Producing
License Date: 2005-02-03
Spud Date: 2005-05-24
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2005-05-28
Well Total Depth: 3417.00 ft
Configuration: Vertical
Latitude: 41.580000
Longitude: -81.410000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-02-03 Proposed Formations:CLINTON, Issued Date:2/3/2005, Expired Date:2/3/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-05-24 RBDMS Rec
Completed 2005-05-28 RBDMS Rec
Reached Total Depth 2005-05-28 RBDMS Rec
Completion Report Received 2005-09-06 RBDMS Rec
Construction Permit Expires 2006-02-03 RBDMS Rec
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2005-11-03 3179 3232 16
3179 3232 16
3179 3232 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 417 Bbl 90000 500 GALLONS HCL ACID & 535M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 GREAT PLAINS EXPLORATION LLC 3631.00 1048.00 365
2006 GREAT PLAINS EXPLORATION LLC 3373.00 1566.00 365
2007 GREAT PLAINS EXPLORATION LLC 2533.00 1144.00 365
2008 GREAT PLAINS EXPLORATION LLC 2325.00 925.00 365
2009 GREAT PLAINS EXPLORATION LLC 2469.00 495.00 365
2010 GREAT PLAINS EXPLORATION LLC 3528.00 1164.00 365
2011 GREAT PLAINS EXPLORATION LLC 3875.00 961.00 365
2012 GREAT PLAINS EXPLORATION LLC 4311.00 835.00 366
2013 GREAT PLAINS EXPLORATION LLC 3018.00 580.00 365
2014 GREAT PLAINS EXPLORATION LLC 2799.00 464.00 365
2015 GREAT PLAINS EXPLORATION LLC 1381.00 116.00 365
2016 GREAT PLAINS EXPLORATION LLC 427.00 0.00 304

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 GREAT PLAINS EXPLORATION LLC Brine 230 365
2006 GREAT PLAINS EXPLORATION LLC Brine 230 365
2007 GREAT PLAINS EXPLORATION LLC Brine 660 365
2008 GREAT PLAINS EXPLORATION LLC Brine 280 365
2009 GREAT PLAINS EXPLORATION LLC Brine 400 365
2010 GREAT PLAINS EXPLORATION LLC Brine 640 365
2011 GREAT PLAINS EXPLORATION LLC Brine 400 365
2012 GREAT PLAINS EXPLORATION LLC Brine 240 366
2013 GREAT PLAINS EXPLORATION LLC Brine 300 365
2014 GREAT PLAINS EXPLORATION LLC Brine 90 365
2015 GREAT PLAINS EXPLORATION LLC Brine 0 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1116755383 2005-5-25 0:00: DD No Violations
-1519141111 2017-12-14 0:00 UP No Violations 0.50
-1761427065 2005-7-6 0:00:0 DD No Violations
-1917993732 2016-2-29 0:00: UP No Violations 1.50
-2027696343 2012-9-12 0:00: UP No Violations
-645069699 2012-3-19 0:00: UP No Violations
-657168794 2005-5-23 0:00: DD No Violations
-711745807 2019-10-2 0:00: UP No Violations
-929325502 2005-5-31 0:00: DD No Violations
0645069699 2012-03-19 UrbanProduction Wells No Violations My inspection today found that the stuffing box had leaked 2 to 3 gallons of crude oil around the well head. I applied sorbent pads to the affected area and stopped the oil from flowing away from the well head. I contacted the well owner and informed them of the problem. The well tender was on site within one half hour and shut the well down, cleaned up free oil/spent pads and mixed Peatsorb into the soil around the well head. The total area affected from the leak was approximately 80 square feet. I informed the well owner, during this inspection, that locks are needed on the load line valves at the tank battery. The tank battery is not fenced and there is no HB-278 equipment installed on the tank battery. Preliminary Restoration was passed by a senior inspector in 2009.
0657168794 2005-05-23 Drill / Deepen / Reopen No Violations moving rig to this site instead of jackson st
0929325502 2005-05-31 Drill / Deepen / Reopen No Violations moving to feldstien
1116755383 2005-05-25 Drill / Deepen / Reopen No Violations Surface
1145897860 2005-05-27 Drill / Deepen / Reopen No Violations on site to check for odor complaint no address given called fire dept they had checked out the odor was coming from rig

the rig had switched to fluid no odor at time of inspection.

Case closed

1310041761 2011-07-07 UrbanProduction Wells No Violations Wellhead is a pumpjack in good repair. Lease road stable, dike in compliance. ID signs in place. Tank battery contains 1-210 bbl and 1-100 bbl production tank in good repair. Vent hatches installed and closed. Site is pre HB278.
1336995622 2012-05-10 Production Wells Violations Noted On 5/10/2012, I performed a production well inspection status check with DNR Inspectors Tom Hill and Mike Dinsmore. My inspection found the pumping unit had a small drainage ditch within 5 feet of the well head. DNR Inspector Tom Hill called Great Plains Exploration and instructed the well tender to put a dike around the well head. The tank battery contained one 210 barrel oil storage tank, one 100 barrel brine tank, and a separator and I noticed no visible spills or leaks. The lease road was in good condition. I will perform a follow-up inspection by 5/18/2012.
1339422841 2012-05-10 UrbanProduction Wells No Violations My inspection today was to follow up on the oil spill clean up progress. The operator has a dike built around the wellhead, that is 2/3 completed. Operator was contacted to close of dike to prevent fluid release from the well, which is equipped with a pumping unit. The peat-sorb that has been mixed into the soil during spill clean up has stabilized the remaining free crude oil on location. Operator was contacted to remove remaining saturated peat-sorb. Operator has removed absorbent pads from location. Production facility was in good repair. The lease road was stable.
1482275234 2016-12-20 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had observed that there was oil leaking from a back-pressure valve and from gas leaking from a fitting at the wellhead. I had notified the company and they had indicated that they would address the leaks. At the time of the this inspection, the previously-noted leaks had been repaired and there was no visible oily impact to the ground surface. Fittings and connections at the tank battery and wellhead were secure. Secondary containment was intact and dry. The access road was mostly-snow covered but passable.
1519141111 2017-12-14 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery. Fittings and connections at the wellhead and battery were secure with no signs of leakage or problems. The short access road was snow-covered, but accessible. The ID signage had been updated. The well was in active production. There was an active chart record.
1587027228 2009-04-07 Preliminary Restoration No Violations
1588604699 2020-5-4 0:00:0 UP No Violations
1761427065 2005-07-06 Drill / Deepen / Reopen No Violations Pits closed area leveled.
1917993732 2016-02-29 UrbanProduction Wells Violations Noted I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following elements: one wellhead with pump jack system, one mechanical separator, and a tank battery comprised of one 210-barrel steel tank, one 100-barrel steel tank, and mechanical separator, with associated fittings and tubular connections. Secondary containment was intact. Access to the well is afforded by a short dedicated, unpaved access road which enters from Chardon Road. At the time of this inspection, the road was in good condition. I observed the following deficiency: oil was leaking from the back-pressure valve at the wellhead forming a small (less than 8 oz.) puddle at the base of the fitting. In addition, I observed gas leaking from a fitting at the wellhead near the drip tank and gas connection for the pump jack motor. I contacted Keith Krejci with Great Plains Exploration and advised that repairs must be made immediately. The owner must remedy the following by 02/30/2016: Fix the leaking oil from the back-pressure valve and the leaking gas connection. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
2027696343 2012-09-12 UrbanProduction Wells No Violations The unit consists of a 2-tank battery (TB) with mechanical separator enclosed in a 6-foot fence. The spacing is in accordance with the rule, and the valving and mechanicals are in good repair. I did not observe any signs of leaking product or gas vapors. The wellhead is fitted with a pump jack which is producing. The tank battery dike is adequate. Locks and ID are good. No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1336995622 US-OH-109699 2012-05-14 General Safety
1917993732 US-OH-119274 2017-10-13 9-1-07 Well operation causing pollution and contamination

For data sources see[9]