If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21303 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.56,"lon":-81.45,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: OSAIR INC | |
Well Pad ID: | |
Farm/Lease Name: BASS | |
License Status: Producing | |
License Date: 2009-11-04 | |
Spud Date: 2010-02-19 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2010-02-24 | |
Well Total Depth: 3512.00 ft | |
Configuration: Vertical | |
Latitude: 41.560000 | |
Longitude: -81.450000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2009-11-04 | Proposed Formations:CLINTON, Issued Date:11/4/2009, Expired Date:11/4/2010 6:00:00 AM, Drilling unit acres:23.85, Proposed Well Type:OG, Proposed Well Class:EOUT |
Reached Total Depth | 2010-02-24 | |
Completion Report Received | 2010-09-28 | |
Construction Permit Expires | 2010-11-04 | |
Change of Owner | 2012-02-08 | Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 957, OSAIR INC |
Change of Owner | 2013-12-23 | Operator changed from 957, OSAIR INC to 9215, OSAIR INC |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2010-11-26 | 3316 | 3337 | 23 |
3316 | 3337 | 23 | |
3316 | 3337 | 23 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 532 Mscf | 100000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | GREAT PLAINS EXPLORATION LLC | 14691.00 | 1471.00 | 94 |
2011 | OSAIR INC | 36577.00 | 1495.00 | 365 |
2012 | OSAIR INC | 39881.00 | 1013.00 | 366 |
2013 | OSAIR INC | 32292.00 | 619.00 | 365 |
2014 | OSAIR INC | 30900.00 | 411.00 | 365 |
2015 | OSAIR INC | 12210.00 | 24.00 | 365 |
2016 | OSAIR INC | 867.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | GREAT PLAINS EXPLORATION LLC | Brine | 80 | 94 |
2011 | OSAIR INC | Brine | 160 | 365 |
2012 | OSAIR INC | Brine | 320 | 366 |
2013 | OSAIR INC | Brine | 230 | 365 |
2014 | OSAIR INC | Brine | 230 | 365 |
2015 | OSAIR INC | Brine | 0 | 365 |
2016 | OSAIR INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1725230647 | 2012-3-19 0:00: | UP | No Violations | |
-252091491 | 2010-2-20 0:00: | UD | No Violations | |
-431873787 | 2010-9-1 0:00:0 | UD | No Violations | |
-468473357 | 2010-10-19 0:00 | UL | No Violations | |
-694966370 | 2019-12-17 0:00 | UP | No Violations | |
-822422412 | 2016-4-27 0:00: | UP | No Violations | 0.50 |
-868041397 | 2020-8-20 0:00: | UP | No Violations | |
-90786114 | 2020-5-4 0:00:0 | UP | No Violations | |
0026579098 | 2010-02-22 | Urban Drill / Deepen / Reopen | No Violations | Rig was drilling at 2191 feet. All conditions were satisfactory. |
0119959436 | 2010-02-19 | Urban Drill / Deepen / Reopen | No Violations | Conductor was installed and cemented. |
0135225969 | 2016-01-08 | UrbanProduction Wells | No Violations | I inspected this well location pursuant to Complaint #5228 in which the land owner had quesitoned whether the well was being actively produced. At the time of my inspection, the well was in active production. I notified the complainant that the well was in active production. I provided the complainant with the RBDMS record of the annual production and advised him to follow up with the well owner with any questions about production data. |
0252091491 | 2010-02-20 | Urban Drill / Deepen / Reopen | No Violations | The surface casing was installed and cemented. |
0284139307 | 2017-04-17 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The gravel-paved access road to the well was dry and stable. The well and enclosure gates and load-line valves were locked and secure. Fittings and connections at the well were secure and free from leakage. The secondary containment was intact. I walked the areas around the wellhead and battery and found no signs of impact or problems. |
0431873787 | 2010-09-01 | Urban Drill / Deepen / Reopen | No Violations | Contractor was fracing the well. No violations at the time. |
0468473357 | 2010-10-19 | UrbanPreliminary Restoration | No Violations | Fence was up around the well. Warning sign and ID were posted. No violations were found. |
0495977036 | 2010-06-04 | UrbanPreliminary Restoration | No Violations | Bulldozer and track hoe were on site. Topsoil was graded over the well site. Fence was around the well and No Trespassing sign was posted. |
0822422412 | 2016-04-27 | UrbanProduction Wells | Violations Noted | I inspected this well as part of routine inspection activity. The well and battery are located via a dedicated, unpaved access road which enters from White Road. At the time of this inspection, I observed the following: a wellhead with mechanical plunger lift system and tank battery in separate board-on-board enclosures. Enclosure gates were locked and secure. Tank lids were closed and secure. Secondary containment was present and intact. I observed the following safety/maintenance deficiencies: The wellhead enclosure gate lock was broken, and the load-line valves were not secured with locks as required. The ID signage identifies Great Plains Exploration as the current owner which conflicts with current record keeping indicating Osair, Inc. The owner must complete the following by May 27, 2016: Secure the load-line valves and wellhead enclosure gate with locks, update signage to reflect the current owner. Contact Inspector Stephen Tompkins at 330-907-4647 with question regarding this inspection. |
1022095225 | 2010-02-25 | Urban Drill / Deepen / Reopen | No Violations | The production casing was installed and cemented. |
119959436 | 2010-2-19 0:00: | UD | No Violations | |
1270138643 | 2010-02-22 | Urban Drill / Deepen / Reopen | No Violations | No violations were found at the time of inspection. |
135225969 | 2016-1-8 0:00:0 | UP | No Violations | |
1424901013 | 2015-02-25 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. The wellhead and battery are located via a dedicated lease road that runs south from White Road. The wellhead is comprised of a plunger lift system and battery (1 100-barrel lowboy steel production tank and 1 100-barrel lowboy steel brine tank) and mechanical separator in separate board-on-board enclosures. Fittings and connections at the wellhead and battery are secure. Load lines are secure and plugged. Process safety gear is present. 12 to 15 inches of snow cover obscures some surficial features and areas. The area surrounding the well and battery is mostly wooded and meadow with single-family residences beyond. |
1447730866 | 2010-03-04 | Urban Drill / Deepen / Reopen | No Violations | Pits were solidified. |
1477671145 | 2016-10-28 | UrbanProduction Wells | No Violations | I inspected this well location as a follow-up to an previously-issued compliance notice. At the time of the previous inspection, I had observed the following deficiencies: The signage misidentified the well owner. The load-lines were unsecure. At the time of this inspection, the noted deficiencies have been remedied. I noted that the warning signage required by OAC 1501:9-9-05(E)(1) has become faded and unreadable. I contacted John Magnuson with Osair and advised him about the need for proper warning signage. He indicated that he would address it within the next week. I inspected the existing production elements and noted the following: the access road was well drained, the enclosure gates were locked and secure, the load-lines were plugged, locked and secure. The tank lids were closed and sealed. I did not observe any signs of leakage or problems. I walked the areas surrounding the wellhead and tank battery enclosures and did not observe any signs of impact or environmental degradation from the on-going production activity. |
1504619779 | 2017-09-05 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated battery in separate board-on-board enclosures. The enclosure gates were locked. The load-line valves were locked and secure. The secondary containment was intact and free from signs of spills, leaks, or other problems. The gravel-paved access road was in good condition. |
1582224656 | 2020-2-20 0:00: | UP | No Violations | |
1588358302 | 2020-5-1 0:00:0 | UP | No Violations | |
1725230647 | 2012-03-19 | UrbanProduction Wells | No Violations | My inspection of this well site found that this well is equipped with a plunger lift system. The pressure on the annulus was 40 PSI. The well head location is in good repair and the site has been graded, seeded and vegetation is established. Board on board fence has been installed around the tank battery and the wellhead. The mandoor to the wellhead needs a lock and the well owner was notified of this issue. Landscaping has been planted but it has been heavily browsed and damaged by wildlife. The tank battery dike was in good repair and the lease road was stable. |
26579098 | 2010-2-22 0:00: | UD | No Violations | |
284139307 | 2017-4-17 0:00: | UP | No Violations | |
495977036 | 2010-6-4 0:00:0 | UL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0822422412 | US-OH-129378 | 2016-12-21 | ID (a-i) | |
0822422412 | US-OH-129379 | 2016-12-21 | LOCKS |
For data sources see[9]