X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-21219

Well Details

Well ID: 34-085-21219
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: NEWELL CREEK
License Status: Producing
License Date: 2006-10-16
Spud Date: 2006-11-18
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-11-22
Well Total Depth: 3299.00 ft
Configuration: Vertical
Latitude: 41.650000
Longitude: -81.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-10-16 Proposed Formations:CLINTON, Issued Date:10/16/2006, Expired Date:10/16/2007 6:00:00 AM, Drilling unit acres:36.3031, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2006-11-22
Reached Total Depth 2006-11-22
Completion Report Received 2007-01-16
Construction Permit Expires 2007-10-16
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-03-27 3104 3128 23
3104 3128 23
3104 3128 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 20090 Gal 100000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 GREAT PLAINS EXPLORATION LLC 674.00 0.00 16
2007 GREAT PLAINS EXPLORATION LLC 24762.00 0.00 365
2008 GREAT PLAINS EXPLORATION LLC 24521.00 55.00 365
2009 GREAT PLAINS EXPLORATION LLC 21427.00 46.00 365
2010 GREAT PLAINS EXPLORATION LLC 13724.00 0.00 365
2011 GREAT PLAINS EXPLORATION LLC 11809.00 52.00 365
2012 GREAT PLAINS EXPLORATION LLC 9906.00 51.00 366
2013 GREAT PLAINS EXPLORATION LLC 8200.00 34.00 365
2014 GREAT PLAINS EXPLORATION LLC 8568.00 0.00 365
2015 GREAT PLAINS EXPLORATION LLC 7888.00 0.00 365
2016 ROCKEFELLER OIL COMPANY LLC 1678.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 GREAT PLAINS EXPLORATION LLC Brine 0 16
2007 GREAT PLAINS EXPLORATION LLC Brine 300 365
2008 GREAT PLAINS EXPLORATION LLC Brine 320 365
2009 GREAT PLAINS EXPLORATION LLC Brine 400 365
2010 GREAT PLAINS EXPLORATION LLC Brine 400 365
2011 GREAT PLAINS EXPLORATION LLC Brine 320 365
2012 GREAT PLAINS EXPLORATION LLC Brine 240 366
2013 GREAT PLAINS EXPLORATION LLC Brine 240 365
2014 GREAT PLAINS EXPLORATION LLC Brine 80 365
2015 GREAT PLAINS EXPLORATION LLC Brine 80 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1219664283 2017-12-6 0:00: UP No Violations 0.50
-1660621576 2014-7-29 0:00: UP No Violations
-1825895475 2019-5-1 0:00:0 UP No Violations
-1846396766 2010-4-23 0:00: PW No Violations
-2135536926 2016-2-18 0:00: UP No Violations 0.50
0084189666 2017-09-07 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: missing process safety equipment (low-pressure relief valve, spark arrestor, carbon filter) , the load-lines were not secured with locks. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress.
0228298244 2009-08-03 Preliminary Restoration No Violations
1167746785 2006-11-22 Drill / Deepen / Reopen No Violations drilling 3000
1219664283 2017-12-06 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked and the production tanks were missing process safety equipment (spark arrestor, low-pressure relief valve), and carbon filter as required. At the time of this inspection, I observed the following: there were no locks at the load-line valves or indicated process safety equipment. The ID signage had been updated. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance.
1492176364 2017-04-14 UrbanProduction Wells No Violations I inspected this producing well as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had noted that the load-line valves were not secure with locks as required. In addition, I had noted that the tanks were lacking the required process safety equipment (spark arrestor, low-pressure relief valve, carbon filter). At the time of this inspection, I observed the following: the access road to the well and battery, which is comprised of a gravel-paved road that enters from Norton Parkway and travels 300 feet to the well and battery, was in good condition with no drainage problems or wash-outs. The separate enclosure gates were locked and secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure and free from leakage. I walked the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features. I did observe the following maintenance and safety deficiencies; the load line valves remain unsecured with locks, the ID signage had not been updated to reflect the recent change in ownership, and the process safety equipment remains missing. I attempted to contact both company representatives John Magnussen and Richard Osborne and, as of the filing of this report, no representative of the company has responded.
1528998269 2018-06-14 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked and the production tanks were missing process safety equipment (spark arrestor, low-pressure relief valve), and carbon filter as required. At the time of this inspection, I observed the following: there were no locks at the load-line valves or indicated process safety equipment. The well was not in active production and there was not an active chart record. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance.
1553791168 2019-03-28 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice # 2135536926, regarding the missing urban safety equipment (low-pressure relief valve, spark arrestor, carbon filter), the load-lines needing secured with locks and updated identification relevant to current ownership information. At the time of this inspection, the load lines still needed locks installed and none of the urban safety equipment has been installed on the production tanks has been installed. The identification has been updated to reflect current owner information. The well was not in production and the valve on the tubing was open but the 2 inch flow line valve was closed. The well, mechanical separator, and production tanks were surrounded with board on board fencing and secured with locks on the man doors. I contacted Rockefeller Oil Co. and spoke with Jenny Corrao regarding the locks for tank valves needing installed and installing the urban safety equipment on the production tanks.
1591108925 2020-6-2 0:00:0 UP No Violations
1660621576 2014-07-29 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 11/22/2006. The unit is producing and production reports are current. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger-lift system and aboveground storage tank (AST) battery. The wellhead and battery are accessed via a dedicated gravel access road which travels north from Norton Parkway, to a low-lying area behind a newer residential development. The aboveground storage tank (AST) battery is located 60 feet to the south of the well in a separate board-on-board enclosure. The battery is comprised of a total of 1 steel 100-barrel production tank and 1 steel 100-barrel brine tank, and horizontal separator in a 3rd, separate, locked enclosure. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-outs are bull-plugged. The secondary containment at the battery is present but very low and not adequate to contain a release. I did not observe any signs or evidence of leakage, spills, or problems. There is ID signage at the battery which is legible and in good condition. The area surrounding the wellhead slopes to the west towards Newell Creek which is 100 feet west-southwest of the unit. I did not observe any signs of drainage or erosional deficits associated with the unit. I notified Great Plains about the containment dike deficiency.
1846396766 2010-04-23 Production Wells No Violations There were no violations at the time of inspection.
2135536926 2016-02-18 UrbanProduction Wells Violations Noted I inspected this producing well as part of routine inspection activity. At the time of my inspection, I observed the following elements: a wellhead with mechanical plunger lift and tank battery consisting of two 100-barrel steel, low-profile storage tanks, with mechanical separator. The battery and wellhead were in in separate board-on-board enclosures. Fittings and connections are free from leakage. The production tanks did not have a spark arrestor, a low-pressure relief valve, or a carbon filter as required. The dedicated access road is in good condition. The enclosure gates were locked and secure. The load-line valves were not locked and must be secured with locks. The owner must remedy the following by 04/01/2016: secure the load-line valves and enclosure gates with locks. Supply and correctly fit the production tank with carbon filter, low-pressure relief valve, and spark arrestor. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
228298244 2009-8-3 0:00:0 PL No Violations
84189666 2017-9-7 0:00:0 UP No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
2135536926 US-OH-121884 2016-04-27 LOCKS
2135536926 US-OH-121885 2016-04-27 TANKS (a-i)

For data sources see[9]