Well Details

Well ID: 34-085-21233
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: OLIVA
License Status: Producing
License Date: 2007-05-15
Spud Date: 2008-01-07
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2008-01-14
Well Total Depth: 3475.00 ft
Configuration: Vertical
Latitude: 41.620000
Longitude: -81.310000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-05-15 Proposed Formations:CLINTON, Issued Date:5/15/2007, Expired Date:5/14/2008 6:00:00 AM, Drilling unit acres:20.233, Proposed Well Type:OG, Proposed Well Class:EOUT
Reached Total Depth 2008-01-14
Completion Report Received 2008-02-29
Construction Permit Expires 2008-05-14
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-06-09 3256 3270 16
3256 3270 16
3256 3270 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 445 Bbl 100000 583 MSCF OF N2 ALSO USED IN FRAC

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 JOHN D OIL & GAS COMPANY 16250.00 120.00 288
2009 JOHN D OIL & GAS COMPANY 12177.00 106.00 365
2010 JOHN D OIL & GAS COMPANY 6537.00 0.00 365
2011 JOHN D OIL & GAS COMPANY 4342.00 44.00 365
2012 JOHN D OIL & GAS COMPANY 3710.00 33.00 366
2013 JOHN D OIL & GAS COMPANY 3257.00 20.00 365
2014 JOHN D OIL & GAS COMPANY 2199.00 0.00 365
2015 JOHN D OIL & GAS COMPANY 4048.00 28.00 365
2016 DAVID OIL COMPANY LLC 1736.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 JOHN D OIL & GAS COMPANY Brine 420 288
2009 JOHN D OIL & GAS COMPANY Brine 160 365
2010 JOHN D OIL & GAS COMPANY Brine 240 365
2011 JOHN D OIL & GAS COMPANY Brine 240 365
2012 JOHN D OIL & GAS COMPANY Brine 160 366
2013 JOHN D OIL & GAS COMPANY Brine 80 365
2014 JOHN D OIL & GAS COMPANY Brine 0 365
2015 JOHN D OIL & GAS COMPANY Brine 156 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1137198768 2009-10-30 0:00 PW No Violations
-243919693 2017-12-12 0:00 UP No Violations
-620581320 2018-4-12 0:00: UP No Violations
0243919693 2017-12-12 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The load-lines were no locked and secure, and the low-pressure relief valve was missing. At the time of this inspection, I observed the following: the noted deficiencies remained. In addition, the unit ID signage had not been updated to reflect the change in ownership that had occurred in 2016. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance.
0298723134 2011-08-08 UrbanProduction Wells Violations Noted Lease road is stable, fencing, dike, spacing and landscaping in compliance. Vent hatches installed. Lightning arrestor and charcoal filter are not installed. Contacted Jim Williams of Great Plains regarding the issues.
0620581320 2018-04-12 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The load-lines were no locked and secure, and the low-pressure relief valve was missing. At the time of this inspection, I observed the following: the noted deficiencies remained. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance.
0750543742 2019-02-07 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1064019358, regarding locks installed on the well fence man door and tank valves on the production tanks, the reinstallation of the pressure relief valve on the production tank. At the time of this inspection, locks still had not been installed on the well fence man door or the tank valves on the production tanks. The pressure relief valve was still located within the diked tank battery but on the ground and not reinstalled on the production tank. Reinstall the pressure relief valve on the production tank, and install locks on the tank valves and well fence man door.
1064019358 2016-02-29 UrbanProduction Wells Violations Noted I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following elements: one wellhead with mechanical plunger-lift system in a board-on-board enclosure, one mechanical separator in a board-on-board enclosure, a tank battery comprised of two 100-barrel steel tanks with associated fittings and tubular connections in separate board-on-board enclosures. I observed the system fittings and connections to be secure and free from leakage. The tank lids were closed and secure. Secondary containment was intact. I walked the areas surrounding the wellhead and battery and did not observe any evidence of impact or erosional deficits. Access to the well is afforded by the shared-use asphalt-paved driveway which enters from Booth Road. At the time of this inspection, the road was in good condition. I observed the following safety deficiency: the wellhead enclosure gate and load-line valve were not locked as required. Spark arrestor, low-pressure relief valve, and carbon filter were present but the low-pressure relief valve had been removed and was laying inside the enclosure. The owner must remedy the following by 03/31/2016: secure the well enclosure gate and load-lines with locks. Replace low-pressure relief valve. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
1137198768 2009-10-30 Production Wells No Violations Preliminary restoration completed. There were no violations at the time of inspection.
1253943101 2011-02-17 Preliminary Restoration No Violations Preliminary restoration was completed and meets requirements.
1593615624 2020-7-1 0:00:0 UP No Violations
1650688623 2013-12-03 UrbanProduction Wells Violations Noted Safety gear in accordance with 1501:9-9-05E has been added. No problems noted.
1819351698 2008-01-16 Drill / Deepen / Reopen No Violations Pits closed and area graded
298723134 2011-8-8 0:00:0 UP No Violations 0.50
750543742 2019-2-7 0:00:0 UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0298723134 US-OH-123106 2011-08-08 General Safety
1064019358 US-OH-101285 2016-04-27 LOCKS
1064019358 US-OH-101286 2016-04-27 TANKS (a-i)
1650688623 US-OH-116278 2015-02-05 OPERATIONMAINTANCE (a-c)

For data sources see[9]