{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.66,"lon":-81.24,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Concord Township | |
Operator Name: ROCKEFELLER OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: LAKE HOSPITAL | |
License Status: Producing | |
License Date: 2009-04-16 | |
Spud Date: 2009-07-19 | |
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC | |
Final Drill Date: 2009-07-26 | |
Well Total Depth: 3499.00 ft | |
Configuration: Vertical | |
Latitude: 41.660000 | |
Longitude: -81.240000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2009-04-16 | Proposed Formations:CLINTON, Issued Date:4/16/2009, Expired Date:4/16/2010 6:00:00 AM, Drilling unit acres:45.37, Proposed Well Type:OG, Proposed Well Class:POOL |
Correction to Well | 2009-05-15 | UNIT SIZE DECREASED TO 20 ACRES. |
Reached Total Depth | 2009-07-26 | |
Completion Report Received | 2009-09-17 | |
Construction Permit Expires | 2010-04-16 | |
Change of Owner | 2016-12-05 | Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-12-21 | 3334 | 3346 | 25 |
3334 | 3346 | 25 | |
3334 | 3346 | 25 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 444 Mscf | 100000 | FRACED WITH 423 BBLS FLUID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | GREAT PLAINS EXPLORATION LLC | 11110.00 | 0.00 | 112 |
2010 | GREAT PLAINS EXPLORATION LLC | 14102.00 | 0.00 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | 5591.00 | 0.00 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | 3855.00 | 0.00 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | 1012.00 | 0.00 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | 743.00 | 0.00 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | 700.00 | 0.00 | 365 |
2016 | ROCKEFELLER OIL COMPANY LLC | 32.00 | 0.00 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | GREAT PLAINS EXPLORATION LLC | Brine | 320 | 112 |
2010 | GREAT PLAINS EXPLORATION LLC | Brine | 400 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | Brine | 240 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 365 |
2016 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0018954744 | 2012-12-05 | UrbanProduction Wells | No Violations | The unit is comprised of a two-tank battery (2 140-barrel) and a wellhead with mechanical plunger lift, and mechanical separator, each in separate enclosures. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . Unit identification is present and legible at the tank battery. The tank battery secondary containment is adequate. I did not observe any leaks, spills, or other signs of contamination. The gates are locked. |
0253486212 | 2009-07-22 | Drill / Deepen / Reopen | No Violations | drilling at 1375 in complance |
0625315264 | 2012-01-12 | UrbanPreliminary Restoration | No Violations | This well is equipped with a plunger lift system and the area around the well hed has been reclaimed. The well head enclosed by a green chain link fence with plastic privacy slats but the fencing is less than 8 feet tall and is next to a parking lot. I Called Jim from John D and requested the well head to be caged. The tank battery has the required HB-278 equipment installed on it and is in good repair. |
0885148654 | 2019-01-25 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1455033320, regarding updated identification at the well site location needing installed and locks added on the tank valve load lines. At the time of this inspection, the identification has not been updated and the load line locks still need to be installed. No other issues were observed at the well or tank battery location, during this inspection. |
1311861967 | 2011-07-28 | UrbanProduction Wells | No Violations | Lease road stable. Dike, spacing, fencing in compliance. ID sign posted. Lightning arrestor, charcoal filter in place. Vent hatches installed and closed. Wellhead is rabbit catcher in good repair. No violations at this time. |
1331729183 | 2012-03-13 | UrbanProduction Wells | No Violations | This well needs working man door locks and the hatches on the production tanks need to be kept closed. I will contact the operator on these issues. |
1381327704 | 2013-10-09 | UrbanProduction Wells | No Violations | The producing unit consists of a wellhead and aboveground storage tank (AST) battery in separate board-on-board enclosures. The wellhead is a mechanical plunger lift. The battery is comprised of 2 140-barrel steels tanks and separator. Secondary containment, spacing, and signage is good. Process safety equipment (spark arrestor, carbon filter, and low-pressure relief valve) are present. The dike drain has been left open. I will contact Great Plains about the open drain. No problems otherwise noted. |
1429709297 | 2015-04-22 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. The well and battery are located in a wooded area on the grounds of the Tripoint Medical Center. The well plunger lift is located in a chain-link enclosure. Connections and fittings are secure. The battery is located in a separate, locked enclosure which is east of the battery. At the time of this inspection the battery is comprised of one 100-barrel steel production tank, one 100-barrel steel brine tank, and separator. The load-outs are plugged and secure. Fittings and connections are secure. Production elements are in good repair. The secondary containment is intact and dry. Areas surrounding the well and battery are free from signs of adverse impact or erosional deficits. There is a small creek which traverses the property from north to south and lies between the battery and wellhead. Flow within the creek is normal and free impact. |
1455033320 | 2016-02-09 | UrbanProduction Wells | Violations Noted | I inspected this well as part of routine inspection activity. The well and associated battery are located in a wooded area on the south side of Tri-Point Med Center. The well is directly accessed from the asphalt-paved parked lot of the hospital. Access to the battery is afforded by a short, unpaved access road from Auburn Road. At the time of this inspection, I observed the following: a wellhead with mechanical plunger lift system in a chain-link enclosure. Fittings and connections at the wellhead were secure. The 8.625-inch casing is gauged and showing 80 psi. The battery is comprised of two 100-barrel steel tanks. Hatches were closed and sealed. Secondary containment was present and intact. Fittings and connections were secure and free from signs of leakage or problems. Signage was present. I walked the areas around both the wellhead and battery and did not observe any signs of impact relating to the production activity. I noted the following safety issues: The enclosure gates at both the well enclosure and battery enclosure were not locked. The load-line valves were not locked. The owner must remedy the following by 04/08/2016: secure the enclosure gates and load-line valves with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
1491828916 | 2017-04-10 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had noted that the load-line valves were not secure with locks as required. At the time of this inspection, I observed the following: the access road to the battery, which is comprised of a gravel-paved road that enters from Auburn Road and travels 60 feet to the battery, was in good condition with no drainage problems or wash-outs. The well is accessed separately via the hospital parking and drive areas and has no dedicated access or lease road. The separate enclosure gates were locked and secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure and free from leakage. I walked the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features.. I did observe the following maintenance and safety deficiencies; the load-line valves remained unsecure and require locks, the ID signage had not been updated to reflect the recent change in ownership. I contacted John Magnussen with Rockefeller Oil and advised him about the continuing defficiencies. He indicated that the items were being worked on as they are able. I contacted Richard Osborne Sr. with David Oil Co., and as of the date of this report, I have not received a response. |
18954744 | 2012-12-5 0:00: | UP | No Violations | |
1924260096 | 2017-12-11 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked and secure. At the time of this inspection, I observed the following: the load line valves were not locked and the ID signage remains unchanged to reflect the new ownership transfer that occurred in 2016. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance. |
253486212 | 2009-7-22 0:00: | DD | No Violations | |
625315264 | 2012-1-12 0:00: | UL | No Violations | |
885148654 | 2019-1-25 0:00: | UP | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1455033320 | US-OH-113164 | 2016-04-27 | LOCKS |
For data sources see[9]