If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21224 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.68,"lon":-81.24,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Concord Township | |
Operator Name: DAVID OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: LAKE COUNTY FARMERS | |
License Status: Producing | |
License Date: 2006-11-01 | |
Spud Date: 2006-12-12 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2006-12-22 | |
Well Total Depth: 3280.00 ft | |
Configuration: Vertical | |
Latitude: 41.680000 | |
Longitude: -81.240000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2006-11-01 | Proposed Formations:CLINTON, Issued Date:11/1/2006, Expired Date:11/1/2007 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2006-12-22 | |
Reached Total Depth | 2006-12-22 | |
Completion Report Received | 2007-01-31 | |
Construction Permit Expires | 2007-11-01 | |
Change of Owner | 2017-10-06 | Operator changed from 169, JAMES R SMAIL INC to 9836, DAVID OIL COMPANY LLC |
Record Last Modified | 2017-10-06 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2007-04-12 | 3087 | 3097 | 11 |
2007-04-12 | 3104 | 3107 | 4 |
3087 | 3097 | 11 | |
3104 | 3107 | 4 | |
3121 | 3122 | 2 | |
3087 | 3097 | 11 | |
2007-04-12 | 3121 | 3122 | 2 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 18720 Gal | 80000 | 600 MSCF OF N2 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | JAMES R SMAIL INC | 1924.00 | 53.00 | 270 |
2008 | JAMES R SMAIL INC | 1910.00 | 90.00 | 270 |
2009 | JAMES R SMAIL INC | 2774.00 | 0.00 | 270 |
2010 | JAMES R SMAIL INC | 3164.00 | 0.00 | 270 |
2011 | JAMES R SMAIL INC | 3614.00 | 0.00 | 365 |
2012 | JAMES R SMAIL INC | 2564.00 | 0.00 | 366 |
2013 | JAMES R SMAIL INC | 4088.00 | 0.00 | 365 |
2014 | JAMES R SMAIL INC | 3746.00 | 0.00 | 365 |
2015 | JAMES R SMAIL INC | 937.00 | 0.00 | 365 |
2016 | JAMES R SMAIL INC | 917.00 | 0.00 | 365 |
2017 | JAMES R SMAIL INC | 2637.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | JAMES R SMAIL INC | Brine | 1360 | 270 |
2008 | JAMES R SMAIL INC | Brine | 0 | 270 |
2009 | JAMES R SMAIL INC | Brine | 880 | 270 |
2010 | JAMES R SMAIL INC | Brine | 0 | 270 |
2011 | JAMES R SMAIL INC | Brine | 375 | 365 |
2012 | JAMES R SMAIL INC | Brine | 400 | 366 |
2013 | JAMES R SMAIL INC | Brine | 480 | 365 |
2014 | JAMES R SMAIL INC | Brine | 0 | 365 |
2015 | JAMES R SMAIL INC | Brine | 0 | 365 |
2016 | JAMES R SMAIL INC | Brine | 0 | 365 |
2017 | JAMES R SMAIL INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1733177752 | 2006-12-20 0:00 | DD | No Violations | |
-1872388028 | 2006-12-13 0:00 | DD | No Violations | |
-190019081 | 2007-5-8 0:00:0 | DD | No Violations | |
-1935717682 | 2011-3-3 0:00:0 | PW | No Violations | |
-2040374535 | 2017-12-11 0:00 | UP | No Violations | 0.50 |
-275665592 | 2019-2-14 0:00: | UP | No Violations | 0.50 |
0190019081 | 2007-05-08 | Drill / Deepen / Reopen | No Violations | checking site for restoration area graded |
0205745280 | 2007-05-22 | Production Wells | No Violations | in compliance |
0275665592 | 2019-02-14 | UrbanProduction Wells | Violations Noted | I conducted an inspection on this well. During this inspection, the well was observed to be equipped with a pumping unit and not in production. The valve on the tubing and 2 inch flow line was in the closed position. The well was enclosed with a fence and locked door. The tank battery was comprised of two 100 BBL tanks, one 50 BBL tank and a mechanical separator. Valves on the separator were open. Urban production equipment was installed on the production tanks. The diked tank battery was enclosed by a chain link fence and had a locked door. Legible identification was located at the well and tank battery, however it has not been updated to reflect the new owner information. Lease access to the well and tank battery was stable and secured with a locked gate. I contacted David Oil Company and discussed with office personnel that up-to-date identification needs to be installed at the well and tank battery location. |
0445710855 | 2009-10-20 | Production Wells | No Violations | No violations were found at the time of inspection. |
0885921530 | 2009-09-10 | Production Wells | No Violations | No violations were found. |
1291154166 | 2007-09-25 | Preliminary Restoration | No Violations | area graded and seeded |
1374775953 | 2013-07-25 | UrbanProduction Wells | No Violations | The producing unit consists of a wellhead and pumpjack unit and an aboveground storage tank (AST) battery with two steel 140-barrel production tanks, one poly 50-barrel brine tank, mechanical separator in separate chain-link enclosures. The unit ID is present, and tank spacing and meets requirements. The loadouts are locked. The battery secondary containment is good. No evidence of leaks or problems. There is a locked gate at the lease road which has an ID placard. The leased road is well maintained and the site is in good condition. |
1412267931 | 2014-10-02 | Production Wells | No Violations | I inspected the location of this producing unit as part of routine inspection activity. The well is currently producing. Production reports are current. The well and surrounding area are free from signs of leakage or problems. The tank battery secondary containment is intact. Load-outs are bull-plugged and the gates are locked. No problems noted. |
1501784585 | 2017-08-03 | UrbanProduction Wells | No Violations | I inspected this production well as part of routine inspection activity. The well and associated battery are located on an otherwise undeveloped parcel, in a clearing surrounded by dense woodlands. The access road was in good condition. Fittings and connections at the well and battery were secure. The secondary containment was intact and free from signs of spills or leaks. The load lines were secure. I walked the areas surrounding the well and battery and found no signs of impact or degradation to the natural greenscape. |
1572886578 | 2019-11-4 0:00: | UP | No Violations | |
1580222304 | 2020-1-28 0:00: | UP | No Violations | 0.40 |
1733177752 | 2006-12-20 | Drill / Deepen / Reopen | No Violations | drilling 2700 checking site due to phone calls regrading noise and odors on site with gas meter no readings regrading noise rig has hospital grade mufflers. |
1872388028 | 2006-12-13 | Drill / Deepen / Reopen | No Violations | meeting on site location made checking pit location |
1935717682 | 2011-03-03 | Production Wells | No Violations | There were no violations at the time. |
2040374535 | 2017-12-11 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. The wellhead with pump jack system and associated battery are located on the east side of Auburn road in a clearing on an otherwise undeveloped parcel. At the time of this inspection, I observed the following: Fittings and connections at the wellhead and associated tank battery were secure in separate chain-link enclosures, the access road was in good condition with no drainage problems or wash-outs. The separate enclosure gates were locked and secure. The secondary containment was intact. I walked and inspected the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features. I noted that the well which had recently changed ownership, remained with unit ID from the previous owner. The new owner must update the signage as soon as possible. I notified the owner about the deficiency. |
205745280 | 2007-5-22 0:00: | PW | No Violations | |
445710855 | 2009-10-20 0:00 | PW | No Violations | |
885921530 | 2009-9-10 0:00: | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0275665592 | US-OH-122847 | 2019-02-27 | 9-05E1 | ID (a-i) |
For data sources see[9]