If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21227 | |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Concord Township | |
Operator Name: DAVID OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: ACTIVITIES PRESS | |
License Status: Producing | |
License Date: 2007-01-25 | |
Spud Date: 2007-05-29 | |
Spud Drilling Contractor: ROSS WELL SERVICE | |
Final Drill Date: 2007-06-05 | |
Well Total Depth: 3600.00 ft | |
Configuration: Vertical | |
Latitude: 41.650000 | |
Longitude: -81.230000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-01-25 | Proposed Formations:CLINTON, Issued Date:1/25/2007, Expired Date:1/25/2008 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2007-06-05 | |
Reached Total Depth | 2007-06-05 | |
Completion Report Received | 2007-08-09 | |
Construction Permit Expires | 2008-01-25 | |
Change of Owner | 2016-12-14 | Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2007-11-07 | 3363 | 3396 | 26 |
3363 | 3396 | 26 | |
3363 | 3396 | 26 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 19450 Gal | 100000 | 525M SCF NITROGEN ASSIST |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | JOHN D OIL & GAS COMPANY | 9570.00 | 0.00 | 182 |
2008 | JOHN D OIL & GAS COMPANY | 13386.00 | 91.00 | 365 |
2009 | JOHN D OIL & GAS COMPANY | 10438.00 | 15.00 | 365 |
2010 | JOHN D OIL & GAS COMPANY | 7541.00 | 0.00 | 365 |
2011 | JOHN D OIL & GAS COMPANY | 9997.00 | 0.00 | 365 |
2012 | JOHN D OIL & GAS COMPANY | 10964.00 | 0.00 | 366 |
2013 | JOHN D OIL & GAS COMPANY | 9821.00 | 0.00 | 365 |
2014 | JOHN D OIL & GAS COMPANY | 7944.00 | 0.00 | 365 |
2015 | JOHN D OIL & GAS COMPANY | 3589.00 | 0.00 | 365 |
2016 | DAVID OIL COMPANY LLC | 8.00 | 0.00 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | JOHN D OIL & GAS COMPANY | Brine | 960 | 182 |
2008 | JOHN D OIL & GAS COMPANY | Brine | 480 | 365 |
2009 | JOHN D OIL & GAS COMPANY | Brine | 320 | 365 |
2010 | JOHN D OIL & GAS COMPANY | Brine | 400 | 365 |
2011 | JOHN D OIL & GAS COMPANY | Brine | 240 | 365 |
2012 | JOHN D OIL & GAS COMPANY | Brine | 160 | 366 |
2013 | JOHN D OIL & GAS COMPANY | Brine | 240 | 365 |
2014 | JOHN D OIL & GAS COMPANY | Brine | 50 | 365 |
2015 | JOHN D OIL & GAS COMPANY | Brine | 0 | 365 |
2016 | JOHN D OIL & GAS COMPANY | Brine | 0 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1055072237 | 2020-7-28 0:00: | UP | No Violations | |
-1625598216 | 2011-7-28 0:00: | UP | No Violations | |
-171122176 | 2018-2-13 0:00: | UP | No Violations | 0.50 |
-1851108028 | 2017-12-5 0:00: | UP | No Violations | 0.50 |
-2092054385 | 2011-3-29 0:00: | PL | No Violations | |
-441513356 | 2016-2-9 0:00:0 | UP | No Violations | 0.50 |
-837036967 | 2007-5-30 0:00: | DD | No Violations | |
0045345050 | 2017-04-10 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: the access road to the well and battery, which is comprised of a shared-use asphalt-paved road was in good condition. The separate enclosure gates were locked and secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure and free from leakage. I walked the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features. I did observe the following maintenance deficiency; the load line valves were not secured with locks as required, the ID signage had not been updated to reflect the recent change in ownership. I contacted the well tender (John Magnussen) and advised him about the deficiency. He indicated that the items would be fixed ASAP. |
0092471829 | 2007-05-30 | Drill / Deepen / Reopen | No Violations | drilling |
0171122176 | 2018-02-13 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: missing locks on load-line valves and ID not current and accurate. At the time of this inspection, the noted deficiency remained. In addition, the well signage remains unchanged since the change in ownership that occurred in 2016. Repeated calls to the owner have not produced any demonstrable action or results. |
0441513356 | 2016-02-09 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. The well and associated battery are located in an otherwise open, grassy area on the east side of the commercial building at this location. The well is accessed via a short, unpaved road that connects to the existing asphalt-paved driveway. The battery is immediately adjacent to the asphalt drive. At the time of this inspection, I observed the following: a wellhead with mechanical plunger lift system in a board-on-board enclosure. Fittings and connections at the wellhead were secure. The battery is comprised of two 100-barrel steel production tanks and separator in separate board-on-board enclosures. Enclosure gates were locked and secure. Hatches were closed and sealed. Secondary containment was present and intact. Fittings and connections were secure and free from signs of leakage or problems. I walked the areas surround both the well and battery and did not observe any signs of impact relative to the production activity. Signage was present. I noted the following safety issues: The load-line valves were not locked. |
0558257345 | 2019-01-25 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1851108028, regarding updated identification at the well site location, locks on the load-line valves. At the time of this inspection, the load-lines were not locked as required and the identification has not been updated to reflect current ownership. The door on the fencing surrouding the well was also missing and needs to be replaced and locked.
David Oil Company, LLC needs to: 1) Update and install identification reflecting current owner information 2) Install locks on the load-line valve on the tanks 3) Reinstall the door on the fencing surrounding the well |
0837036967 | 2007-05-30 | Drill / Deepen / Reopen | No Violations | drilling 2800 |
0914648767 | 2009-10-26 | Production Wells | No Violations | There were no violations at the time of inspection. |
1357220154 | 2012-12-05 | UrbanProduction Wells | Violations Noted | The unit is comprised of a two-tank battery (1 140-barrel production and 1 100-barrel brine) and a wellhead with mechanical plunger lift, and mechanical separator, each in separate wood board-on-board enclosures. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . Unit identification is present and legible at the tank battery. The tank battery secondary containment is adequate. I did not observe any leaks, spills, or other signs of contamination. The gates are locked. |
1423841950 | 2015-02-13 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The well is located in a commercial/light industrial area on the north side of Crile Rd. The well is comprised of a wellhead with mechanical plunger lift located 200 feet from the tank battery. The battery, mechanical separator, and battery are in separate board-on-board enclosures. The enclosure for the separator is unlocked and I found the gate to be left open. Load outs at the battery are bull-plugged. Connections and fittings are secure and free from signs of leakage or problems. At the time of this inspection, there are 10 to 15 inches of snowfall, which hinders a thorough inspection of surficial features (e.g. access road, secondary containment interior. I notified Tim Reilly (John D. Oil & Gas) about the need for a lock on the gate. I will follow-up in 30 days. |
1523971565 | 2018-04-17 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: missing locks on load-line valves and ID not current and accurate. At the time of this inspection, the noted deficiency remained. In addition, the well signage remains unchanged since the change in ownership that occurred in 2016. Repeated calls to the owner have not produced any demonstrable action or results. The well was shut-in and no in active production. |
1532301953 | 2007-05-22 | Drill / Deepen / Reopen | No Violations | |
1625598216 | 2011-07-28 | UrbanProduction Wells | Violations Noted | Dike, ID and fencing in compliance. Vent hatches installed and closed. Feedlines are bullplugged. Lightning arrestor and charcoal filter not installed. No locks on gates. |
1761357899 | 2013-10-09 | UrbanProduction Wells | No Violations | The producing unit consists of a wellhead and aboveground storage tank (AST) battery in separate board-on-board enclosures. The wellhead is a mechanical plunger lift unit and is producing. The battery is comprised of 2 100-barrel low-boy steel tanks and separator. Secondary containment, spacing, and signage is good. Process safety equipment (spark arrestor, carbon filter, and low-pressure relief valve) are present. Gates are locked. The hatch lid has been left open by the well tender. The ID placard needs to be moved to the outside of the battery and made visible. Ill contact John D. Oil and let them know about the issues. No other problems otherwise noted. |
1768450386 | 2013-12-03 | UrbanProduction Wells | No Violations | The locks and process safety equipment have been added. No other problems noted. |
1851108028 | 2017-12-05 | UrbanProduction Wells | Violations Noted | I inspected the well location as part of routine inspection activity. The well and associated battery are located behind a commercial building, at the edge of the existing asphalt paved parking and drive area. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery in separate board-on-board enclosures which were locked. Fittings and connections at the well and battery were secure and free from signs of leakage. The secondary containment was intact. I noted the following deficiencies: the load-lines were not locked as required. The ID signage had not been updated to reflect the change of ownership that occurred over 12 month prior to this inspection. The owner must place locks at the load-line valves and place compliant unit identification at the well within 30 days or be subject to additional enforcement. Contact Inspector Stephen Tompkins at 330-907-4647 with questions about this compliance notice. |
2049003611 | 2018-02-13 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and unit identification remained from the prior owner and did not have current, accurate information. At the time of this inspection, I observed the following: the were no locks at the load-line valves. The ID signage remained from ownership and not accurate. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies. |
2092054385 | 2011-03-29 | Preliminary Restoration | No Violations | Preliminary restoration was completed. |
45345050 | 2017-4-10 0:00: | UP | No Violations | |
558257345 | 2019-1-25 0:00: | UP | No Violations | 0.50 |
914648767 | 2009-10-26 0:00 | PW | No Violations | |
92471829 | 2007-5-30 0:00: | DD | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1357220154 | US-OH-110139 | 2015-02-05 | OPERATIONMAINTANCE (a-c) | |
1625598216 | US-OH-115990 | 2011-08-01 | LOCKS | |
1625598216 | US-OH-115991 | 2011-08-01 | General Safety | |
1851108028 | US-OH-118512 | 2017-12-28 | ID (a-i) | |
1851108028 | US-OH-118513 | 2017-12-28 | LOCKS |
For data sources see[9]