If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21149 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.71,"lon":-81.26,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: ROCKEFELLER OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: KNIGHT | |
License Status: Producing | |
License Date: 2005-06-06 | |
Spud Date: 2005-11-03 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2005-11-09 | |
Well Total Depth: 3278.00 ft | |
Configuration: Vertical | |
Latitude: 41.710000 | |
Longitude: -81.260000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2005-04-19 | Proposed Formations:CLINTON, Issued Date:4/19/2005, Expired Date:4/19/2006 6:00:00 AM, Drilling unit acres:25.77, Proposed Well Type:OG, Proposed Well Class:POOL |
APP | 2005-06-06 | Proposed Formations:CLINTON, Issued Date:6/6/2005, Expired Date:6/6/2006 6:00:00 AM, Drilling unit acres:27.63, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2005-11-03 | RBDMS Rec |
Completed | 2005-11-09 | RBDMS Rec |
Reached Total Depth | 2005-11-09 | RBDMS Rec |
Completion Report Received | 2006-03-21 | RBDMS Rec |
Construction Permit Expires | 2006-06-06 | RBDMS Rec |
Change of Owner | 2016-12-05 | Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-06-14 | 3018 | 3028 | 13 |
3018 | 3028 | 13 | |
3018 | 3028 | 13 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 448 Bbl | 100000 | 492M SCF NITROGEN ASSIST |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | GREAT PLAINS EXPLORATION LLC | 4243.00 | 0.00 | 58 |
2006 | GREAT PLAINS EXPLORATION LLC | 20417.00 | 5.00 | 365 |
2007 | GREAT PLAINS EXPLORATION LLC | 14747.00 | 0.00 | 365 |
2008 | GREAT PLAINS EXPLORATION LLC | 12872.00 | 45.00 | 365 |
2009 | GREAT PLAINS EXPLORATION LLC | 15531.00 | 0.00 | 365 |
2010 | GREAT PLAINS EXPLORATION LLC | 13891.00 | 0.00 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | 16006.00 | 0.00 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | 13452.00 | 0.00 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | 11316.00 | 0.00 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | 9841.00 | 0.00 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | 6173.00 | 0.00 | 365 |
2016 | ROCKEFELLER OIL COMPANY LLC | 374.00 | 0.00 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 58 |
2006 | GREAT PLAINS EXPLORATION LLC | Brine | 680 | 365 |
2007 | GREAT PLAINS EXPLORATION LLC | Brine | 550 | 365 |
2008 | GREAT PLAINS EXPLORATION LLC | Brine | 950 | 365 |
2009 | GREAT PLAINS EXPLORATION LLC | Brine | 620 | 365 |
2010 | GREAT PLAINS EXPLORATION LLC | Brine | 520 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | Brine | 480 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | Brine | 400 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | Brine | 310 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | Brine | 210 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | Brine | 462 | 365 |
2016 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1026065217 | 2005-11-5 0:00: | DD | No Violations | |
-1378198055 | 2009-4-6 0:00:0 | PW | No Violations | |
-1805734383 | 2017-4-6 0:00:0 | UP | No Violations | 0.50 |
-454397941 | 2013-7-15 0:00: | UP | No Violations | |
-513470475 | 2016-2-19 0:00: | UP | No Violations | 0.50 |
-538363718 | 2017-12-12 0:00 | UP | No Violations | 0.50 |
-586502797 | 2011-8-16 0:00: | UP | No Violations | |
-594776885 | 2019-11-4 0:00: | UP | No Violations | |
-754626116 | 2017-9-19 0:00: | UP | No Violations | 1.00 |
0454397941 | 2013-07-15 | UrbanProduction Wells | No Violations | The producing unit consists of a wellhead and mechanical plunger-lift unit and an aboveground storage tank (AST) battery with one steel 210-barrel production tank and mechanical separator. There are no enclosures. The unit ID is present and meets requirements. The loadouts are not locked. The battery secondary containment is good. I contacted Tim Reilly with Great Plains and advised about the need for locks on the loadouts. |
0513470475 | 2016-02-19 | UrbanProduction Wells | Violations Noted | I inspected this producing well as part of routine inspection activity. At the time of my inspection, I observed the following elements: a wellhead with mechanical plunger lift and tank battery consisting of one 210-barrel steel storage tank, with mechanical separator. The battery and wellhead are not enclosed. Fittings and connections are free from leakage. The tank lid was closed and sealed. The dedicated access road is in good condition. The load-line valves were not locked and must be secured with locks. The owner must remedy the following by 03/25/2016: secure the load-line valves with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
0538363718 | 2017-12-12 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The load-lines were no locked and secure. At the time of this inspection, I observed the following: the noted deficiencies remained. In addition, I noted that the wellhead and battery were not in enclosures as required. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance. |
0586502797 | 2011-08-16 | UrbanProduction Wells | No Violations | Lease road stable, gate is locked. Dike and spacing in compliance. ID sign posted. Vent hatches are installed and closed. No violations at this time. |
0754626116 | 2017-09-19 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: The load lines were noted to be unlocked and unsecure. At the time of this inspection, the load-line valves remained unsecure. In addition, the ID signage remained unchanged and had not been updated to reflect the change in ownership that had occurred in 2016. Repeated calls to the owner have not produced any demonstrable action or results. |
1026065217 | 2005-11-05 | Drill / Deepen / Reopen | No Violations | |
1181141171 | 2007-04-16 | Preliminary Restoration | No Violations | |
1217056005 | 2005-11-06 | Drill / Deepen / Reopen | No Violations | surface 85/8 |
1378198055 | 2009-04-06 | Production Wells | No Violations | no violation |
1416468820 | 2005-05-18 | Drill / Deepen / Reopen | No Violations | making location |
1425653476 | 2015-03-06 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. The well and battery are located in a residential area along Jackson Street in Painesville. The dedicated lease road adjacent to the house at the referenced address The wellhead plunger lift system and battery are located in an open area behind houses. The wellhead and battery are not in enclosures. Connections and fittings are secure and free from signs of leakage or problems. Load-outs are plugged and secure but are not locked which was noted and reported to Great Plains at the last inspection. Areas around the wellhead and battery are snow-covered at the time of this inspection. I notified Great Plains a second time about the need for locks at the load-out. I did not observe any evidence of impact relating to on-going production activity. |
1798642713 | 2005-05-23 | Drill / Deepen / Reopen | No Violations | Making location dug test pit hit water and sand. |
1805734383 | 2017-04-06 | UrbanProduction Wells | No Violations | I inspected this well location as a follow-up to a previously-issued Compliance Notice. At the time of this inspection, I found the following: Fittings and connections at the wellhead were secure and free from leakage. The tank battery was comprised of a 210-barrel steel production tank with separator unit located in the rear portion of a parcel which was largely undeveloped, but utilized for stockpiling of bricks and other debris. Load-lines remained unsecure with locks as required. The ID signage remains not updated to reflect the new owner. I contacted John Magnussen with David Oil and advised him about the continuing deficiency. He indicated that the items are being worked on as they are able. I contacted Richard Osborne Sr. with David Oil Co., and as of the date of this report, I have not received a response. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0513470475 | US-OH-125605 | 2016-04-27 | LOCKS |
For data sources see[9]