{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.68,"lon":-81.2,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Concord Township | |
Operator Name: DAVID OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: HEIDNIK | |
License Status: Producing | |
License Date: 2006-01-30 | |
Spud Date: 2006-02-26 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2006-03-03 | |
Well Total Depth: 3380.00 ft | |
Configuration: Vertical | |
Latitude: 41.680000 | |
Longitude: -81.200000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2006-01-30 | Proposed Formations:CLINTON, Issued Date:1/30/2006, Expired Date:1/30/2007 6:00:00 AM, Drilling unit acres:22.859, Proposed Well Type:OG, Proposed Well Class:EOUT |
Original Spud | 2006-02-26 | RBDMS Rec |
Completed | 2006-03-03 | RBDMS Rec |
Reached Total Depth | 2006-03-03 | RBDMS Rec |
Completion Report Received | 2006-05-08 | RBDMS Rec |
Construction Permit Expires | 2007-01-30 | RBDMS Rec |
Change of Owner | 2016-12-14 | Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-07-27 | 3354 | 3373 | 15 |
3354 | 3373 | 15 | |
3354 | 3373 | 15 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 549 Bbl | 120000 | 675M SCF NITROGEN ASSIST |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | JOHN D OIL & GAS COMPANY | 10533.00 | 0.00 | 279 |
2007 | JOHN D OIL & GAS COMPANY | 3022.00 | 0.00 | 365 |
2008 | JOHN D OIL & GAS COMPANY | 2353.00 | 0.00 | 365 |
2009 | JOHN D OIL & GAS COMPANY | 2469.00 | 0.00 | 365 |
2010 | JOHN D OIL & GAS COMPANY | 2914.00 | 0.00 | 365 |
2011 | JOHN D OIL & GAS COMPANY | 2871.00 | 0.00 | 365 |
2012 | JOHN D OIL & GAS COMPANY | 2364.00 | 0.00 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | 1673.00 | 0.00 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | 1863.00 | 0.00 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | 746.00 | 0.00 | 365 |
2016 | DAVID OIL COMPANY LLC | 0.00 | 0.00 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | JOHN D OIL & GAS COMPANY | Brine | 860 | 279 |
2007 | JOHN D OIL & GAS COMPANY | Brine | 1680 | 365 |
2008 | JOHN D OIL & GAS COMPANY | Brine | 980 | 365 |
2009 | JOHN D OIL & GAS COMPANY | Brine | 1640 | 365 |
2010 | JOHN D OIL & GAS COMPANY | Brine | 1610 | 365 |
2011 | JOHN D OIL & GAS COMPANY | Brine | 1520 | 365 |
2012 | JOHN D OIL & GAS COMPANY | Brine | 1120 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | Brine | 645 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | Brine | 1005 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | Brine | 260 | 365 |
2016 | JOHN D OIL & GAS COMPANY | Brine | 0 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1251381476 | 2016-3-2 0:00:0 | UP | No Violations | 1.00 |
-798753794 | 2017-12-13 0:00 | UP | No Violations | 0.50 |
0798753794 | 2017-12-13 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The load lines were not locked and secure. At the time of this inspection, I observed the following: the load-line valves remained unlocked. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance. |
0819228959 | 2011-12-13 | Preliminary Restoration | No Violations | This well is in Concord Township which is covered by HB-278. The well is in a secluded area on the operators property. The property/estate is gated and you have to cross Big Creek stream to access the well. The lease road is stable. This well is equipped with a pumping unit. The well head and tank battery are not fenced or landscaped. The area affected from drilling has been reclaimed and the site is stable and in good repair. The tank battery is equipped with one 210 barrel tank, one 100 barrel tank and a heat treat separator. Equipment spacing is correct. The remote location of the well and the security of the property would have allowed for the waiver of the landscaping and fencing during the permitting process. Requirements are waived at this time. If there is an ownership change HB-278 equipment will need to be installed. |
1184953879 | 2020-9-25 0:00: | UP | No Violations | |
1251381476 | 2016-03-02 | UrbanProduction Wells | Violations Noted | I inspected this well as part of routine inspection activity. The well and battery are accessed via a dedicated, gravel-paved lease road that enters from Williams Road. The head of the lease road is gated. At the time of this inspection, I observed the following elements: a wellhead with pump jack system and, a tank battery comprised of one 210-barrel steel tank, one 100-barrel steel tank, a mechanical separator. Fittings and connections were bull-plugged but not locked. The owner must remedy the following by 04/08/2016: secure the load-line valves with locks. Place ID signage at the entry gate. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
819228959 | 2011-12-13 0:00 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1251381476 | US-OH-106736 | 2016-04-27 | ID (a-i) | |
1251381476 | US-OH-106737 | 2016-04-27 | LOCKS |
For data sources see[9]