34-085-21267

Well Details

Well ID: 34-085-21267
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Concord Township
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: GRIST MILL
License Status: Producing
License Date: 2008-02-27
Spud Date: 2008-03-31
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2008-04-06
Well Total Depth: 3510.00 ft
Configuration: Vertical
Latitude: 41.660000
Longitude: -81.240000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-02-27 Proposed Formations:CLINTON, Issued Date:2/27/2008, Expired Date:2/26/2009 6:00:00 AM, Drilling unit acres:20.57, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-04-06
Completion Report Received 2008-05-05
Construction Permit Expires 2009-02-26
Change of Owner 2012-01-09 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 7447, GREAT PLAINS EXPLORATION LLC
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-08-28 3337 3390 23
3337 3390 23
3337 3390 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 9202 Gal 21100

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 GREAT PLAINS EXPLORATION LLC 23476.00 0.00 245
2009 GREAT PLAINS EXPLORATION LLC 61170.00 29.00 365
2010 GREAT PLAINS EXPLORATION LLC 21732.00 0.00 365
2011 GREAT PLAINS EXPLORATION LLC 10352.00 0.00 365
2012 GREAT PLAINS EXPLORATION LLC 10780.00 0.00 366
2013 GREAT PLAINS EXPLORATION LLC 11321.00 0.00 365
2014 GREAT PLAINS EXPLORATION LLC 11010.00 0.00 365
2015 GREAT PLAINS EXPLORATION LLC 4768.00 0.00 365
2016 ROCKEFELLER OIL COMPANY LLC 627.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 GREAT PLAINS EXPLORATION LLC Brine 320 245
2009 GREAT PLAINS EXPLORATION LLC Brine 2920 365
2010 GREAT PLAINS EXPLORATION LLC Brine 1520 365
2011 GREAT PLAINS EXPLORATION LLC Brine 1280 365
2012 GREAT PLAINS EXPLORATION LLC Brine 1120 366
2013 GREAT PLAINS EXPLORATION LLC Brine 960 365
2014 GREAT PLAINS EXPLORATION LLC Brine 1000 365
2015 GREAT PLAINS EXPLORATION LLC Brine 319 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1050320681 2009-10-26 0:00 PW No Violations
-1069255594 2016-2-9 0:00:0 UP No Violations 0.50
-118645190 2011-7-28 0:00: UP No Violations
-1242074283 2008-7-23 0:00: PL No Violations
-1468488255 2008-11-5 0:00: PL No Violations
-1801897476 2015-2-13 0:00: UP No Violations 0.50
-1951977191 2008-3-28 0:00: DD No Violations
-1969792143 2013-10-9 0:00: UP No Violations
-665163475 2017-4-6 0:00:0 UP No Violations 0.50
0118645190 2011-07-28 UrbanProduction Wells Violations Noted Dike and ID in compliance. Vent hatches installed and closed. Feedlines are bullplugged. Wellhead gate is not locked. Lightning arrestor and charcoal filter are not installed.
0665163475 2017-04-06 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued Compliance Notice for the following deficiencies: no locks on load-line valves and no gauge on the surface casing annulus as required by permit condition. At the time of this inspection, I found the following: Fittings and connections at the wellhead were secure and free from leakage. The tank battery was comprised of a 100-barrel steel production tank, one 100-barrel steel brine tank, with separator unit located on an otherwise undeveloped parcel in a commercial development. The following conditions remained extant: Load-lines remained unsecure. The surface casing was plumbed to surface but not gauged as required. John Magnusssen with Rockefeller Oil has responded to multiple contacts by saying they are fixing the deficiencies as they are able with their resources at hand.
1050320681 2009-10-26 Production Wells No Violations There were no violations found at the time.
1069255594 2016-02-09 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. The well and associated battery are located in an otherwise open, grassy area within a commercial strip of restaurants. The well and battery are accessed via a short, unpaved road that connects to the existing asphalt-paved driveway of the Waffle House Restaurant. At the time of this inspection, I observed the following: a wellhead with mechanical plunger lift system in a board-on-board enclosure. Fittings and connections at the wellhead were secure. The 8.625-inch casing is valved at surface but not gauged as required by permit condition. The battery is comprised of two 100-barrel steel production tanks and separator in a separate board-on-board enclosure. Enclosure gates were locked and secure. Hatches were closed and sealed. Secondary containment was present and intact. Fittings and connections were secure and free from signs of leakage or problems. I walked the areas surround both the well and battery and did not observe any signs of impact relative to the production activity. Signage was present. I noted the following safety issues: The load-line valves were not locked. The owner must remedy the following by 04/04/2016: secure the load-line valves with locks. Place and maintain a gauge at the surface casing nipple as required by permit condition. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
1095352559 2008-04-01 Drill / Deepen / Reopen No Violations no violation
1242074283 2008-07-23 Preliminary Restoration No Violations
1302288115 2011-04-07 Preliminary Restoration No Violations Preliminary restoration was completed and acceptable.
1415284834 2014-11-06 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead plunger lift and battery are located on a short, dedicated access road from CR 400, beside the Waffle House. Fittings and connections at the wellhead are secure and free from signs of leakage or problems. The battery is comprised of 2 100-barrel steel tank, and a separator. Fittings and connections at the battery are free from signs of leakage or problems. Secondary containment is present. ID signage is present. Load-outs are bull-plugged.
1468488255 2008-11-05 Preliminary Restoration No Violations
1512486566 2017-12-05 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and the 8.625-inch casing was not gauged nor fitted with a pressure relief device as required under the special permit conditions which were part of the drilling permit. At the time of this inspection, I observed the following: the ere no locks at the load-line valves, and the surface casing nipple was not gauged or fitted with a pressure relief device. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and lack of funds, have prevented them from being in compliance.
1518550437 2018-02-13 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and the 8.625-inch casing was not gauged nor fitted with a pressure relief device as required under the special permit conditions which were part of the drilling permit. At the time of this inspection, I observed the following: the were no locks at the load-line valves, and the surface casing nipple was not gauged or fitted with a pressure relief device. The ID signage had been updated to reflect the new ownership. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies.
1548443584 2019-01-25 UrbanProduction Wells No Violations I conducted an compliance notice follow-up inspection for compliance notice 1069255594, the load-line valves not being locked, and the 8.625-inch casing was not gauged nor fitted with a pressure relief device as required under the special permit conditions. At the time of this inspection, no locks were installed on the load-line valves, and the surface casing nipple was not gauged or fitted with a pressure relief device.

Rockefeller Oil Company, LLC still needs to: 1) Install locks on the load-line valves on the tanks 2) The surface casing on the well needs fitted with a pressure relief device and gauged

1668130692 2013-12-02 UrbanProduction Wells Violations Noted Locks and safety gear in accordance with 1501:9-9-05E has been added. No problems noted.
1801897476 2015-02-13 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well is located in a commercial and retail development at the intersection of Auburn Rd. and SR 44. The well is comprised of a wellhead with mechanical plunger lift located 200 feet from the tank battery. The battery, mechanical separator, and battery are in separate board-on-board enclosures. The enclosure for the wellhead is unlocked and I found the gate to be left open with the enclosure partially broken down. Load outs at the battery are bull-plugged. Connections and fittings are secure and free from signs of leakage or problems. At the time of this inspection, there are 10 to 15 inches of snowfall, which hinders a thorough inspection of surficial features (e.g. access road, secondary containment interior. I notified Tim Reilly (John D. Oil & Gas) about the need for a lock on the gate. I will follow-up in 30 days.
1951977191 2008-03-28 Drill / Deepen / Reopen No Violations Site constrution
1969792143 2013-10-09 UrbanProduction Wells No Violations The producing unit consists of a wellhead and aboveground storage tank (AST) battery in separate board-on-board enclosures. The wellhead is a mechanical plunger lift unit and is producing. The battery is comprised of 2 140-barrel steel tanks and separator. Secondary containment, spacing, and signage is good. Process safety equipment (spark arrestor, carbon filter, and low-pressure relief valve) are present. Gates are locked. The ID placard is not visible outside the battery. Ill contact Great Plains and let them know that the placard should be visible outside the battery enclosure. No problems otherwise noted.
744402330 2020-7-28 0:00: UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0118645190 US-OH-104939 2011-08-01 LOCKS
0118645190 US-OH-104940 2011-08-01 General Safety
0118645190 US-OH-104941 2011-08-01 Violation of tank spacing requirements
1069255594 US-OH-101428 2016-04-27 LOCKS
1069255594 US-OH-101429 2016-04-27 General Safety
1668130692 US-OH-116484 2014-05-20 LOCKS
1668130692 US-OH-116485 2014-05-20 TANKS (a-i)

For data sources see[9]