Well Details

Well ID: 34-085-21150
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Leroy Township
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: GRANITEO
License Status: Producing
License Date: 2005-04-20
Spud Date: 2005-05-13
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2005-05-16
Well Total Depth: 3448.00 ft
Configuration: Vertical
Latitude: 41.710000
Longitude: -81.140000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-04-20 Proposed Formations:CLINTON, Issued Date:4/20/2005, Expired Date:4/20/2006 6:00:00 AM, Drilling unit acres:30, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-05-13 RBDMS Rec
Completed 2005-05-16 RBDMS Rec
Reached Total Depth 2005-05-16 RBDMS Rec
Completion Report Received 2005-09-06 RBDMS Rec
Construction Permit Expires 2006-04-20 RBDMS Rec
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2005-11-03 3211 3233 16
3211 3233 16
3211 3233 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 450 Bbl 90000 500 GALLONS HCL ACID & 510M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 GREAT PLAINS EXPLORATION LLC 2835.00 295.00 135
2006 GREAT PLAINS EXPLORATION LLC 3306.00 415.00 365
2007 GREAT PLAINS EXPLORATION LLC 2435.00 171.00 365
2008 GREAT PLAINS EXPLORATION LLC 2294.00 222.00 365
2009 GREAT PLAINS EXPLORATION LLC 2436.00 152.00 365
2010 GREAT PLAINS EXPLORATION LLC 2687.00 224.00 365
2011 GREAT PLAINS EXPLORATION LLC 2428.00 86.00 365
2012 GREAT PLAINS EXPLORATION LLC 2273.00 98.00 366
2013 GREAT PLAINS EXPLORATION LLC 1994.00 41.00 365
2014 GREAT PLAINS EXPLORATION LLC 1398.00 0.00 365
2015 GREAT PLAINS EXPLORATION LLC 1234.00 0.00 365
2016 ROCKEFELLER OIL COMPANY LLC 823.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 GREAT PLAINS EXPLORATION LLC Brine 240 135
2006 GREAT PLAINS EXPLORATION LLC Brine 1000 365
2007 GREAT PLAINS EXPLORATION LLC Brine 1120 365
2008 GREAT PLAINS EXPLORATION LLC Brine 880 365
2009 GREAT PLAINS EXPLORATION LLC Brine 640 365
2010 GREAT PLAINS EXPLORATION LLC Brine 560 365
2011 GREAT PLAINS EXPLORATION LLC Brine 400 365
2012 GREAT PLAINS EXPLORATION LLC Brine 400 366
2013 GREAT PLAINS EXPLORATION LLC Brine 160 365
2014 GREAT PLAINS EXPLORATION LLC Brine 0 365
2015 GREAT PLAINS EXPLORATION LLC Brine 0 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1170232162 2019-3-26 0:00: PW No Violations
-1217965747 2005-5-17 0:00: DD No Violations
-1347324385 2005-5-13 0:00: DD No Violations
-1414385756 2005-5-11 0:00: DD No Violations
-162476674 2017-9-12 0:00: UP No Violations 0.50
-2098651 2011-4-14 0:00: PL No Violations
-332797386 2005-7-11 0:00: PW No Violations
0002098651 2011-04-14 Preliminary Restoration No Violations Preliminary restoration passed.
0162476674 2017-09-12 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the load-lines were no secured with locks. At the time of this inspection, the indicated deficiency had been remedied. However, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership, and the fence enclosure at the wellhead remains broken down. Repeated calls to the owner have not produced any demonstrable action or results on these items.
0332797386 2005-07-11 Production Wells No Violations Area being graded for seeding.
0616650128 2009-08-03 Production Wells No Violations There were no violations.
0699607597 2017-12-13 Production Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The wellhead enclosure was not secure and required a lock. At the time of this inspection, I observed the following: the wellhead enclosure gate was locked. There was no visible or compliant signage. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance.
0783173798 2016-01-26 Production Wells Violations Noted I inspected this producing well as part of routine inspection activity. The well and battery are located in a generally sparsely developed, rural, residential area. Access to the well is afforded by a dedicated, unpaved access road. At the time of this inspection, I observed the following elements: a wellhead with pump jack system, a tank battery comprised of one 210-barrel steel production tank, one 100-barrel steel brine tank, and separator. The individual elements were housed in separate board-on-board enclosures. The load-outs were bull-plugged and secure. Secondary containment is intact. I observed the following maintenance issues: the ID signage is not clearly visible on the outside of the enclosure. The enclosure gate at the wellhead is broken and not secure. The owner must remedy the following by 04/04/2016: Fix the well enclosure and secure with a lock. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
1117211520 2005-05-14 Completion Testing No Violations BOP test passed.
1170232162 2019-03-26 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice # 1526921708, regarding the well enclosure needing secured with a lock. At the time of this inspection, the fenced well enclosure man doors, were secured with a lock. The well was not in production at the time of this inspection. Compliance notice closed.
1217965747 2005-05-17 Drill / Deepen / Reopen No Violations rig moving to paine rd,P#1137
1314799263 2011-08-31 Preliminary Restoration No Violations Lease road stable. ID sign in place. Dike, spacing, vent hatches, feedlines in compliance. Site passes Preliminary Restoration.
1347324385 2005-05-13 Drill / Deepen / Reopen No Violations surface and BOP permit condtion.
1352142959 2012-11-01 Preliminary Restoration No Violations The producing unit consists of a 2-tank battery (TB) in a 6-foot wood-slat enclosure. The unit spacing is in accordance with the rule, and the valving and mechanicals are in good repair. The mechanical separator is located within a separate 6-foot wood enclosure. The wellhead is fitted with a pump jack and is enlcosed within a separate 8-foot wood enclosure. The gates to the enclosures are all locked. The tank battery dike is in good condition. I did not observe any signs of leaking product or gas vapors. The unit ID is good. No violations noted.
1414385756 2005-05-11 Drill / Deepen / Reopen No Violations site graded for rig pits dug (shale)checked distance to house approx 130 BOP
1476728578 2012-11-02 Production Wells No Violations The unit is comprised of a two-tank battery (1 210-barrel production and 1 100-barrel brine). The wellhead includes a pumpjack. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . Unit identification is present and legible at the tank battery. I did not observe any leaks, spills, or other signs of contamination. No violations noted.
1526921708 2018-05-22 Production Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The wellhead enclosure was not secure and required a lock. At the time of this inspection, I observed the following: the wellhead enclosure gate was locked. There was no visible or compliant signage. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance. The well was not in active production.
616650128 2009-8-3 0:00:0 PW No Violations
699607597 2017-12-13 0:00 PW No Violations 0.50
783173798 2016-1-26 0:00: PW No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0783173798 US-OH-128905 2016-06-01 Failure to have required locks, bull plugs

For data sources see[9]