34-089-21993

Well Details

Well ID: 34-089-21993
Loading map...
Country: United States
State: Ohio
County: Licking
Municipality: Fallsbury Township
Operator Name: H & D DRILLING CO INC
Well Pad ID:
Farm/Lease Name: CULLISON SYLVIA J
License Status: Producing
License Date: 1963-02-15
Spud Date: 1963-02-20
Spud Drilling Contractor:
Final Drill Date: 1963-03-25
Well Total Depth: 2974.00 ft
Configuration: Vertical
Latitude: 40.210000
Longitude: -82.250000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1963-02-20
Completed 1963-03-25
Reached Total Depth 1963-03-25
CO 1983-07-21 1524 CANNON EVELYN M
CO 1996-07-11 401 H & D DRILLING CO INC GeoDate
Record Last Modified 2013-10-03

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1100 Bbl 27000

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1992 CANNON EVELYN M 0.00 57.00 365
1993 CANNON EVELYN M 0.00 33.00 156
2006 H & D DRILLING CO INC 0.00 76.00 365
2007 H & D DRILLING CO INC 0.00 37.00 365
2008 H & D DRILLING CO INC 0.00 57.00 365
2009 H & D DRILLING CO INC 0.00 52.00 365
2010 H & D DRILLING CO INC 0.00 76.00 365
2011 H & D DRILLING CO INC 0.00 37.00 365
2012 H & D DRILLING CO INC 0.00 0.00 0
2014 H & D DRILLING CO INC 0.00 0.00 0
2015 H & D DRILLING CO INC 0.00 0.00 0
2016 H & D DRILLING CO INC 0.00 0.00 0
2017 H & D DRILLING CO INC 0.00 157.00 365
2018 H & D DRILLING CO INC 0.00 163.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1992 CANNON EVELYN M Brine 8 365
1993 CANNON EVELYN M Brine 27 156
2006 H & D DRILLING CO INC Brine 10 365
2007 H & D DRILLING CO INC Brine 3 365
2008 H & D DRILLING CO INC Brine 15 365
2009 H & D DRILLING CO INC Brine 15 365
2010 H & D DRILLING CO INC Brine 25 365
2011 H & D DRILLING CO INC Brine 5 365
2012 H & D DRILLING CO INC Brine 0 0
2014 H & D DRILLING CO INC Brine 0 0
2015 H & D DRILLING CO INC Brine 0 0
2016 H & D DRILLING CO INC Brine 0 0
2017 H & D DRILLING CO INC Brine 160 365
2018 H & D DRILLING CO INC Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1412017472 2015-8-11 0:00: PW No Violations
-1707741055 2015-8-24 0:00: PW No Violations
-353755087 2015-7-15 0:00: PW No Violations
0353755087 2015-07-15 Production Wells No Violations Met with well owner Mr. Harold Donaker at tank battery. I instructed Mr. Donaker to pump brine into tanks. Mr. Donaker was also instructed to remediate area below tank battery by tilling and adding lime and topsoil. Mr. Donaker was advised to post proper identification at the tank battery and each wellhead producing into this tank battery. Time of inspection: 3:00 PM.
0830121776 2015-08-31 Production Wells No Violations Inspect tank battery as part of a compliance notice follow-up. Topsoil, seed, and straw have been applied. Identification posted at well and tank battery. Violation has been resolved. Time of inspection: 3:10 PM. Weather: 85*F, Sunny
1412017472 2015-08-11 Production Wells No Violations Inspection conducted as a compliance notice follow-up. Brine has been removed from dike. Area below the dike has not been remediated. Location will continue to be monitored. Time of inspection: 12:10 PM. Weather: 76*F, Sunny
1438084848 2015-07-15 Production Wells Violations Noted Inspect well as part of a compliance notice follow-up for no identification. The well was equipped with a pumping unit and motor. Identification was not posted at the well. The tank battery consists of (2) 100 barrel tanks and a separator inside an earthen dike. Identification was not posted at the tank battery. I observed standing water inside dike. A Quantab test strip for chlorides revealed 5.4 on high range scale which equals >2000 ppm chlorides. Stressed vegetation below dike appears to be caused from brine water being pumped out of dike and/or leaching through the dike wall. Water was observed leaching through dike wall. That water was tested with a Quantab test strip and revealed 7.8 on low range scale which equals >620 ppm for chlorides. A 100 barrel brine tank was located at these coordinates: N 40.21647 W -82.25389. The tank bottom was in poor condition. The well owner will be contacted regarding this inspection. Time of inspection: 10:07 AM. Weather: 75*F, Overcast
1707741055 2015-08-24 Production Wells No Violations Inspect tank battery as follow-up. No change in status. Will continue to monitor. Time of inspection: 10:45 AM. Weather: 68*F, Sunny
1791266007 2015-07-22 Production Wells No Violations Inspect well as part of compliance notive follow-up. Identification has been posted at the well and tank battery. Remediation has not started. Time of inspection: 3:15 PM. Weather: 77*F
1827948903 2020-4-20 0:00: PW No Violations 0.50
830121776 2015-8-31 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1438084848 US-OH-112772 2015-09-16 Well operation causing pollution and contamination
1438084848 US-OH-112773 2015-09-16 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[8]