If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21279 | ![]() Sorry, we have no imagery here. Sorry, we have no imagery here. ![]() |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Chardon Township | |
Operator Name: DAVID OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: THIRION | |
License Status: Producing | |
License Date: 2008-05-13 | |
Spud Date: 2008-10-05 | |
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC | |
Final Drill Date: 2008-10-13 | |
Well Total Depth: 3679.00 ft | |
Configuration: Vertical | |
Latitude: 41.640000 | |
Longitude: -81.230000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-05-13 | Proposed Formations:CLINTON, Issued Date:5/13/2008, Expired Date:5/13/2009 6:00:00 AM, Drilling unit acres:20.16, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-10-13 | |
Completion Report Received | 2008-12-10 | |
Construction Permit Expires | 2009-05-13 | |
Change of Owner | 2016-12-14 | Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-01-20 | 3464 | 3475 | 22 |
3464 | 3475 | 22 | |
3464 | 3475 | 22 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 521 Mscf | 100000 | FRAC ALSO INVOLVED 17,529 GAL WATER |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | JOHN D OIL & GAS COMPANY | 262.00 | 0.00 | 35 |
2009 | JOHN D OIL & GAS COMPANY | 3334.00 | 59.00 | 365 |
2010 | JOHN D OIL & GAS COMPANY | 2697.00 | 26.00 | 365 |
2011 | JOHN D OIL & GAS COMPANY | 2353.00 | 0.00 | 365 |
2012 | JOHN D OIL & GAS COMPANY | 1900.00 | 0.00 | 366 |
2013 | JOHN D OIL & GAS COMPANY | 975.00 | 0.00 | 365 |
2014 | JOHN D OIL & GAS COMPANY | 571.00 | 0.00 | 365 |
2015 | JOHN D OIL & GAS COMPANY | 458.00 | 0.00 | 365 |
2016 | DAVID OIL COMPANY LLC | 156.00 | 0.00 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | JOHN D OIL & GAS COMPANY | Brine | 0 | 35 |
2009 | JOHN D OIL & GAS COMPANY | Brine | 320 | 365 |
2010 | JOHN D OIL & GAS COMPANY | Brine | 380 | 365 |
2011 | JOHN D OIL & GAS COMPANY | Brine | 320 | 365 |
2012 | JOHN D OIL & GAS COMPANY | Brine | 80 | 366 |
2013 | JOHN D OIL & GAS COMPANY | Brine | 160 | 365 |
2014 | JOHN D OIL & GAS COMPANY | Brine | 190 | 365 |
2015 | JOHN D OIL & GAS COMPANY | Brine | 80 | 365 |
2016 | JOHN D OIL & GAS COMPANY | Brine | 0 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1438451628 | 2008-10-14 0:00 | DD | No Violations | |
-1448405773 | 2019-6-18 0:00: | UP | No Violations | |
-1452808560 | 2017-9-25 0:00: | UP | No Violations | 0.50 |
-1601432331 | 2017-12-5 0:00: | UP | No Violations | 0.50 |
-64418203 | 2016-2-9 0:00:0 | UP | No Violations | 0.50 |
-938493439 | 2018-2-13 0:00: | UP | No Violations | 0.50 |
0064418203 | 2016-02-09 | UrbanProduction Wells | Violations Noted | I inspected this well as part of routine inspection activity. The well and associated battery are located behind the single-family house at this location. The well and battery are accessed via a short, unpaved road that extends to the east beyond the house driveway for 200 feet. At the time of this inspection, I observed the following: a wellhead with gasoline-fired pump jack system in a board-on-board enclosure. Fittings and connections at the wellhead were secure. The battery is comprised of one 210-barrel steel production tank, one 100-barrel steel brine tank and separator in a separate board-on-board enclosure. Hatches were closed and sealed. Secondary containment was present and intact. Fittings and connections were secure and free from signs of leakage or problems. I walked the areas surround both the well and battery and did not observe any signs of impact relative to the production activity. Signage was present but not visible on the outside of the battery. I noted the following safety issues: The load-line valves were not locked and enclosure gates were unlocked. The owner must remedy the following by 04/08/2016: secure the load-line valves with locks, secure the enclosures with locks. Place proper ID in a conspicuous location on the outside of the battery. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
0163924995 | 2015-04-22 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The well and battery are located in a open, grassy portion on a residential property in an area of mostly sparse residential development. The well is comprised of a mechanical pump-jack system in a board-on-board enclosure which is locked. Fittings and connections at the wellhead are secure. The battery is comprised of one 210-barrel steel production tank and one 100-barrel brine tank and separator unit in a separate board-on-board enclosure. Fittings and connections are secure. The secondary containment is intact and dry. Load-outs are secure. The areas surrounding the well and battery consist mainly of turf grass and woods. I did not observe any signs of impact or drainage problems at the time of this inspection. |
0388314124 | 2017-04-10 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had noted that the load-line valves were not secure with locks as required. At the time of this inspection, I observed the following: the access road to the well and battery, which is comprised of a gravel-paved road that enters from Orchard Road and travels 700 feet to the well and battery, was in good condition with no drainage problems or wash-outs. The separate enclosure gates were locked and secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure and free from leakage. I walked the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features. I did observe the following maintenance and safety deficiencies; the load line valves remain unsecured, the ID signage had not been updated to reflect the recent change in ownership, and the wellhead enclosure has been partially dismantled. |
0938493439 | 2018-02-13 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and unit identification remained from the prior owner and did not have current, accurate information. At the time of this inspection, I observed the following: the were no locks at the load-line valves. The ID signage remained from prior ownership and not accurate. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies. |
1382551236 | 2013-10-23 | UrbanProduction Wells | No Violations | The producing unit consists of a pump jack unit and above-ground storage tank (AST) battery. The battery is comprised of 1 210-barrel steel production tank and 1 100-barrel brine tank, and separator unit. The wellhead and battery are both in separate board-on-board enclosures. The load-outs are bull-plugged. The ID and secondary containment are good. Spark arrestor, carbon filter, and low-pressure relief valve are present. No problems noted. |
1438451628 | 2008-10-14 | Drill / Deepen / Reopen | No Violations | cementing 4.5 |
1452808560 | 2017-09-25 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: missing locks on load-line valves and ID not posted in a visible location. At the time of this inspection, the noted deficiency remained. In addition, the well signage remains unchanged since the change in ownership that occurred in 2016. Repeated calls to the owner have not produced any demonstrable action or results. |
1601432331 | 2017-12-05 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and the ID signage has not been updated to reflect the change of ownership that occurred over 12 months prior to this inspection. At the time of this inspection, I observed the following: there were no locks at the load-line valves, the battery enclosure gate was not locked and left open. In addition, the 8.625-inch casing was not gauged nor fitted with a pressure relief device as required under the special permit conditions which were part of the drilling permit. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance. |
163924995 | 2015-4-22 0:00: | UP | No Violations | 0.50 |
1950863681 | 2009-08-31 | Preliminary Restoration | No Violations | Preliminary restoration meets the requirements of 1509.072 ORC. |
2004017635 | 2018-04-17 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and unit identification remained from the prior owner and did not have current, accurate information. At the time of this inspection, I observed the following: the were no locks at the load-line valves. The ID signage remained from prior ownership and not accurate. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies. |
388314124 | 2017-4-10 0:00: | UP | No Violations | 0.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0064418203 | US-OH-127299 | 2016-04-27 | ID (a-i) | |
0064418203 | US-OH-127300 | 2016-04-27 | LOCKS |
For data sources see[9]