If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21191 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.68,"lon":-81.2,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Concord Township | |
Operator Name: DAVID OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: JR | |
License Status: Producing | |
License Date: 2006-01-30 | |
Spud Date: 2006-03-04 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2006-03-08 | |
Well Total Depth: 3336.00 ft | |
Configuration: Vertical | |
Latitude: 41.680000 | |
Longitude: -81.200000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2006-01-30 | Proposed Formations:CLINTON, Issued Date:1/30/2006, Expired Date:1/30/2007 6:00:00 AM, Drilling unit acres:20.493, Proposed Well Type:OG, Proposed Well Class:EOUT |
Original Spud | 2006-03-04 | RBDMS Rec |
Completed | 2006-03-08 | RBDMS Rec |
Reached Total Depth | 2006-03-08 | RBDMS Rec |
Completion Report Received | 2006-05-08 | RBDMS Rec |
Construction Permit Expires | 2007-01-30 | RBDMS Rec |
Change of Owner | 2016-12-14 | Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-07-27 | 3131 | 3138 | 16 |
3131 | 3138 | 16 | |
3131 | 3138 | 16 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 526 Bbl | 120000 | 689M SCF NITROGEN ASSIST |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | JOHN D OIL & GAS COMPANY | 6631.00 | 0.00 | 274 |
2007 | JOHN D OIL & GAS COMPANY | 8795.00 | 136.00 | 365 |
2008 | JOHN D OIL & GAS COMPANY | 4003.00 | 42.00 | 365 |
2009 | JOHN D OIL & GAS COMPANY | 3641.00 | 59.00 | 365 |
2010 | JOHN D OIL & GAS COMPANY | 2854.00 | 0.00 | 365 |
2011 | JOHN D OIL & GAS COMPANY | 2238.00 | 0.00 | 365 |
2012 | JOHN D OIL & GAS COMPANY | 2479.00 | 0.00 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | 2109.00 | 0.00 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | 2034.00 | 0.00 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | 2409.00 | 0.00 | 365 |
2016 | DAVID OIL COMPANY LLC | 305.00 | 0.00 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | JOHN D OIL & GAS COMPANY | Brine | 670 | 274 |
2007 | JOHN D OIL & GAS COMPANY | Brine | 1360 | 365 |
2008 | JOHN D OIL & GAS COMPANY | Brine | 720 | 365 |
2009 | JOHN D OIL & GAS COMPANY | Brine | 1200 | 365 |
2010 | JOHN D OIL & GAS COMPANY | Brine | 1020 | 365 |
2011 | JOHN D OIL & GAS COMPANY | Brine | 960 | 365 |
2012 | JOHN D OIL & GAS COMPANY | Brine | 560 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | Brine | 400 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | Brine | 510 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | Brine | 240 | 365 |
2016 | JOHN D OIL & GAS COMPANY | Brine | 80 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1608498642 | 2020-9-25 0:00: | UP | No Violations | |
-560832751 | 2017-12-13 0:00 | UP | No Violations | |
0560832751 | 2017-12-13 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The load lines were not locked and secure. At the time of this inspection, I observed the following: the load-line valves remained unlocked. In addition, the ID signage had not been updated to reflect the change of ownership that occurred in 2016. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance. |
1121578476 | 2016-03-02 | UrbanProduction Wells | Violations Noted | I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with mechanical plunger lift system located in a low, flat-lying area adjacent to Big Creek. A tank battery comprised of one 210-barrel steel production tank, one 100-barrel steel brine tank, and a mechanical separator is located in the upland area west of the creek. Fittings and connections were bull-plugged but not locked. Low-pressure relief valve, spark arrestor, and carbon filter were present. Fittings and connections at the wellhead were secure and free from signs of leakage or problems. The 8.625-inch casing was exposed but not gauged as required by specific permit condition. The owner must remedy the following by 04/03/2016: secure the load-line valves with locks. Expose and property gauge the 8.625-inch surface casing annulus as required by permit condition. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
1606007924 | 2011-12-13 | UrbanPreliminary Restoration | No Violations | The tank battery is equipped with one 210 barrel production tank, one 100 barrel brine tank and a heat treat separator. The equipment spacing is correct (50 between production tank and separator). Spacing is also correct between well and tank battery. This site falls under urban requirements. It is secluded and on the owner/operators property. The estate is gated and there is a stream crossing that isolates the well. The well is in a fenced field and the tank battery is in a wooded location. Urban requirements are waived at this time. If there is an ownership change Urban equipment will need to be installed. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1121578476 | US-OH-103077 | 2016-04-27 | LOCKS |
For data sources see[9]