Well ID: 34-085-21229 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.64,"lon":-81.2,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Chardon Township | |
Operator Name: DAVID OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: BAILEY | |
License Status: Producing | |
License Date: 2007-03-14 | |
Spud Date: 2007-10-11 | |
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC | |
Final Drill Date: 2007-10-20 | |
Well Total Depth: 3710.00 ft | |
Configuration: Vertical | |
Latitude: 41.640000 | |
Longitude: -81.200000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-03-14 | Proposed Formations:CLINTON, Issued Date:3/14/2007, Expired Date:3/13/2008 6:00:00 AM, Drilling unit acres:32.654, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2007-10-20 | |
Reached Total Depth | 2007-10-20 | |
Completion Report Received | 2007-11-21 | |
Construction Permit Expires | 2008-03-13 | |
Change of Owner | 2016-12-14 | Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-02-21 | 3520 | 3532 | 13 |
2008-02-21 | 3566 | 3617 | 15 |
3520 | 3532 | 13 | |
3566 | 3617 | 15 | |
3520 | 3532 | 13 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 350 Bbl | 58000 | FRAC ALSO INCLUDED 406 MSCF OF N2 | ||
H2O | 0 | 350 Bbl | 40000 | THIS FRAC ALSO INVOLVED 309 MSCF OF N2 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | JOHN D OIL & GAS COMPANY | 8008.00 | 187.00 | 319 |
2009 | JOHN D OIL & GAS COMPANY | 7547.00 | 71.00 | 365 |
2010 | JOHN D OIL & GAS COMPANY | 5113.00 | 41.00 | 365 |
2011 | JOHN D OIL & GAS COMPANY | 4695.00 | 40.00 | 365 |
2012 | JOHN D OIL & GAS COMPANY | 5791.00 | 36.00 | 366 |
2013 | JOHN D OIL & GAS COMPANY | 5445.00 | 36.00 | 365 |
2014 | JOHN D OIL & GAS COMPANY | 4554.00 | 0.00 | 365 |
2015 | JOHN D OIL & GAS COMPANY | 4316.00 | 16.00 | 365 |
2016 | DAVID OIL COMPANY LLC | 829.00 | 0.00 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | JOHN D OIL & GAS COMPANY | Brine | 1120 | 319 |
2009 | JOHN D OIL & GAS COMPANY | Brine | 560 | 365 |
2010 | JOHN D OIL & GAS COMPANY | Brine | 560 | 365 |
2011 | JOHN D OIL & GAS COMPANY | Brine | 400 | 365 |
2012 | JOHN D OIL & GAS COMPANY | Brine | 320 | 366 |
2013 | JOHN D OIL & GAS COMPANY | Brine | 290 | 365 |
2014 | JOHN D OIL & GAS COMPANY | Brine | 200 | 365 |
2015 | JOHN D OIL & GAS COMPANY | Brine | 240 | 365 |
2016 | JOHN D OIL & GAS COMPANY | Brine | 0 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1129005982 | 2012-1-10 0:00: | UL | No Violations | |
-1231004084 | 2007-10-12 0:00 | DD | No Violations | |
-1474791660 | 2015-4-22 0:00: | UP | No Violations | 0.50 |
-1871040661 | 2013-12-4 0:00: | UP | No Violations | |
-2043060893 | 2017-12-5 0:00: | UP | No Violations | 0.50 |
-287613372 | 2016-2-22 0:00: | UP | No Violations | 0.50 |
0133318925 | 2017-09-20 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: The load lines and well enclosure gates were noted to be unlocked and unsecure. At the time of this inspection, the indicated deficiencies remained. In addition, the ID signage remained unchanged and had not been updated to reflect the change in ownership that had occurred in 2016. Repeated calls to the owner have not produced any demonstrable action or results. |
0287613372 | 2016-02-22 | UrbanProduction Wells | Violations Noted | I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with mechanical plunger lift system and tank battery with two 100-barrel, steel production tanks. The well and battery were located in separate board-on-board enclosures. Process safety and air emission control devices (low-pressure relief valve, spark arrestor, and carbon filter) were present. I walked the areas around the wellhead and battery and did not observe any signs of impact relating to the on-going production activity. Access to the well and battery was afforded by a short, dedicated, unpaved access road. Portions of the road were flooded and may indicate active management of surface drainage is warranted. I observed the following deficiencies: the wellhead and battery enclosure, and load-line valves were not secured with locks. The owner must remedy the following by 03/25/2016: secure the load-line valves with locks, secure the enclosures with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
0604271419 | 2007-09-25 | Drill / Deepen / Reopen | No Violations | location made ready for rig |
0975309591 | 2012-11-07 | Production Wells | No Violations | The unit is comprised of a 2-tank battery (1 210-barrel production tank and 1 100-barrel brine tank) and mechanical separator in an 8-foot wooden enclosure. The wellhead includes a mechanical plunger lift located in a 6-foot wooden enclosure. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . Unit identification is present and legible at the tank battery. I did not observe any leaks, spills, or other signs of contamination. No violations noted. |
1129005982 | 2012-01-10 | UrbanPreliminary Restoration | Violations Noted | FOLLOW UP TO NOV # 1327350555 This well is equipped with a plunger lift system. The tank battery is equipped with a heat treat separator and two 100 barrel production tanks. Equipment spacing is correct. The man doors need locks. I contacted Jim from John D and notified him that HB-278 safety equipment needs installed on the well (charcoal filters, vent stacks with low-pressure relief valves, hatch lids with functioning seals and lighting arrestors). |
1231004084 | 2007-10-12 | Drill / Deepen / Reopen | No Violations | surface |
1327350555 | 2012-01-10 | UrbanPreliminary Restoration | Violations Noted | Man doors needs locks. Well is a rabbit well tank has a heat treat separator, two 100BBl production tanks. Spacing is correct. HB-278 safety equipment needs installed on the well, charcoal filter, spark arrestor, low pressure relief valve. Contacted Jim from John D. requested needed equipment be installed to bring well into compliance with HB-278. |
133318925 | 2017-9-20 0:00: | UP | No Violations | |
1474791660 | 2015-04-22 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The wellhead is located at the terminus of an unpaved residential road with sparse, isolated development within a wooded area. The wellhead and battery are located in a clearing in the woods near the road terminus. The well is comprised of a mechanical plunger-lift system in a board-on-board enclosure. Fittings and connections at the wellhead are secure. The battery is comprised of one 100-barrel steel production tank and one 100-barrel brine tank and separator unit in a separate board-on-board enclosure. Fittings are secure. Load-outs are locked. The containment dike is intact and dry. I walked the areas outside of the wellhead and battery including areas down gradient topographically and did not observe any signs of impact or drainage problems associated with the unit. The access road is unpaved by well drained and passable. |
1871040661 | 2013-12-04 | UrbanProduction Wells | Violations Noted | Locks and safety gear in accordance with 1501:9-9-05E has been added. No problems noted. |
1896674482 | 2009-10-20 | Production Wells | No Violations | There were no violations at the time of inspection. |
2043060893 | 2017-12-05 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves and enclosure gates were not locked. At the time of this inspection, I observed the following: there were no locks at the load-line valves and wellhead enclosure gate. In addition, the ID signage has not been updated to reflect the change of ownership that occurred over 12 months prior to this inspection. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance. |
604271419 | 2007-9-25 0:00: | DD | No Violations | |
975309591 | 2012-11-7 0:00: | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0287613372 | US-OH-122985 | 2016-04-27 | LOCKS | |
1129005982 | US-OH-103269 | 2014-01-16 | OPERATIONMAINTANCE (a-c) | |
1327350555 | US-OH-109349 | 2014-06-27 | LOCKS | |
1327350555 | US-OH-109350 | 2014-06-27 | TANKS (a-I) | |
1871040661 | US-OH-118753 | 2014-05-20 | TANKS (a-i) |