34-085-21253

Well Details

Well ID: 34-085-21253
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: WALKER
License Status: Producing
License Date: 2007-11-14
Spud Date: 2008-02-19
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2008-02-27
Well Total Depth: 3120.00 ft
Configuration: Vertical
Latitude: 41.720000
Longitude: -81.260000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-11-14 Proposed Formations:CLINTON, Issued Date:11/14/2007, Expired Date:11/13/2008 6:00:00 AM, Drilling unit acres:21.137, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-02-27
Completion Report Received 2008-04-01
Change of Owner 2008-04-02 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 7447, GREAT PLAINS EXPLORATION LLC
Construction Permit Expires 2008-11-13
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-08-14 2938 2949 20
2938 2949 20
2938 2949 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 578 Mscf 100000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 GREAT PLAINS EXPLORATION LLC 12917.00 0.00 274
2009 GREAT PLAINS EXPLORATION LLC 11702.00 107.00 365
2010 GREAT PLAINS EXPLORATION LLC 8854.00 99.00 365
2011 GREAT PLAINS EXPLORATION LLC 5681.00 34.00 365
2012 GREAT PLAINS EXPLORATION LLC 7726.00 13.00 366
2013 GREAT PLAINS EXPLORATION LLC 7971.00 38.00 365
2014 GREAT PLAINS EXPLORATION LLC 8005.00 27.00 365
2015 GREAT PLAINS EXPLORATION LLC 6224.00 0.00 365
2016 ROCKEFELLER OIL COMPANY LLC 1876.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 GREAT PLAINS EXPLORATION LLC Brine 2000 274
2009 GREAT PLAINS EXPLORATION LLC Brine 740 365
2010 GREAT PLAINS EXPLORATION LLC Brine 720 365
2011 GREAT PLAINS EXPLORATION LLC Brine 320 365
2012 GREAT PLAINS EXPLORATION LLC Brine 320 366
2013 GREAT PLAINS EXPLORATION LLC Brine 240 365
2014 GREAT PLAINS EXPLORATION LLC Brine 330 365
2015 GREAT PLAINS EXPLORATION LLC Brine 320 365
2016 GREAT PLAINS EXPLORATION LLC Brine 76 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1235175970 2014-4-18 0:00: UP No Violations
-1297394392 2010-7-22 0:00: PW No Violations
-1995913358 2009-9-28 0:00: PL No Violations
-2104439966 2008-2-25 0:00: DD No Violations
0224484972 2008-02-27 Drill / Deepen / Reopen No Violations cementing 4.5
0784465910 2008-02-21 Drill / Deepen / Reopen No Violations surface casing cementing
1235175970 2014-04-18 UrbanProduction Wells No Violations I inspected the producing unit in response to a complaint I received from a local resident. The complainant was concerned about some open pits she had observed recently near the tank battery. The findings of my inspection are as follows: The producing unit is comprised of a wellhead with mechanical plunger lift and associated tank battery located in close proximity. The wellhead and battery are in separate chain-link enclosures which are locked. The battery consists of 210-barrel steel production tank and 50 barrel brine tank, with separator in a third, separate chain-link enclosure. Unit spacing meets requirements, and ID placard and secondary containment is present at the battery. I did not observe any signs or indications of leaks, spills, or other problems. There are several large, shallow excavations near the area of the well and battery. The excavations or pits, appear to be related to on-going activities at the property which include handling and storage of mulch and stone. The pits do not appear related to the well production. I advised the complainant that the pits do not appear to be a concern with regards to oil and gas production issues.
1297394392 2010-07-22 Production Wells No Violations There were no violations at the time of inspection.
1456933751 2016-03-02 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. The well and associated battery are located in a secure, gated facility utilized for materials storage. At the time of this inspection, I observed the following elements: a wellhead with mechanical plunger lift system in a chain-link enclosure, a tank battery comprised of one 210-barrel steel tank, one 100-barrel steel tank, a mechanical separator in separate chain-link enclosures. Fittings and connections were bull-plugged but not locked. Low-pressure relief valve, spark arrestor, and carbon filter were not present. At the time of this inspection I observed both storage tanks to be severely corroded and failing in mechanical integrity. The owner must remedy the following by 04/01/2016: remove the failing tanks from service, secure the load-line valves with locks. Place ID signage at the entry gate. Fit the new production tank with spark arrestor, low-pressure relief valve, and carbon filter as required. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
1500385018 2017-07-18 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previous compliance notice. At the time of the previous inspection and issuance of the compliance notice, I had noted the following: Fittings and connections were bull-plugged but not locked. Low-pressure relief valve, spark arrestor, and carbon filter were not present, both storage tanks were severely corroded and failing in mechanical integrity. At the time of this inspection, the indicated issues of non-compliance remain. In addition, the ID signage reflects the previous owner and has not been updated since transfer in 12/16. I contacted John Magnussen with Rockefeller Oil who indicated that the issues will be addressed as they are able.
1524597195 2018-04-24 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previous compliance notice. I had previously noted the following deficiencies: Fittings and connections were bull-plugged but not locked. Low-pressure relief valve, spark arrestor, and carbon filter were not present, both storage tanks were severely corroded and failing in mechanical integrity. At the time of this inspection, the indicated issues of non-compliance remain. In addition, the ID signage reflects the previous owner and has not been updated since transfer in 12/16. John Magnussen has indicated that the company is trying to address the deficiencies.
1580751838 2020-2-3 0:00:0 UP No Violations 0.90
1995913358 2009-09-28 Preliminary Restoration No Violations Preliminary restoration meets the requirements of 1509.072 ORC.
2104439966 2008-02-25 Drill / Deepen / Reopen No Violations drilling 3400 no loss cic or making water.
224484972 2008-2-27 0:00: DD No Violations
784465910 2008-2-21 0:00: DD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1456933751 US-OH-113199 2016-04-27 ID (a-i)
1456933751 US-OH-113200 2016-04-27 LOCKS
1456933751 US-OH-113201 2016-04-27 TANKS (a-i)
1456933751 US-OH-113202 2016-04-27 Well insufficiently equipped to prevent escape of oil and gas

For data sources see[9]