If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21176 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.62,"lon":-81.4,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: ROCKEFELLER OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: GABRIELLE | |
License Status: Producing | |
License Date: 2005-10-19 | |
Spud Date: 2006-01-24 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2006-01-28 | |
Well Total Depth: 3272.00 ft | |
Configuration: Vertical | |
Latitude: 41.620000 | |
Longitude: -81.400000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2005-10-19 | Proposed Formations:CLINTON, Issued Date:10/19/2005, Expired Date:10/19/2006 6:00:00 AM, Drilling unit acres:55, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2006-01-24 | RBDMS Rec |
Completed | 2006-01-28 | RBDMS Rec |
Reached Total Depth | 2006-01-28 | RBDMS Rec |
Change of Owner | 2006-04-06 | Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 7909, JOHN D OIL & GAS COMPANY |
Completion Report Received | 2006-04-10 | RBDMS Rec |
Construction Permit Expires | 2006-10-19 | RBDMS Rec |
Change of Owner | 2016-12-14 | Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-10-30 | 2965 | 2975 | 13 |
2965 | 2975 | 13 | |
2965 | 2975 | 13 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 21000 Gal | 100000 | 638M SCF NITROGEN ASSIST |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | JOHN D OIL & GAS COMPANY | 612.00 | 0.00 | 82 |
2007 | JOHN D OIL & GAS COMPANY | 2365.00 | 51.00 | 365 |
2008 | JOHN D OIL & GAS COMPANY | 1168.00 | 0.00 | 365 |
2009 | JOHN D OIL & GAS COMPANY | 1362.00 | 52.00 | 365 |
2010 | JOHN D OIL & GAS COMPANY | 0.00 | 0.00 | 365 |
2011 | JOHN D OIL & GAS COMPANY | 2448.00 | 0.00 | 365 |
2012 | JOHN D OIL & GAS COMPANY | 2146.00 | 0.00 | 366 |
2013 | JOHN D OIL & GAS COMPANY | 1955.00 | 0.00 | 365 |
2014 | JOHN D OIL & GAS COMPANY | 1205.00 | 0.00 | 365 |
2015 | JOHN D OIL & GAS COMPANY | 0.00 | 0.00 | 0 |
2016 | JOHN D OIL & GAS COMPANY | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | JOHN D OIL & GAS COMPANY | Brine | 0 | 82 |
2007 | JOHN D OIL & GAS COMPANY | Brine | 390 | 365 |
2008 | JOHN D OIL & GAS COMPANY | Brine | 80 | 365 |
2009 | JOHN D OIL & GAS COMPANY | Brine | 560 | 365 |
2010 | JOHN D OIL & GAS COMPANY | Brine | 0 | 365 |
2011 | JOHN D OIL & GAS COMPANY | Brine | 0 | 365 |
2012 | JOHN D OIL & GAS COMPANY | Brine | 0 | 366 |
2013 | JOHN D OIL & GAS COMPANY | Brine | 0 | 365 |
2014 | JOHN D OIL & GAS COMPANY | Brine | 0 | 365 |
2015 | JOHN D OIL & GAS COMPANY | Brine | 0 | 0 |
2016 | JOHN D OIL & GAS COMPANY | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1136789971 | 2007-3-22 0:00: | PW | No Violations | |
-1249963542 | 2012-10-25 0:00 | UP | No Violations | |
-1321259036 | 2006-2-6 0:00:0 | DD | No Violations | |
-1865921040 | 2016-2-29 0:00: | UP | No Violations | 0.50 |
-935598360 | 2019-3-4 0:00:0 | UP | No Violations | |
0935598360 | 2019-03-04 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1865921040, regarding the need for locks to be installed on the production tank valve and the identification needing updated to reflect current ownership. At the time of this inspection, the identification has not been updated to include the current company information and the lock on the production tank valve has not been installed. I contacted David Oil Company, LLC, regarding the above compliance issues related to updated identification and installation of the tank valve lock and spoke with the office personnel, who stated they would pass the message to the field superintendent. |
1136789971 | 2007-03-22 | Production Wells | No Violations | checking dike called company to add move dike |
1249963542 | 2012-10-25 | UrbanProduction Wells | No Violations | The unit consists of a 1-tank battery with mechanical separator in an 8-foot wooden fence. The spacing is in accordance with the rule, and the valves and mechanicals are in good repair. The dike is adequate. I did not observe any signs of leaking product or gas vapors. The wellhead is fitted with a pumpjack and is enclosed in a 6-foot wooden fence. The well is currently shut-in. The lease road is in good repair. There is a locked gate at the head of the lease road. |
1261351810 | 2009-11-05 | Production Wells | No Violations | There were no violations at the time of inspection. |
1321259036 | 2006-02-06 | Drill / Deepen / Reopen | No Violations | site inspection |
1450153069 | 2017-04-17 | UrbanProduction Wells | No Violations | I inspected this well location as a follow-up to a previously-issued compliance notice for the following: missing locks at the load-line valves. At the time of this inspection, I observed the following: The load-line valves were not secured with locks. In addition, the ID signage has not been upgraded to reflect the change in ownership and is missing information required under OAC 1501:9-9-05(E)(1). I have contacted John Magnussen about the unaddressed deficiencies and he advised that the compliance issues are being tended to as soon as possible. I also attempted to contact Richard Osborne Sr. and, as of the filing of this report, he has not responded to multiple messages. |
1518794788 | 2018-02-16 | UrbanProduction Wells | No Violations | I inspected this well location as a follow-up to a previously-issued compliance notice for the following: missing locks at the load-line valves. At the time of this inspection, I observed the following: The load-line valves were not secured with locks. In addition, the ID signage had not been upgraded to reflect the change in ownership and was missing information required under OAC 1501:9-9-05(E)(1). I have contacted and met with the owner regarding these deficiencies. The owner has pledged to remedy the problems, but no changes were noted at the time of this inspection. The deficiencies remained. |
1865921040 | 2016-02-29 | UrbanProduction Wells | Violations Noted | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following elements: one wellhead with pump jack system in a board-on-board enclosure, one mechanical separator in a board-on-board enclosure, a tank battery comprised of one 210-barrel steel tank with associated fittings and tubular connections in a board-on-board enclosure. I observed the system fittings and connections to be secure and free from leakage. The tank lids were closed and secure. Spark arrestor, low-pressure relief valve, and carbon filter were present. Secondary containment was intact. I walked the areas surrounding the wellhead and battery and did not observe any evidence of impact or erosional deficits. Access to the well is afforded by a short dedicated, unpaved access road which enters from Waite Hill Road. At the time of this inspection, the road was in good condition. I observed the following safety deficiency: the wellhead enclosure gate was not locked and secure, the load-lines valve was not locked as required. The owner must remedy the following by 03/31/2016: secure the enclosure gates and load-lines with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
1882135186 | 2006-11-29 | Preliminary Restoration | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1865921040 | US-OH-118690 | 2016-04-27 | LOCKS |
For data sources see[9]