X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-087-20400

Well Details

Well ID: 34-087-20400
Loading map...
Country: United States
State: Ohio
County: Lawrence
Municipality: Mason Township
Operator Name: PILLAR ENERGY LLC
Well Pad ID:
Farm/Lease Name: HERRELL GEORGE T
License Status: Active Injection
License Date: 1990-10-01
Spud Date: 1986-06-06
Spud Drilling Contractor: GARD DRILLING
Final Drill Date: 1986-06-08
Well Total Depth: 733.00 ft
Configuration: Vertical
Latitude: 38.630000
Longitude: -82.450000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1986-05-07 Issued Date 5/7/86 Expired Date 5/7/87 Acres 0000000 Tool Type RTF Proposed Formation Proposed Depth 00733 Proposed Drill Depth 00733
Original Spud 1986-06-06 CONVERT 10-6-90
Reached Total Depth 1986-06-08 CONVERT 10-6-90
CO 1986-06-24 1089 MITCHELL ENERGY CORP GeoDate 5/7/86
First Injection 1986-06-24 CONVERT 10-6-90
CO 1990-10-01 1089 MITCHELL ENERGY CORP GeoDate 10/1/90
Enhanced Recovery 1990-10-01 Issued Date 10/1/90 Expired Date 10/1/91 Acres 0020190 Tool Type RTF Proposed Formation COW RUN Proposed Depth 00000 Proposed Drill Depth 00000
Annulus Pressure Monitoring Approved 1991-01-15 CONVERT 10-6-90
Completed 1991-05-16 CONVERT 10-6-90
Completion Report Received 1991-06-05 CONVERT 10-6-90
Construction Permit Expires 1991-10-01 CONVERT 10-6-90
Change of Owner 1999-10-22 Operator changed from 1089, MITCHELL ENERGY CORP to 3793, ENERGY SEARCH INC
Last Compliance Report 2000-02-16 CONVERT 10-6-90
Change of Owner 2008-02-26 Operator changed from 3793, ENERGY SEARCH INC to 1388, NORTH COAST ENERGY INC
Change of Owner 2009-12-14 Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC
Change of Owner 2016-02-24 Operator changed from 7578, ENERVEST OPERATING LLC to 9619, PILLAR ENERGY LLC
Record Last Modified 2017-02-15 CONVERT 10-6-90

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-25 699 733 0
699 733 0
699 733 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 213 Bbl 6000 FRAC WITH 213 BBLS OF WATER AND 6000# 20/40 OTTAWA SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1986 MITCHELL ENERGY CORP 0.00 1611.00 183
1987 MITCHELL ENERGY CORP 0.00 2617.00 353
1988 MITCHELL ENERGY CORP 0.00 1810.00 354
1989 MITCHELL ENERGY CORP 0.00 976.00 359
1990 MITCHELL ENERGY CORP 12.00 600.00 365
1991 MITCHELL ENERGY CORP 0.00 10.00 14
1993 MITCHELL ENERGY CORP 0.00 0.00 0
1994 MITCHELL ENERGY CORP 0.00 0.00 365
1995 MITCHELL ENERGY CORP 0.00 0.00 0
1997 MITCHELL ENERGY CORP 0.00 0.00 0
1998 MITCHELL ENERGY CORP 0.00 0.00 0
1999 ENERGY SEARCH INC 0.00 0.00 60
2000 ENERGY SEARCH INC 0.00 0.00 365
2008 EXCO - NORTH COAST ENERGY INC 0.00 0.00 366
2009 EXCO - NORTH COAST ENERGY INC 0.00 0.00 0
2010 ENERVEST OPERATING LLC 0.00 0.00 0
2011 ENERVEST OPERATING LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1986 MITCHELL ENERGY CORP Brine 0 183
1987 MITCHELL ENERGY CORP Brine 28 353
1988 MITCHELL ENERGY CORP Brine 47 354
1989 MITCHELL ENERGY CORP Brine 155 359
1990 MITCHELL ENERGY CORP Brine 245 365
1991 MITCHELL ENERGY CORP Brine 24 14
1993 MITCHELL ENERGY CORP Brine 0 0
1994 MITCHELL ENERGY CORP Brine 0 365
1995 MITCHELL ENERGY CORP Brine 0 0
1997 MITCHELL ENERGY CORP Brine 0 0
1998 MITCHELL ENERGY CORP Brine
1999 MITCHELL ENERGY CORP Brine
2000 ENERGY SEARCH INC Brine 365
2008 EXCO - NORTH COAST ENERGY INC Brine 0 366
2009 EXCO - NORTH COAST ENERGY INC Brine 0 0
2010 ENERVEST OPERATING LLC Brine 0 0
2011 ENERVEST OPERATING LLC Brine 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-100274887 2012-4-5 0:00:0 ER No Violations
-100484016 2004-1-28 0:00: SW No Violations
-1131945288 2014-8-21 0:00: ER No Violations 0.70
-118316517 2019-4-11 0:00: ER No Violations 1.20
-1187236379 2019-4-23 0:00: ER No Violations 0.50
-120892366 2009-11-17 0:00 ER No Violations
-1210192604 2014-11-20 0:00 ER No Violations 0.50
-1413262840 2003-2-6 0:00:0 ER No Violations
-1492906045 2016-11-8 0:00: ER No Violations 0.50
-1499092291 2016-1-22 0:00: ER No Violations 2.00
-1585097339 2015-4-6 0:00:0 ER No Violations 0.50
-1631713347 2010-3-29 0:00: ER No Violations 0.50
-1648843019 2018-11-19 0:00 ER No Violations 1.50
-1751634028 2019-6-12 0:00: ER No Violations 0.50
-1753791838 2013-1-9 0:00:0 ER No Violations 0.50
-1800531080 2004-10-28 0:00 SW No Violations
-182448957 2018-12-10 0:00 ER No Violations 1.00
-1865758770 2013-12-11 0:00 SC No Violations 2.00
-1875742193 2009-8-17 0:00: ER No Violations
-1886734670 2005-2-8 0:00:0 SW No Violations
-192533517 2010-3-19 0:00: ER No Violations
-1948249450 2015-10-5 0:00: ER No Violations 2.00
-1973053198 2009-5-12 0:00: ER No Violations
-2072375462 2019-1-4 0:00:0 ER No Violations 0.70
-2080207704 2013-1-9 0:00:0 ER No Violations 1.50
-244589200 2013-10-21 0:00 ER No Violations 0.70
-266912704 2013-1-7 0:00:0 SC No Violations 2.50
-276170026 2015-2-2 0:00:0 ER No Violations 1.00
-286431364 2019-12-20 0:00 ER No Violations 0.20
-347463342 2006-3-16 0:00: ER No Violations
-360917014 2020-8-11 0:00: ER No Violations 0.50
-42139343 2014-6-20 0:00: ER No Violations 0.50
-423947114 2017-1-18 0:00: ER No Violations 0.50
-526312351 2005-9-14 0:00: ER No Violations
-588170058 2003-11-24 0:00 ER No Violations
-632921682 2018-3-19 0:00: SW No Violations 0.30
-709524368 2019-2-15 0:00: ER No Violations 1.00
-714838616 2020-4-1 0:00:0 ER No Violations 1.00
-790503003 2018-10-22 0:00 ER No Violations 0.70
-823313068 2010-6-4 0:00:0 ER No Violations 1.00
-840986279 2010-3-9 0:00:0 ER No Violations
-922107339 2005-11-10 0:00 ER No Violations
-929906920 2009-2-18 0:00: ER No Violations
001269i463 2001-10-30 Enhanced Recovery Project No Violations No violations.
0014094198 2013-05-02 Enhanced Recovery Project No Violations Inspected the injection pressure, annulus pressure, pump house and containment dike.
0042139343 2014-06-20 Enhanced Recovery Project No Violations Inspected injection pressure, annulus pressure and walked the pipe line right of way. Good identification at the well.
0100274887 2012-04-05 Enhanced Recovery Project No Violations Good Identification.
0100484016 2004-01-28 Salt Water Injection Well No Violations
0118316517 2019-04-11 Enhanced Recovery Project No Violations Compliance Notice # 790503003 follow up inspection. The injection tubing valve is open. The injection line valve at the well site is open. The injection line valve at the pump house is closed.
0120892366 2009-11-17 Enhanced Recovery Project No Violations Good Identification. No violations observed during inspection.
01269i1269 2002-08-06 Enhanced Recovery Project No Violations No violations at this time.
0153465954 2019-03-15 Enhanced Recovery Project No Violations Compliance Notice # 790503003 follow up inspection. The injection line valve at the well site is open. The injection tubing master valve is open. The injection line valve at the pump house is closed. Identification posted. The injection line test has not been scheduled. The contaminated material has not been removed.
0166741216 2010-09-13 Enhanced Recovery Project No Violations Leaking fitting has been fixed. No violations observed during inspection.
0182448957 2018-12-10 Enhanced Recovery Project No Violations Compliance Notice # 790503003 follow up inspection. The injection line valve at the pump house is closed. The injection line valve at the well site is open. The injection tubing master valve is open. Identification is posted at the well site. The containment dike is free of fluids. The injection line test has not been scheduled. The contaminated soil has not been removed from the site.
0192533517 2010-03-19 Enhanced Recovery Project No Violations 2 collar still leaking. I observed that the 2 tubing has been taken apart and pipe joint compound applied to threads. 2 tubing has been threaded into collar so far that only 2 threads are showing. It appears that the threads are not compatible or they are corroded. Either way the leak has not been fixed. I talked to Jim Ross (Enervest Contractor) Jim has turned off the pressure to the well and has agreed to replace the leaking fittings. Jim will leave the tubing exposed until I look at it.
0211833300 2004-08-31 Salt Water Injection Well No Violations Checked annulus pressure after correction of wellhead leak.
0244589200 2013-10-21 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, annulus pressure, and injection pressure. Containment dike is free of water. Good identification at the well head.
0266912704 2013-01-07 Surface Facility Construction No Violations Concrete dike pad has been poured. Concrete block and mortar is on site. Extended concrete apron to unloading pad.
0276170026 2015-02-02 Enhanced Recovery Project No Violations Inspected the injection pressure and annulus pressure. Good identification at well site. The injection 1/4 valve had two hairline cracks that were observed during the inspection on the gauge side. No leaks were observed during the inspection. I talked to Jonathan Ross and told him about the 1/4 valve. Jonathan sent the pumper to close the 2 valve between the injection tubing and the 1/4 valve. The 1/4 valve is to be replaced as soon as possible.
0294527400 2004-06-18 Salt Water Injection Well No Violations High annulus pressure being monitored.
0320102783 2010-06-04 Enhanced Recovery Project No Violations NOV follow up. Repairs have been made to the leaking tubing. Change over adapters that were threaded have now been welded and no leaks were observed while line was pressurized.
0347463342 2006-03-16 Enhanced Recovery Project No Violations Within limits
0376533678 2008-07-23 Enhanced Recovery Project No Violations Good Identification. No violations at this time.
0423947114 2017-01-18 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection pressure, annulus pressure and unloading pad. Identification posted.
0474023838 2006-11-21 Enhanced Recovery Project No Violations Pressure over by 3 psi
0517020568 2013-07-15 Enhanced Recovery Project No Violations Inspected injection pressure, annulus pressure, Containment dike, tanks, pump, and unloading pad. Good identification. A new flow meter has been installed at the well head. Flow meter records in gallons.
0521662370 2016-03-28 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification has not been changed from Enervest to Pillar Energy.
0526312351 2005-09-14 Enhanced Recovery Project No Violations OK.
0588170058 2003-11-24 Enhanced Recovery Project No Violations No violations
0606773329 2008-01-16 Enhanced Recovery Project No Violations Pressure regulators made by Jordan Valves have been installed and are working great. The valves have a max. back pressure of 400psi, and a max. working pressure of 600psi. They are being set slightly below max. injection pressures.
0632921682 2018-03-19 Salt Water Injection Well No Violations I was on location today to check the pressures of this salt water injection well. The annulus pressure was 95 psi, the injection tubing pressure was 120 psi. No violations were noted during my inspection.
0644764013 2008-06-13 Enhanced Recovery Project No Violations No violations at this time.
0654578095 2013-03-15 Enhanced Recovery Project No Violations Inspected injection pressure and annulus pressure. Good identification at wellhead.
0657722604 2004-05-20 Salt Water Injection Well No Violations No problem observed.
0660371969 2012-10-03 Enhanced Recovery Project No Violations Inspected wells with Jon Scott. Measured Injection and Annulus pressure for wells in this field. Well ID was good.
0709524368 2019-02-15 Enhanced Recovery Project No Violations Compliance Notice # 790503003 follow up inspection. Inspected the injection pressure and annulus pressure. The injection line valve at the pump house is shut off. The injection line valve at the well site is open. The injection tubing master valve is open. Identification is posted. The injection line has not been tested. The contaminated soil has not been removed.
0760469911 2010-12-20 Enhanced Recovery Project No Violations Good identification.
0790503003 2018-10-22 Enhanced Recovery Project Violations Noted Inspected the injection pressure and annulus pressure. The injection tubing is on vacuum. While inspecting the surface facility the injection line valve to the well was shut off. Out side the injection facility a scald area 12 feet by 22 feet was observed. A high range Quantab was used in a pool of fluid with in the scald area next to a line marker. The high range Quantab was 8.2 on the strip which is 4621 ppm Cl. The injection line must be repaired or replaced. The injection line must be tested and witnessed by UIC Inspector prior to operation. Submit a plan to the Division of Oil and Gas UIC Section regarding the proposed remediation of the Brine contaminated soil.
0823313068 2010-06-04 Enhanced Recovery Project No Violations Well has been shut down for repairs to line. Well id for Exco-North Coast, Needs to have Enervest information and contact phone numbers. I have talked to Jim Ross (Enervest contractor) about this needing to be changed as soon as possible.
0840986279 2010-03-09 Enhanced Recovery Project No Violations Good identification. Excavated area around brine line, 8 by 8 by 3.5 deep. Have exposed 2 steel line and a steel 90 with a short nipple and a hammer union. There is a brine leak at the 90(steady drip). Another leak with a steady drip is on top of a 2 tee that has a 8 nipple with a collar. Leak is coming from the top of the collar leading to the well. I talked to Jim Ross and he agreed to shut off the pressure to well until repairs could be made. Repair leaks and test line.
0922107339 2005-11-10 Enhanced Recovery Project No Violations Ok.
0929906920 2009-02-18 Enhanced Recovery Project No Violations Good id. No violations observed during inspection.
0933550036 2011-03-17 Enhanced Recovery Project No Violations No violations at this time.
0935821496 2007-04-04 Enhanced Recovery Project No Violations No problems, Jim Ross has grated the lease roads.
0948242039 2004-08-03 Salt Water Injection Well No Violations Wellhead leak resulting in no pressure in annulus; will repair.
0994392076 2014-05-02 Enhanced Recovery Project No Violations Inspected the injection pressure, annulus pressure, Unloading pad, containment dike, tanks, and pump house. Good identification at the well.
1053355788 2003-05-15 Enhanced Recovery Project No Violations No violations at the time of inspection.
1060389843 2008-03-25 Enhanced Recovery Project No Violations No violations were observed. The new pressure regulator is working well.
1073634058 2007-09-25 Enhanced Recovery Project No Violations No violations at this time.
1126964915 2014-07-18 Enhanced Recovery Project No Violations Inspected the annulus pressure, injection pressure, containment dike, tanks, and unloading pad. Good identification at the well.
1131945288 2014-08-21 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, walked the injection line, checked the injection pressure and annulus pressure. Good identification at wellhead.
1145814766 2004-08-30 Salt Water Injection Well No Violations Recheck after replacing packer. Well head leaked initially and the annulus did not hold pressure so this check is a follow-up after that repair.
1155921955 2006-08-15 Enhanced Recovery Project No Violations Within limits
1169770829 2007-01-24 Enhanced Recovery Project No Violations No Problems at this time.
1181134989 2007-05-31 Enhanced Recovery Project No Violations Injection pressure is high 220psi. Jim Ross is correcting the high pressure. No other violations at this time.
1187236379 2019-04-23 Enhanced Recovery Project No Violations Compliance Notice # 790503003 follow up inspection. Inspected the injection pressure, annulus pressure, containment dike, tanks, and unloading pad. Identification posted. Accompanied by UIC Supervisor and UIC Geologist. The injection tubing valve is open, the injection line valve at well site is open, the injection line valve at the pump house is closed. Field tested the line leak site with High Range quantab, results were 6.8 on strip which is 2374 ppm Cl.
1202357396 2006-01-23 Enhanced Recovery Project No Violations Pressures below maximum allowable; pressure on the annulus.
1210192604 2014-11-20 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Good identification at well site.
1252255085 2020-7-14 0:00: ER No Violations 0.50
1258997461 2020-1-22 0:00: ER No Violations 0.50
1269i1269 2002-8-6 0:00:0 ER No Violations
1269i463 2001-10-30 0:00 ER No Violations
1277046721 2016-08-19 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted at the well.
1310699831 2016-06-06 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. The injection pump is currently being rebuilt onsite. The containment dike is free of fluids.
1323871304 2005-04-27 Enhanced Recovery Project No Violations Passed
1365321547 2019-5-28 0:00: ER No Violations 0.10
1392327742 2014-02-13 Enhanced Recovery Project No Violations Bimonthly inspection of ERP field injection wells performed by me and Jon Scott. There are no noticeable leaks in plumbing at wellhead. Identification sign and wellhead in good shape.
14094198 2013-5-2 0:00:0 ER No Violations 1.50
1413262840 2003-02-06 Enhanced Recovery Project Violations Noted Injection pressure measured was 31 psi over maximum. Notified operator.
1435090357 2015-06-23 Salt Water Injection Well No Violations No noted violations.
1447325720 2011-08-02 Enhanced Recovery Project No Violations Good identification. Injection line was shut off due to a line leak at the pump house.
1492906045 2016-11-08 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, unloading pad, injection pumps, injection pressure and annulus pressure. Identification posted at the well. The containment dike is free of fluids.
1499092291 2016-01-22 Enhanced Recovery Project No Violations Inspected the injection pressure and annulus pressure. Identification posted at the well.
1524494361 2019-7-9 0:00:0 ER No Violations 0.50
153465954 2019-3-15 0:00: ER No Violations 1.00
1542206859 2018-11-09 Enhanced Recovery Project No Violations Compliance Notice # 790503003 follow up inspection. The injection line leak location has been recently excavated and the injection line valve in the pump house is open. The injection line valve and the injection tubing master valve are open. The injection line has not been tested by the UIC Inspector. The contaminated soil has not been removed from the site.
1542298304 2018-11-13 Enhanced Recovery Project No Violations Compliance Notice # 790503003 follow up inspection. The injection line valve in the pump house is shut off.
1572285442 2019-10-16 0:00 ER No Violations 1.50
1585097339 2015-04-06 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Walked injection line to well. Identification posted at the well.
1588770808 2020-5-4 0:00:0 ER No Violations 1.50
1596177831 2003-03-27 Enhanced Recovery Project No Violations Injection pressure is below the maximum. Well is in compliance.
1631713347 2010-03-29 Enhanced Recovery Project No Violations Have isolated injection line from well to allow repairs and keep other wells on line. Parts have been ordered. Talked to Jim Ross and he will keep me informed as to when they are done with repairs so I can inspect before they back fill line.
1648843019 2018-11-19 Enhanced Recovery Project No Violations Compliance Notice # 790503003 follow up inspection. The injection line valve in the pump house is closed. The injection line valve at the well head and injection tubing master valve are open. Collected a soil sample from the injection line leak site. ODNR DOGRM Geologist on site.
1652941483 2018-05-24 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pumps, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids.
166741216 2010-9-13 0:00: ER No Violations 0.70
1668737972 2003-10-09 Enhanced Recovery Project No Violations No violations at the time of inspection.
1669452859 2012-10-03 Enhanced Recovery Project No Violations Inspected injection pressure and annulus pressure. Good identification on wellhead.
172602374 2020-3-26 0:00: ER No Violations 0.50
1753791838 2013-01-09 Enhanced Recovery Project No Violations Inspected enhanced recovery well injection tubing pressure and annulus pressure. Good identification at well head. Accompanied by Morgan Button MRI 2.
1800531080 2004-10-28 Salt Water Injection Well No Violations Within limits
1865758770 2013-12-11 Surface Facility Construction No Violations Inspected the changes that have been made to the pump house injection line manifolds and the change over to a different injection pump. Inspected the unloading pad, containment dike and tanks.
1875742193 2009-08-17 Enhanced Recovery Project No Violations Good id. During the inspection an 8 foot by 8 foot area appeared to have been excavated recently . Seed and straw had been applied to the 8 by 8 area and a 10 by 20 area over the hillside. I asked Jim Ross and he told me that they had a leak in the brine line and repaired it.
1886734670 2005-02-08 Salt Water Injection Well No Violations OK
1923926760 2008-09-18 Enhanced Recovery Project No Violations Good id. No violations at this time.
1925468376 2018-07-23 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. The containment dike is free of fluids. Identification posted.
1928386894 2013-09-05 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, annulus pressure, and injection pressure. Containment dike is free of water. Good identification at the wellhead. (flow meter reading is in gallons)
1948249450 2015-10-05 Enhanced Recovery Project No Violations Inspected the injection pressure and annulus pressure. Identification posted at well.
1973053198 2009-05-12 Enhanced Recovery Project No Violations Good id. No violations were observed at time of inspection.
2003694433 2011-12-09 Enhanced Recovery Project No Violations Accompanied Jon Scott for ERP training. Site clean, not exceeding max injection.
2072375462 2019-01-04 Enhanced Recovery Project No Violations Compliance Notice # 790503003 follow up inspection. The injection line valve in the facility pump house is closed. The injection line valve and master valve on the injection tubing are open. Identification is posted. The containment dike is free of fluids. I asked Mike Carr when are they are going to test the injection line. Mike told me he has not been directed to test the injection line. I asked about when the contaminated material is going to be removed and was not given an answer.
2080207704 2013-01-09 Enhanced Recovery Project No Violations Accompanied Jon Scott to this injection well to perform bimonthly inspection and measure its annulus pressure and actual injection pressure.
211833300 2004-8-31 0:00: SW No Violations
2120033476 2010-07-12 Enhanced Recovery Project No Violations Enervest has placed stickers over North Coast Id. 2 steel line is still exposed and needs to be buried.
294527400 2004-6-18 0:00: SW No Violations
320102783 2010-6-4 0:00:0 ER No Violations 0.50
376533678 2008-7-23 0:00: ER No Violations
451040926 2019-11-29 0:00 ER No Violations 0.50
474023838 2006-11-21 0:00 ER No Violations
517020568 2013-7-15 0:00: ER No Violations 0.50
521662370 2016-3-28 0:00: ER No Violations 0.50
606773329 2008-1-16 0:00: ER No Violations
644764013 2008-6-13 0:00: ER No Violations
654578095 2013-3-15 0:00: ER No Violations 0.70
657722604 2004-5-20 0:00: SW No Violations
660371969 2012-10-3 0:00: ER No Violations 0.50
760469911 2010-12-20 0:00 ER No Violations
931447065 2019-9-17 0:00: ER No Violations 0.50
933550036 2011-3-17 0:00: ER No Violations
935821496 2007-4-4 0:00:0 ER No Violations
948242039 2004-8-3 0:00:0 SW No Violations
994392076 2014-5-2 0:00:0 ER No Violations 0.70

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0790503003 US-OH-129002 2018-10-23 9-5-06 Pollution/Contamination
1413262840 US-OH-112153 2003-02-19 Exceeding maximum allowable injection pressure

For data sources see[9]

References