If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21234 | ![]() Sorry, we have no imagery here. Sorry, we have no imagery here. ![]() |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: DAVID OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: LAKELAND | |
License Status: Producing | |
License Date: 2007-05-21 | |
Spud Date: 2007-06-27 | |
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC | |
Final Drill Date: 2007-07-01 | |
Well Total Depth: 3450.00 ft | |
Configuration: Vertical | |
Latitude: 41.640000 | |
Longitude: -81.350000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-05-21 | Proposed Formations:CLINTON, Issued Date:5/21/2007, Expired Date:5/20/2008 6:00:00 AM, Drilling unit acres:20.57, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2007-07-01 | |
Reached Total Depth | 2007-07-01 | |
Completion Report Received | 2007-08-20 | |
Construction Permit Expires | 2008-05-20 | |
Change of Owner | 2016-12-14 | Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2007-11-20 | 3190 | 3205 | 20 |
3190 | 3205 | 20 | |
3190 | 3205 | 20 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 500 Bbl | 100000 | 592M SCF NITROGEN ASSIST |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | JOHN D OIL & GAS COMPANY | 2571.00 | 70.00 | 140 |
2008 | JOHN D OIL & GAS COMPANY | 2419.00 | 314.00 | 365 |
2009 | JOHN D OIL & GAS COMPANY | 1467.00 | 107.00 | 365 |
2010 | JOHN D OIL & GAS COMPANY | 865.00 | 45.00 | 365 |
2011 | JOHN D OIL & GAS COMPANY | 1723.00 | 0.00 | 365 |
2012 | JOHN D OIL & GAS COMPANY | 1333.00 | 0.00 | 366 |
2013 | JOHN D OIL & GAS COMPANY | 429.00 | 55.00 | 365 |
2014 | JOHN D OIL & GAS COMPANY | 226.00 | 0.00 | 365 |
2015 | JOHN D OIL & GAS COMPANY | 215.00 | 0.00 | 365 |
2016 | DAVID OIL COMPANY LLC | 0.00 | 0.00 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | JOHN D OIL & GAS COMPANY | Brine | 640 | 140 |
2008 | JOHN D OIL & GAS COMPANY | Brine | 640 | 365 |
2009 | JOHN D OIL & GAS COMPANY | Brine | 320 | 365 |
2010 | JOHN D OIL & GAS COMPANY | Brine | 80 | 365 |
2011 | JOHN D OIL & GAS COMPANY | Brine | 240 | 365 |
2012 | JOHN D OIL & GAS COMPANY | Brine | 0 | 366 |
2013 | JOHN D OIL & GAS COMPANY | Brine | 160 | 365 |
2014 | JOHN D OIL & GAS COMPANY | Brine | 160 | 365 |
2015 | JOHN D OIL & GAS COMPANY | Brine | 0 | 365 |
2016 | JOHN D OIL & GAS COMPANY | Brine | 0 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1073571618 | 2013-10-9 0:00: | UP | No Violations | |
-1108820360 | 2020-6-2 0:00:0 | UP | No Violations | |
-1537048963 | 2016-2-18 0:00: | UP | No Violations | 0.50 |
-1678595260 | 2018-6-14 0:00: | UP | No Violations | 1.00 |
-535802081 | 2017-12-6 0:00: | UP | No Violations | 0.50 |
0061044947 | 2009-09-17 | Preliminary Restoration | No Violations | Preliminary restoration was completed. |
0119521348 | 2017-04-14 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had noted that the load-line valves were not secure with locks as required. At the time of this inspection, I observed the following: the access road to the well and battery, which is comprised of a dedicated gravel-paved road that enters from Garfield Road and travels 200 feet to the well and battery, was in good condition. The wellhead and battery enclosure gates were locked and secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure and free from leakage. I walked the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features. I did observe the following maintenance and safety deficiencies; the load line valves remain unsecured with locks, the ID signage must be updated to reflect the change in ownership. I attempted to contact both company representatives John Magnussen and Richard Osborne and, as of the filing of this report, no representative of the company has responded. |
0535802081 | 2017-12-06 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves and enclosure gates were not locked. At the time of this inspection, I observed the following: there were no locks at the load-line valves. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance. |
0892745277 | 2007-07-06 | Drill / Deepen / Reopen | No Violations | pits open fenced to be closed Monday |
0897755491 | 2017-09-01 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the load-lines and well enclosure were no secured with locks. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress. |
1030439178 | 2019-5-1 0:00:0 | UP | No Violations | |
1073571618 | 2013-10-09 | UrbanProduction Wells | Violations Noted | The producing unit consists of a wellhead and aboveground storage tank (AST) battery in separate board-on-board enclosures. The wellhead is a mechanical plunger lift unit and is producing. The battery is comprised of 1 140-barrel steel tank and separator. Secondary containment, spacing, and signage is good. Process safety equipment (spar k arrestor, carbon filter, and low-pressure relief valve) are present. Gates are locked. No problems otherwise noted. |
119521348 | 2017-4-14 0:00: | UP | No Violations | 0.50 |
1537048963 | 2016-02-18 | UrbanProduction Wells | Violations Noted | I inspected this producing well as part of routine inspection activity. At the time of my inspection, I observed the following elements: a wellhead with mechanical plunger lift and tank battery consisting of one 100-barrel steel storage tank, with mechanical separator. The battery and wellhead were in in separate board-on-board enclosures. Fittings and connections are free from leakage. The production tank had a spark arrestor, a low-pressure relief valve, and carbon filter as required. The tank lids are closed and sealed. The dedicated access road is in good condition. The enclosure gates were not locked and or secure. The load-line valves were not locked and must be secured with locks. The owner must remedy the following by 03/25/2016: secure the load-line valves and enclosure gates with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
1678595260 | 2018-06-14 | UrbanProduction Wells | No Violations | inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves and enclosure gates were not locked. At the time of this inspection, I observed the following: there were no locks at the load-line valves. The well was not in active production and there was not an active chart record. I noted that there was some gas leaking from the pressure gauge at the 4.5-inch casing . I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance. |
1850180169 | 2011-06-14 | UrbanProduction Wells | Violations Noted | Leae road is stable, gate is locked. Tank battery is fenced and locked. ID sign in place. Dike, spacing in compliance. Vent hatches installed and closed. Lightning arrestor and charcoal filter in place. Feed lines are bullplugged. Wellhead is a rabbit catcher in good repair. Wellhead is not fenced, contacted Jim Williams of Great Plains regarding fencing. |
2130477803 | 2014-02-10 | UrbanProduction Wells | No Violations | The producing unit is comprised of a wellhead with mechanical plunger lift, 1-tank aboveground storage tank battery, and separator unit. The individual elements are in separate board-on-board enclosures which are locked. The unit ID , process safety gear, and secondary containment is present. No problems noted. |
61044947 | 2009-9-17 0:00: | PL | No Violations | |
892745277 | 2007-7-6 0:00:0 | DD | No Violations | |
897755491 | 2017-9-1 0:00:0 | UP | No Violations | 0.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1073571618 | US-OH-101549 | 2015-02-05 | LOCKS | |
1073571618 | US-OH-101550 | 2015-02-05 | TANKS (a-i) | |
1537048963 | US-OH-114822 | 2016-04-27 | LOCKS | |
1850180169 | US-OH-118509 | 2011-08-03 | FENCING (a-d) |
For data sources see[9]