34-085-21178

Well Details

Well ID: 34-085-21178
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: ANDREWS SCHOOL/LORETTO UNIT
License Status: Producing
License Date: 2005-10-24
Spud Date: 2006-09-16
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2006-09-22
Well Total Depth: 3245.00 ft
Configuration: Vertical
Latitude: 41.630000
Longitude: -81.390000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-10-24 Proposed Formations:CLINTON, Issued Date:10/24/2005, Expired Date:10/24/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2006-09-22 RBDMS Rec
Reached Total Depth 2006-09-22 RBDMS Rec
Construction Permit Expires 2006-10-24 RBDMS Rec
Completion Report Received 2006-12-22 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-03-01 3014 3074 60
3014 3074 60
3014 3074 60

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 74580 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 ALLIANCE PETROLEUM CORPORATION 4785.00 17.00 365
2008 ALLIANCE PETROLEUM CORPORATION 24310.00 150.00 365
2009 ALLIANCE PETROLEUM CORPORATION 29264.00 166.00 365
2010 ALLIANCE PETROLEUM CORPORATION 6522.00 107.00 365
2011 ALLIANCE PETROLEUM CORPORATION 1039.00 0.00 365
2012 ALLIANCE PETROLEUM CORPORATION 740.00 63.00 366
2013 ALLIANCE PETROLEUM CORPORATION 632.00 18.00 365
2014 ALLIANCE PETROLEUM CORPORATION 648.00 10.00 365
2015 ALLIANCE PETROLEUM CORPORATION 536.00 18.00 365
2016 ALLIANCE PETROLEUM CORPORATION 530.00 22.00 365
2017 ALLIANCE PETROLEUM CORPORATION 1343.00 41.00 365
2018 ALLIANCE PETROLEUM CORPORATION 1828.00 55.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2008 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2009 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2010 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2011 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2012 ALLIANCE PETROLEUM CORPORATION Brine 0 366
2013 ALLIANCE PETROLEUM CORPORATION Brine 77 365
2014 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2015 ALLIANCE PETROLEUM CORPORATION Brine 27 365
2016 ALLIANCE PETROLEUM CORPORATION Brine 91 365
2017 ALLIANCE PETROLEUM CORPORATION Brine 289 365
2018 ALLIANCE PETROLEUM CORPORATION Brine 237 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1676081808 2011-3-22 0:00: PW No Violations
-392089740 2019-7-1 0:00:0 UP No Violations
-591676182 2010-7-23 0:00: PL No Violations
-613981817 2012-8-7 0:00:0 UP No Violations
0171713974 2011-06-13 UrbanProduction Wells No Violations Fencing in place, gate locked. Tank battery contains 2-100 bbl production tanks and mechanical seperator. Dike is good, spacing is good. Lighting arrestor and charcoal filter in place. Vent hatches in place and closed. Lease road is stable. Wellhead is a rabbit well in good repair, wellhead is fenced and locked.
0201235448 2013-07-16 UrbanPreliminary Restoration No Violations The producing unit consists of a wellhead and mechanical plunger-lift unit and an aboveground storage tank (AST) battery with one steel 140-barrel production tank, one steel 20-barrel brine tank, mechanical separator, and metering run.. The unit ID is present and meets requirements. The loadouts are bull-plugged. The battery secondary containment is good. The wellhead and battery are in separate chain-link enclosures. The tank battery is shared with the #3 Unit (3408521159). Safety equipment is present in accordance with 1501:9-9-05E. I did not observe any evidence of leakage or spills.
0591676182 2010-07-23 Preliminary Restoration No Violations Preliminary restoration was completed.
0613981817 2012-08-07 UrbanProduction Wells No Violations The unit is comprised of a two-tank battery and wellhead with mechanical lift. The well is currently in production. The unit #2 wellhead is located 150 feet to the west. The tank battery is shared by the #1 unit, which consists of a pumping unit located 800 feet north of the tank battery. The tank and well spacing is in accordance with 1509:9-9-05. Unit identification is present and legible. The tank battery dike is good condition. The load outs need a means of secondary containment. I did not observe any leaks, spills, or other signs of contamination. Spark arrestors, low-pressure relief valves, and charcoal canister are present as required by HB 278. The charcoal canister is rusted on the bottom and needs serviced or changed out. I called Bruce Close and asked him to tend to the maintenance issues. I am waiting to hear back from him.
1489761431 2017-03-17 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection I observed the following: a wellhead with plunger lift system and associated battery located on property owned by the Andrews Osborne school, along the east side of the Chagrin River. There is a dedicated, gravel-paved access road that enters from Ridge Road, and provides access to both the #2-1177 and #2-1178 wells. The access road was well drained and in good condition. Access gates were locked and secure. The load-line valves were closed but were not locked. I also observed that the carbon filter canister was severely coroded and the granular carbon material was spilling out of the canister. Tank lids were closed and secure. I walked the areas around the wellhead and battery and found the natural conditions intact with no signs of impact or problems. I contacted well tender Matt Postelwaite and advised about the need for locks and replacement of the carbon vapor filter. He indicated that the repairs would be made within the week.
1676081808 2011-03-22 Production Wells No Violations No violations were found at the time.
171713974 2011-6-13 0:00: UP No Violations 0.50
201235448 2013-7-16 0:00: UL No Violations

For data sources see[9]

References