X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-21240

Well Details

Well ID: 34-085-21240
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: LAKELAND
License Status: Producing
License Date: 2007-07-16
Spud Date: 2007-08-02
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2007-08-07
Well Total Depth: 3360.00 ft
Configuration: Vertical
Latitude: 41.640000
Longitude: -81.360000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-07-16 Proposed Formations:CLINTON, Issued Date:7/16/2007, Expired Date:7/15/2008 6:00:00 AM, Drilling unit acres:20.295, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-08-07
Reached Total Depth 2007-08-07
Completion Report Received 2007-09-24
Construction Permit Expires 2008-07-15
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-12-14 3162 3222 21
3162 3222 21
3162 3222 21

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 500 Bbl 100000 568 MSCF OF N2 USED IN FRAC… GM 12/14/07

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 JOHN D OIL & GAS COMPANY 3834.00 171.00 109
2008 JOHN D OIL & GAS COMPANY 5633.00 162.00 365
2009 JOHN D OIL & GAS COMPANY 1673.00 58.00 365
2010 JOHN D OIL & GAS COMPANY 1153.00 72.00 365
2011 JOHN D OIL & GAS COMPANY 1344.00 14.00 365
2012 JOHN D OIL & GAS COMPANY 1304.00 0.00 366
2013 JOHN D OIL & GAS COMPANY 888.00 0.00 365
2014 JOHN D OIL & GAS COMPANY 1086.00 0.00 365
2015 JOHN D OIL & GAS COMPANY 1472.00 0.00 365
2016 DAVID OIL COMPANY LLC 1218.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 JOHN D OIL & GAS COMPANY Brine 520 109
2008 JOHN D OIL & GAS COMPANY Brine 640 365
2009 JOHN D OIL & GAS COMPANY Brine 400 365
2010 JOHN D OIL & GAS COMPANY Brine 160 365
2011 JOHN D OIL & GAS COMPANY Brine 320 365
2012 JOHN D OIL & GAS COMPANY Brine 240 366
2013 JOHN D OIL & GAS COMPANY Brine 340 365
2014 JOHN D OIL & GAS COMPANY Brine 175 365
2015 JOHN D OIL & GAS COMPANY Brine 80 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-110846810 2018-6-14 0:00: UP No Violations 1.00
-11989129 2016-2-18 0:00: UP No Violations 0.50
-1420121754 2020-6-2 0:00:0 UP No Violations
-1559959130 2017-4-14 0:00: UP No Violations 0.50
-2119344183 2017-12-6 0:00: UP No Violations 0.50
0011989129 2016-02-18 UrbanProduction Wells Violations Noted I inspected this producing well as part of routine inspection activity. At the time of my inspection, I observed the following elements: a wellhead with mechanical plunger lift and tank battery consisting of two 100-barrel steel, low-boy storage tanks, with mechanical separator. The battery and wellhead were in in separate board-on-board enclosures. Fittings and connections are free from leakage. The production tank had a spark arrestor, a low-pressure relief valve, and a carbon filter as required. The dedicated access road is in good condition. The enclosure gates were not locked or secure. The load-line valves were not locked and must be secured with locks. The owner must remedy the following by 05/15/2016: secure the load-line valves and enclosure gates with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
0110846810 2018-06-14 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked and secure. At the time of this inspection, I observed the following: there were no locks at the load-line valves and well enclosure gate. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance.
0125518824 2017-12-06 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked and the ID signage was missing. At the time of this inspection, I observed the following: there were no locks at the load-line valves. The ID signage had been updated. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance.
1046499693 2017-09-01 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the load-lines were no secured with locks. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress.
125518824 2017-12-6 0:00: UP No Violations 0.50
132988787 2019-5-16 0:00: UP No Violations
1559959130 2017-04-14 UrbanProduction Wells No Violations I inspected this producing well as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had noted that the load-line valves were not secure with locks as required. In addition, I had noted that the unit ID was missing. At the time of this inspection, I observed the following: the access road to the well and battery, which is comprised of a dedicated gravel-paved road that enters form the existing access road for the Community College and travels 1,800 feet to the well and battery, was in good condition. The battery enclosure gates were locked and secure, however, the wellhead gate was unlocked and open. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure and free from leakage. I walked the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features. I did observe the following maintenance and safety deficiencies; the load line valves remain unsecured with locks. In addition, the ID signage has not been updated to reflect the change in ownership. I attempted to contact both company representatives John Magnussen and Richard Osborne and, as of the filing of this report, no representative of the company has responded.
1605699218 2015-02-06 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well is located within the confines the Lakeland Community College campus. The wellhead and battery are located at the northern-most fringe of the campus and is accessed via a dedicated access road from the main loop drive. My inspection noted the following: The well is comprised of a wellhead mechanical plunger lift and tank battery with 1 100-barrel production tank and 1 100-barrel brine tank with separator unit in separate board-on-board enclosures. At the time of my inspection, the area is covered with up to 14 inches of snow and, as such, elements of the system are obscured with snow cover. Connections and fittings are secure and free from signs of leakage or problems. Load-outs are plugged. Gates to the enclosures are locked. Evaluation of battery interior, lease road condition, and other surficial features is not possible due to snow cover.
1912510951 2011-08-08 UrbanPreliminary Restoration No Violations This site passes Preliminary Restoration.
2119344183 2017-12-06 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked and the ID signage was missing. At the time of this inspection, I observed the following: there were no locks at the load-line valves or well enclosure. The ID signage had been updated. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0011989129 US-OH-105214 2016-04-27 LOCKS

For data sources see[9]

References