If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21209 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.69,"lon":-81.24,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Concord Township | |
Operator Name: DAVID OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: HULDERMAN | |
License Status: Producing | |
License Date: 2006-06-19 | |
Spud Date: 2006-10-07 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2006-10-12 | |
Well Total Depth: 3327.00 ft | |
Configuration: Vertical | |
Latitude: 41.690000 | |
Longitude: -81.240000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2006-06-19 | Proposed Formations:CLINTON, Issued Date:6/19/2006, Expired Date:6/19/2007 6:00:00 AM, Drilling unit acres:21.966, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2006-10-12 | RBDMS Rec |
Reached Total Depth | 2006-10-12 | RBDMS Rec |
Completion Report Received | 2007-01-16 | RBDMS Rec |
Construction Permit Expires | 2007-06-19 | RBDMS Rec |
Change of Owner | 2016-12-14 | Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2007-03-27 | 3112 | 3140 | 26 |
3112 | 3140 | 26 | |
3112 | 3140 | 26 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 19484 Gal | 100000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | JOHN D OIL & GAS COMPANY | 3721.00 | 0.00 | 63 |
2007 | JOHN D OIL & GAS COMPANY | 12032.00 | 99.00 | 365 |
2008 | JOHN D OIL & GAS COMPANY | 6905.00 | 69.00 | 365 |
2009 | JOHN D OIL & GAS COMPANY | 6508.00 | 85.00 | 365 |
2010 | JOHN D OIL & GAS COMPANY | 5970.00 | 110.00 | 365 |
2011 | JOHN D OIL & GAS COMPANY | 5658.00 | 108.00 | 365 |
2012 | JOHN D OIL & GAS COMPANY | 6285.00 | 75.00 | 366 |
2013 | JOHN D OIL & GAS COMPANY | 5409.00 | 47.00 | 365 |
2014 | JOHN D OIL & GAS COMPANY | 2955.00 | 80.00 | 365 |
2015 | JOHN D OIL & GAS COMPANY | 1237.00 | 0.00 | 365 |
2016 | DAVID OIL COMPANY LLC | 309.00 | 0.00 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | JOHN D OIL & GAS COMPANY | Brine | 0 | 63 |
2007 | JOHN D OIL & GAS COMPANY | Brine | 1320 | 365 |
2008 | JOHN D OIL & GAS COMPANY | Brine | 640 | 365 |
2009 | JOHN D OIL & GAS COMPANY | Brine | 400 | 365 |
2010 | JOHN D OIL & GAS COMPANY | Brine | 400 | 365 |
2011 | JOHN D OIL & GAS COMPANY | Brine | 480 | 365 |
2012 | JOHN D OIL & GAS COMPANY | Brine | 560 | 366 |
2013 | JOHN D OIL & GAS COMPANY | Brine | 80 | 365 |
2014 | JOHN D OIL & GAS COMPANY | Brine | 160 | 365 |
2015 | JOHN D OIL & GAS COMPANY | Brine | 294 | 365 |
2016 | JOHN D OIL & GAS COMPANY | Brine | 0 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-397793879 | 2019-2-14 0:00: | UP | No Violations | 0.40 |
-425931807 | 2020-1-28 0:00: | UP | No Violations | 0.50 |
-492979818 | 2017-8-3 0:00:0 | UP | No Violations | 1.00 |
-596770434 | 2013-7-25 0:00: | UL | No Violations | |
0397793879 | 2019-02-14 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1599728658, regarding the installation of locks at the well and tank battery fence doors, locks on the tank valves, the installation of required urban production safety equipment, and the repair of the fencing around the wellhead. At the time of this inspection, the well was equipped with a plunger lift assembly and not in production. The fencing around the well has been repaired but still needed a lock installed on the fence door. The diked and fenced tank battery was comprised of two 100 BBL tanks, with a mechanical separator. The production tanks still needed the urban safety equipment installed, i.e. spark arrestor, a low-pressure relief valve, and a charcoal filter. The tank valves were not locked and needed the locks installed. Identification was present. Lease access was stable. |
0492979818 | 2017-08-03 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice. At the time of the previous inspection, I had noted the following: the load-line valves were not secure with locks, the wellhead enclosure fence was partially torn down and the tanks were missing carbon filter and spark arrestor. At the time of this inspection, the noted deficiencies remain. I contacted John Magnussen with David Oil who indicated that the issues are being handled as they are able. I inspected the wellhead and surrounding area and found no signs of problems otherwise. |
0509566845 | 2009-09-10 | Preliminary Restoration | No Violations | Preliminary restoration was completed. |
0596770434 | 2013-07-25 | UrbanPreliminary Restoration | No Violations | The producing unit consists of a wellhead and mechanical plunger-lift and an aboveground storage tank (AST) battery with two steel 140-barrel production tanks, one poly 50-barrel brine tank, mechanical separator in separate chain-link enclosures. The unit ID is present nut is not visible outsice the enclosure. Tank spacing and meets requirements. The loadouts are locked. The battery secondary containment is good. No evidence of leaks or problems. The lease road is well maintained and the site is in good condition. Preliminary restoration passes. I talked to Tim Reilly about moving the tank ID to the outside for visibility. |
1161801235 | 2006-10-07 | Drill / Deepen / Reopen | No Violations | surface cementing |
1229687150 | 2014-10-02 | Production Wells | No Violations | I inspected the location of this producing unit as part of routine inspection activity. The well is currently producing. Production reports are current. The well and surrounding area are free from signs of leakage or problems. The tank battery secondary containment is intact. Load-outs are bull-plugged and the gates are locked. No problems noted. |
1293212120 | 2017-12-11 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: there was no spark arrestor, low-pressure relief valve, or carbon filter, the load-line valves were not locked and secure, and the fencing at the wellhead was partially missing. At the time of this inspection, I observed the following: the wellhead fencing was repaired. But the remaining deficiencies remained. In addition, the unit signage had not been updated since the change of owner that had occurred in 2016. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance. |
1599728658 | 2016-02-19 | UrbanProduction Wells | Violations Noted | I inspected this producing well as part of routine inspection activity. At the time of my inspection, I observed the following elements: a wellhead with mechanical plunger lift and tank battery consisting of two 100-barrel steel, low-profile storage tanks, with mechanical separator. The battery and wellhead were in in separate board-on-board enclosures. Fittings and connections were free from leakage. The production tanks did not have a spark arrestor, a low-pressure relief valve, or a carbon filter as required. The shared access road is in good condition. The enclosure gates were not locked or secure. The load-line valves were not locked and must be secured with locks. The owner must remedy the following by 04/01/2016: secure the load-line valves and enclosure gates with locks. Supply and correctly fit the production tank with carbon filter, low-pressure relief valve, and spark arrestor, repair the wellhead enclosure fence. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
509566845 | 2009-9-10 0:00: | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1599728658 | US-OH-115672 | 2016-04-27 | FENCING (a-d) | |
1599728658 | US-OH-115673 | 2016-04-27 | LOCKS | |
1599728658 | US-OH-115674 | 2016-04-27 | TANKS (a-i) |
For data sources see[9]