{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.7,"lon":-81.19,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Leroy Township | |
Operator Name: ROCKEFELLER OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: JOSH | |
License Status: Producing | |
License Date: 2006-06-05 | |
Spud Date: 2006-12-06 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2006-12-09 | |
Well Total Depth: 3331.00 ft | |
Configuration: Vertical | |
Latitude: 41.700000 | |
Longitude: -81.190000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2006-06-05 | Proposed Formations:CLINTON, Issued Date:6/5/2006, Expired Date:6/5/2007 6:00:00 AM, Drilling unit acres:20.671, Proposed Well Type:OG, Proposed Well Class:EOUT |
Reached Total Depth | 2006-12-09 | RBDMS Rec |
Completion Report Received | 2007-03-16 | RBDMS Rec |
Construction Permit Expires | 2007-06-05 | RBDMS Rec |
Completed | 2007-12-09 | RBDMS Rec |
Change of Owner | 2016-12-05 | Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2007-07-03 | 3132 | 3181 | 24 |
3132 | 3181 | 24 | |
3132 | 3181 | 24 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 475 Bbl | 100000 | FRAC INCLUDED 575 MSCF OF N2 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | GREAT PLAINS EXPLORATION LLC | 19106.00 | 0.00 | 353 |
2008 | GREAT PLAINS EXPLORATION LLC | 11607.00 | 37.00 | 365 |
2009 | GREAT PLAINS EXPLORATION LLC | 7159.00 | 0.00 | 365 |
2010 | GREAT PLAINS EXPLORATION LLC | 5479.00 | 0.00 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | 3327.00 | 0.00 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | 3259.00 | 0.00 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | 3551.00 | 0.00 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | 3309.00 | 0.00 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | 715.00 | 0.00 | 365 |
2016 | ROCKEFELLER OIL COMPANY LLC | 0.00 | 0.00 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | GREAT PLAINS EXPLORATION LLC | Brine | 560 | 353 |
2008 | GREAT PLAINS EXPLORATION LLC | Brine | 1840 | 365 |
2009 | GREAT PLAINS EXPLORATION LLC | Brine | 1060 | 365 |
2010 | GREAT PLAINS EXPLORATION LLC | Brine | 1040 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | Brine | 1120 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | Brine | 800 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | Brine | 770 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | Brine | 560 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | Brine | 50 | 365 |
2016 | GREAT PLAINS EXPLORATION LLC | Brine | 80 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1280687960 | 2011-9-6 0:00:0 | UL | No Violations | |
-1329068810 | 2016-2-24 0:00: | PW | No Violations | 0.50 |
-1695582050 | 2018-7-13 0:00: | UP | No Violations | 1.00 |
-421070285 | 2020-4-20 0:00: | PW | No Violations | |
0723967101 | 2017-09-22 | Production Wells | No Violations | I inspected this producing well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system, with associated tank battery. The system is located in a clearing within a wooded area on a larger, undeveloped parcel. Fittings and connections were secure. I did note that the ID signage had not been changed or updated to reflect the change of ownership that had occurred in 2016. The owner has made repeated pledges to update the signage on the well but with no results. |
0925496504 | 2006-12-06 | Drill / Deepen / Reopen | No Violations | surface |
0974768341 | 2008-06-10 | Production Wells | No Violations | |
1280687960 | 2011-09-06 | UrbanPreliminary Restoration | No Violations | Site is Pre-HB 278. Dike, spacing, vent hatches, and ID are in compliance. Feedlines are bull plugged. This site passes Preliminary Restoration. |
1329002614 | 2010-09-02 | Production Wells | No Violations | No violations were found at the time of inspection. |
1329068810 | 2016-02-24 | Production Wells | No Violations | I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with mechanical plunger lift system and tank battery with one 210-barrel, and one 100-barrel, steel storage tank. I walked the areas around the wellhead and battery and did not observe any signs of impact relating to the on-going production activity. Access to the well and battery was afforded by a shared-use unpaved access road which was in good condition. |
1370019297 | 2013-05-31 | UrbanProduction Wells | Violations Noted | The producing unit consists of the following elements: a wellhead with pumpjack, and a tank battery system. There are no enclosures. The tank battery is comprised of one 210-barrel and one 100-barrel steel tank, and mechanical separator. Secondary containment is present at the tank battery. Unit spacing is in accordance with the regulations. There is no proper ID anywhere at the unit. I contacted and advised Tim Reilly with Great Plains about the need for proper signage. |
1695582050 | 2018-07-13 | UrbanProduction Wells | No Violations | I inspected th well as a follow-up to a previous Compliance Notice issued for missing identification. At the time of this inspection, the identification remained not updated to reflect the change of ownership that had occurred in 2015. The well was shut-in and not in active production. I noted that the 100-barrel steel brine tank exhibited severe corrosion and was in danger of failing. The tank should be replaced before returnoing the well to active production. |
723967101 | 2017-9-22 0:00: | PW | No Violations | 0.50 |
925496504 | 2006-12-6 0:00: | DD | No Violations | |
974768341 | 2008-6-10 0:00: | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1370019297 | US-OH-110920 | 2013-07-22 | ID (a-i) |
For data sources see[9]