If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21151 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.65,"lon":-81.37,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: ROCKEFELLER OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: OTTAR | |
License Status: Producing | |
License Date: 2018-04-25 | |
Spud Date: 2005-10-28 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2005-11-04 | |
Well Total Depth: 3277.00 ft | |
Configuration: Vertical | |
Latitude: 41.650000 | |
Longitude: -81.370000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2005-05-23 | Proposed Formations:CLINTON, Issued Date:5/23/2005, Expired Date:5/23/2006 6:00:00 AM, Drilling unit acres:26.44, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2005-10-28 | RBDMS Rec UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. |
Completed | 2005-11-04 | RBDMS Rec UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. |
Reached Total Depth | 2005-11-04 | RBDMS Rec UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. |
Completion Report Received | 2006-03-21 | RBDMS Rec UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. |
Correction to Well | 2006-05-05 | CHANGE IN UNIT SIZE TO 20.22 ACRES. |
Change of Owner | 2016-12-05 | Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC |
APP | 2018-04-25 | Proposed Formations:CLINTON, Issued Date:4/25/2018, Expired Date:4/24/2020 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class: |
Record Last Modified | 2018-05-21 | RBDMS Rec UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. |
Construction Permit Expires | 2020-04-24 | RBDMS Rec UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-06-14 | 3049 | 3086 | 15 |
3049 | 3086 | 15 | |
3049 | 3086 | 15 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 436 Bbl | 90000 | 436M SCF NITROGEN ASSIST |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | GREAT PLAINS EXPLORATION LLC | 4887.00 | 0.00 | 49 |
2006 | GREAT PLAINS EXPLORATION LLC | 25385.00 | 67.00 | 365 |
2007 | GREAT PLAINS EXPLORATION LLC | 14983.00 | 42.00 | 365 |
2008 | GREAT PLAINS EXPLORATION LLC | 11813.00 | 27.00 | 365 |
2009 | GREAT PLAINS EXPLORATION LLC | 13210.00 | 0.00 | 365 |
2010 | GREAT PLAINS EXPLORATION LLC | 8211.00 | 0.00 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | 9210.00 | 9.00 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | 9080.00 | 0.00 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | 8554.00 | 0.00 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | 8046.00 | 0.00 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | 5605.00 | 0.00 | 365 |
2016 | ROCKEFELLER OIL COMPANY LLC | 564.00 | 0.00 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 49 |
2006 | GREAT PLAINS EXPLORATION LLC | Brine | 620 | 365 |
2007 | GREAT PLAINS EXPLORATION LLC | Brine | 200 | 365 |
2008 | GREAT PLAINS EXPLORATION LLC | Brine | 240 | 365 |
2009 | GREAT PLAINS EXPLORATION LLC | Brine | 290 | 365 |
2010 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | Brine | 240 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | Brine | 160 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | Brine | 160 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | Brine | 80 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | Brine | 160 | 365 |
2016 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1113554821 | 2009-12-2 0:00: | PW | No Violations | |
-1246446018 | 2017-9-1 0:00:0 | UP | No Violations | 0.50 |
-1623169524 | 2006-4-26 0:00: | PW | No Violations | |
-1918070642 | 2017-7-11 0:00: | UP | No Violations | 1.00 |
-729666179 | 2020-6-16 0:00: | UP | No Violations | |
0374671345 | 2013-09-10 | UrbanPreliminary Restoration | No Violations | The producing unit consists of a wellhead with pumpjack system and aboveground storage tank battery. The battery, separator, and wellhead are in separate board-on-board enclosures. The battery is comprised of 1 210-barrel steel production tank, one 100-barrel steel brine tank, and separator unit. There is adequate secondary containment. There is no safety equipment as required by 1501:9-9-05E. Locks and signage are present. No signs of leaks, spills or problems. Preliminary restoration is pending the installation of safety equipment. |
0549237256 | 2016-02-17 | UrbanProduction Wells | Violations Noted | I inspected this well as part of routine inspection activity. At the time of my inspection I observed the following elements: a wellhead with mechanical plunger lift system, mechanical separator, and tank battery comprised of one 210-barrel, and one 100-barrel, steel storage tanks. The battery and wellhead were enclosed in separate board-on-board enclosures which were unlocked. Fittings and connections at the wellhead and battery were secure and free from signs of leakage or problems with the following exception: the tank load lines were not secured with locks as required. The owner must remedy the following by 03/25/2016: secure the load-line valves and enclosure gates with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
1113554821 | 2009-12-02 | Production Wells | No Violations | A fix on the tank battery location was obtained. There were no violations. |
1246446018 | 2017-09-01 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the load-lines were no secured with locks. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress. |
1357229771 | 2012-12-17 | UrbanProduction Wells | No Violations | The unit is comprised of a two-tank battery (1 210-barrel production and 1 100-barrel brine) and a wellhead with mechanical plunger lift, and mechanical separator, each in separate wood board-on-board enclosures. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . Unit identification is present and legible at the tank battery. The tank battery secondary containment is adequate although the dike drain is open. I did not observe any leaks, spills, or other signs of contamination. The gates are locked. I called Tim Reilly with Great Plains and advised him about the open dike drain. He advised that the item would be addressed by the pumper. |
1512569104 | 2017-12-06 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves and enclosure gates were not locked. At the time of this inspection, I observed the following: there were no locks at the load-line valves and wellhead enclosure gates. In addition, the ID signage has not been updated to reflect the change of ownership that occurred over 12 months prior to this inspection. The tank battery gate was missing board sections and the wellhead enclosure was partially broken down. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance. |
1520600702 | 2018-03-08 | UrbanProduction Wells | No Violations | I inspected this well location as an evaluation of current status following the issuance of a compliance notice for missing locks on load-line valves and enclosure gates. At the time of this inspection, I observed the following: the load-line valves and well enclosure gate remained unlocked. In addition, the ID signage reflects prior ownership, and not updated to show the current owner information. To date, the owner has not remedied the deficiencies and not provided the division with a schedule for when they will return to compliance. |
1623169524 | 2006-04-26 | Production Wells | No Violations | well not ready for perl restoration area graded |
1918070642 | 2017-07-11 | UrbanProduction Wells | No Violations | I inspected this producing well location as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had noted the following: the tank battery enclosure was partially broken down, with a missing section. The load-line valves remain unsecured with locks. That condition remains at the time of this inspection. Also, I noted that the ID signage reflects the prior owner and remains not-updated since the transfer of ownership in 12/2016. |
1936959199 | 2005-10-30 | Drill / Deepen / Reopen | No Violations | surface |
374671345 | 2013-9-10 0:00: | UL | No Violations | |
398198765 | 2019-7-1 0:00:0 | UP | No Violations | |
549237256 | 2016-2-17 0:00: | UP | No Violations | 0.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0549237256 | US-OH-126045 | 2016-04-27 | LOCKS |
For data sources see[9]