34-085-21229

Well Details

Well ID: 34-085-21229
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chardon Township
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: BAILEY
License Status: Producing
License Date: 2007-03-14
Spud Date: 2007-10-11
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2007-10-20
Well Total Depth: 3710.00 ft
Configuration: Vertical
Latitude: 41.640000
Longitude: -81.200000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-03-14 Proposed Formations:CLINTON, Issued Date:3/14/2007, Expired Date:3/13/2008 6:00:00 AM, Drilling unit acres:32.654, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-10-20
Reached Total Depth 2007-10-20
Completion Report Received 2007-11-21
Construction Permit Expires 2008-03-13
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-02-21 3520 3532 13
2008-02-21 3566 3617 15
3520 3532 13
3566 3617 15
3520 3532 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 350 Bbl 58000 FRAC ALSO INCLUDED 406 MSCF OF N2
H2O 0 350 Bbl 40000 THIS FRAC ALSO INVOLVED 309 MSCF OF N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 JOHN D OIL & GAS COMPANY 8008.00 187.00 319
2009 JOHN D OIL & GAS COMPANY 7547.00 71.00 365
2010 JOHN D OIL & GAS COMPANY 5113.00 41.00 365
2011 JOHN D OIL & GAS COMPANY 4695.00 40.00 365
2012 JOHN D OIL & GAS COMPANY 5791.00 36.00 366
2013 JOHN D OIL & GAS COMPANY 5445.00 36.00 365
2014 JOHN D OIL & GAS COMPANY 4554.00 0.00 365
2015 JOHN D OIL & GAS COMPANY 4316.00 16.00 365
2016 DAVID OIL COMPANY LLC 829.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 JOHN D OIL & GAS COMPANY Brine 1120 319
2009 JOHN D OIL & GAS COMPANY Brine 560 365
2010 JOHN D OIL & GAS COMPANY Brine 560 365
2011 JOHN D OIL & GAS COMPANY Brine 400 365
2012 JOHN D OIL & GAS COMPANY Brine 320 366
2013 JOHN D OIL & GAS COMPANY Brine 290 365
2014 JOHN D OIL & GAS COMPANY Brine 200 365
2015 JOHN D OIL & GAS COMPANY Brine 240 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1129005982 2012-1-10 0:00: UL No Violations
-1231004084 2007-10-12 0:00 DD No Violations
-1474791660 2015-4-22 0:00: UP No Violations 0.50
-1871040661 2013-12-4 0:00: UP No Violations
-2043060893 2017-12-5 0:00: UP No Violations 0.50
-287613372 2016-2-22 0:00: UP No Violations 0.50
0133318925 2017-09-20 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: The load lines and well enclosure gates were noted to be unlocked and unsecure. At the time of this inspection, the indicated deficiencies remained. In addition, the ID signage remained unchanged and had not been updated to reflect the change in ownership that had occurred in 2016. Repeated calls to the owner have not produced any demonstrable action or results.
0287613372 2016-02-22 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with mechanical plunger lift system and tank battery with two 100-barrel, steel production tanks. The well and battery were located in separate board-on-board enclosures. Process safety and air emission control devices (low-pressure relief valve, spark arrestor, and carbon filter) were present. I walked the areas around the wellhead and battery and did not observe any signs of impact relating to the on-going production activity. Access to the well and battery was afforded by a short, dedicated, unpaved access road. Portions of the road were flooded and may indicate active management of surface drainage is warranted. I observed the following deficiencies: the wellhead and battery enclosure, and load-line valves were not secured with locks. The owner must remedy the following by 03/25/2016: secure the load-line valves with locks, secure the enclosures with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
0604271419 2007-09-25 Drill / Deepen / Reopen No Violations location made ready for rig
0975309591 2012-11-07 Production Wells No Violations The unit is comprised of a 2-tank battery (1 210-barrel production tank and 1 100-barrel brine tank) and mechanical separator in an 8-foot wooden enclosure. The wellhead includes a mechanical plunger lift located in a 6-foot wooden enclosure. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . Unit identification is present and legible at the tank battery. I did not observe any leaks, spills, or other signs of contamination. No violations noted.
1129005982 2012-01-10 UrbanPreliminary Restoration Violations Noted FOLLOW UP TO NOV # 1327350555 This well is equipped with a plunger lift system. The tank battery is equipped with a heat treat separator and two 100 barrel production tanks. Equipment spacing is correct. The man doors need locks. I contacted Jim from John D and notified him that HB-278 safety equipment needs installed on the well (charcoal filters, vent stacks with low-pressure relief valves, hatch lids with functioning seals and lighting arrestors).
1231004084 2007-10-12 Drill / Deepen / Reopen No Violations surface
1327350555 2012-01-10 UrbanPreliminary Restoration Violations Noted Man doors needs locks. Well is a rabbit well tank has a heat treat separator, two 100BBl production tanks. Spacing is correct. HB-278 safety equipment needs installed on the well, charcoal filter, spark arrestor, low pressure relief valve. Contacted Jim from John D. requested needed equipment be installed to bring well into compliance with HB-278.
133318925 2017-9-20 0:00: UP No Violations
1474791660 2015-04-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead is located at the terminus of an unpaved residential road with sparse, isolated development within a wooded area. The wellhead and battery are located in a clearing in the woods near the road terminus. The well is comprised of a mechanical plunger-lift system in a board-on-board enclosure. Fittings and connections at the wellhead are secure. The battery is comprised of one 100-barrel steel production tank and one 100-barrel brine tank and separator unit in a separate board-on-board enclosure. Fittings are secure. Load-outs are locked. The containment dike is intact and dry. I walked the areas outside of the wellhead and battery including areas down gradient topographically and did not observe any signs of impact or drainage problems associated with the unit. The access road is unpaved by well drained and passable.
1871040661 2013-12-04 UrbanProduction Wells Violations Noted Locks and safety gear in accordance with 1501:9-9-05E has been added. No problems noted.
1896674482 2009-10-20 Production Wells No Violations There were no violations at the time of inspection.
2043060893 2017-12-05 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves and enclosure gates were not locked. At the time of this inspection, I observed the following: there were no locks at the load-line valves and wellhead enclosure gate. In addition, the ID signage has not been updated to reflect the change of ownership that occurred over 12 months prior to this inspection. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance.
604271419 2007-9-25 0:00: DD No Violations
975309591 2012-11-7 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0287613372 US-OH-122985 2016-04-27 LOCKS
1129005982 US-OH-103269 2014-01-16 OPERATIONMAINTANCE (a-c)
1327350555 US-OH-109349 2014-06-27 LOCKS
1327350555 US-OH-109350 2014-06-27 TANKS (a-I)
1871040661 US-OH-118753 2014-05-20 TANKS (a-i)

For data sources see[9]

References