Well Details

Well ID: 34-089-22766
Loading map...
Country: United States
State: Ohio
County: Licking
Municipality: Bowling Green Township
Operator Name: R H PENICK CO LTD
Well Pad ID:
Farm/Lease Name: CURRIE & CALDWELL
License Status: Final Restoration
License Date: 2016-12-07
Spud Date: 1969-07-26
Spud Drilling Contractor:
Final Drill Date: 1969-09-06
Well Total Depth: 3021.00 ft
Configuration: Vertical
Latitude: 39.940000
Longitude: -82.260000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1969-07-26 GMM UPDATED STATUS TO PA BASED ON PLUG REPORT. UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE.
CO 1969-08-04 755 PENICK R H GeoDate 8/4/69
Completed 1969-09-06 GMM UPDATED STATUS TO PA BASED ON PLUG REPORT. UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE.
Reached Total Depth 1969-09-06 GMM UPDATED STATUS TO PA BASED ON PLUG REPORT. UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE.
APP 2016-12-07 Proposed Formations:CLINTON, Issued Date:12/7/2016, Expired Date:12/7/2018 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2017-05-10 GMM UPDATED STATUS TO PA BASED ON PLUG REPORT. UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE.
Record Last Modified 2017-09-01 GMM UPDATED STATUS TO PA BASED ON PLUG REPORT. UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE.
Construction Permit Expires 2018-12-07 GMM UPDATED STATUS TO PA BASED ON PLUG REPORT. UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE.

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 62832 Gal 26000

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 R H PENICK CO LTD 0.00 170.00 0
1985 R H PENICK CO LTD 0.00 380.00 365
1986 R H PENICK CO LTD 0.00 199.00 365
1987 R H PENICK CO LTD 0.00 297.00 365
1988 R H PENICK CO LTD 0.00 230.00 365
1989 R H PENICK CO LTD 0.00 231.00 365
1990 R H PENICK CO LTD 0.00 165.00 365
1991 J D GAS & OIL INC 0.00 133.00 365
1992 R H PENICK CO LTD 0.00 165.00 365
1993 R H PENICK CO LTD 0.00 134.00 365
1994 R H PENICK CO LTD 0.00 133.00 365
1995 R H PENICK CO LTD 0.00 101.00 365
1996 R H PENICK CO LTD 0.00 98.00 365
1997 R H PENICK CO LTD 0.00 65.00 365
1998 R H PENICK CO LTD 0.00 67.00 365
1999 R H PENICK CO LTD 0.00 69.00 365
2000 R H PENICK CO LTD 0.00 26.00 365
2001 R H PENICK CO LTD 0.00 35.00 365
2002 R H PENICK CO LTD 0.00 39.00 365
2003 R H PENICK CO LTD 0.00 53.00 365
2004 R H PENICK CO LTD 0.00 33.00 365
2005 R H PENICK CO LTD 0.00 29.00 365
2006 R H PENICK CO LTD 0.00 38.00 365
2007 R H PENICK CO LTD 0.00 51.00 365
2008 R H PENICK CO LTD 0.00 126.00 365
2009 R H PENICK CO LTD 0.00 503.00 253
2010 R H PENICK CO LTD 0.00 286.00 365
2011 R H PENICK CO LTD 0.00 229.00 365
2012 R H PENICK CO LTD 0.00 158.00 366
2013 R H PENICK CO LTD 0.00 127.00 365
2014 R H PENICK CO LTD 0.00 130.00 365
2016 R H PENICK CO LTD 0.00 91.00 365
2017 R H PENICK CO LTD 0.00 0.00 0

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 R H PENICK CO LTD Brine 8 0
1985 R H PENICK CO LTD Brine 0 365
1986 R H PENICK CO LTD Brine 0 365
1987 R H PENICK CO LTD Brine 0 365
1988 R H PENICK CO LTD Brine 0 365
1989 R H PENICK CO LTD Brine 0 365
1990 R H PENICK CO LTD Brine 0 365
1991 J D GAS & OIL INC Brine 0 365
1992 R H PENICK CO LTD Brine 0 365
1993 R H PENICK CO LTD Brine 0 365
1994 R H PENICK CO LTD Brine 0 365
1995 R H PENICK CO LTD Brine 0 365
1996 R H PENICK CO LTD Brine 0 365
1997 R H PENICK CO LTD Brine 0 365
1998 R H PENICK CO LTD Brine 0 365
1999 R H PENICK CO LTD Brine 0 365
2000 R H PENICK CO LTD Brine 0 365
2001 R H PENICK CO LTD Brine 0 365
2002 R H PENICK CO LTD Brine 0 365
2003 R H PENICK CO LTD Brine 0 365
2004 R H PENICK CO LTD Brine 0 365
2005 R H PENICK CO LTD Brine 0 365
2006 R H PENICK CO LTD Brine 0 365
2007 R H PENICK CO LTD Brine 0 365
2008 R H PENICK CO LTD Brine 0 365
2009 R H PENICK CO LTD Brine 50 253
2010 R H PENICK CO LTD Brine 20 365
2011 R H PENICK CO LTD Brine 6 365
2012 R H PENICK CO LTD Brine 15 366
2013 R H PENICK CO LTD Brine 0 365
2014 R H PENICK CO LTD Brine 0 365
2016 R H PENICK CO LTD Brine 0 365
2017 R H PENICK CO LTD Brine 0 0

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1273215555 2017-4-21 0:00: PB No Violations
-131821895 2018-10-10 0:00 FR No Violations 0.40
-1986631662 2017-4-20 0:00: PW No Violations
-309815050 2018-10-22 0:00 FR No Violations 0.60
0131821895 2018-10-10 Final Restoration No Violations My inspection revealed that the restoration has not been completed. I observed casing, tubing, rods, and flow line at the well location. The 100 barrel tank has not been removed. I also observed wooden electric poles and electric line. The landowner has recently cut timber on his property. I observed that some trees and limbs have been dropped on the casing and tubing. I contacted Jim Neumeyer at 9:20 AM and discussed the restoration. Mr. Neumeyer said he has Clint Poling scheduled to work on the restoration this coming weekend. Time of inspection: 9:00 AM. Weather: 69 degrees F, Sunny
0309815050 2018-10-22 Final Restoration No Violations My inspection revealed that the restoration has not been completed. During the inspection Clint Poling arrive to look at the location. Clint has agreed to complete the restoration for R.H. Penick. Clint said he will let it dry up some and come back later in the week to do the work. Time of inspection: 8:35 AM. Weather: 36 degrees F, Sunny
0417491913 2018-07-11 Final Restoration Violations Noted My inspection revealed that the final restoration has not been completed. I observed a 100 barrel tank, casing, tubing, rods, and flow line at the well location. The well location and lease road has not been restored. I placed a phone call to Jim Neumeyer at 3:15 PM and advised him that the restoration is past due. The restoration will need to be finished in 15 days in order to be in compliance. Time of inspection: 2:50 PM. Weather: 79 degrees F, Partly cloudy
0890472275 2017-10-27 Final Restoration No Violations This inspection was conducted as a status check. The final restoration has not been completed. A 100 barrel tank as well as tubing/casing was still on location. The well owner is planning to have the landowner waive the flow line/lease road. Time of inspection: 10:35 AM. Weather: 59*F, Sunny
1273215555 2017-04-21 Plug / Plug Back No Violations This inspection was conducted as a status check. During the inspection Phil Moran successfully pulled all of the tubing from the wellbore. The well will now be plugged.
1479484243 2016-11-18 Production Wells No Violations This inspection was conducted as a status check. Ken Wright Well Service was contracted to service well. Ken Wright called to inform me that he has been unable to pull the 2 inch tubing from the well and that the well might be plugged. I met with Ken at the well location to discuss this issue. Ken agreed to try to pump water down the tubing and circulate. Time of inspection: 9:00 AM.
1479749842 2016-11-21 Production Wells No Violations This inspection was conducted as a status check. An attempt was made to pump water down tubing to achieve circulation. The tubing pressured up to 500 pounds and did not circulate. Parafin is causing the tubing to pressure up. Ken Wright will run a parafin knife down the tubing to remove parafin. Mr. Jim Neumeyer stated that the plan is to plug the well. Mr. Neumeyer was advised that the tubing would need to be cleared or removed in order to set a bottom plug. Time of inspection: 8:30 AM.
1541160835 2018-11-02 Final Restoration No Violations No work has been started on the restoration. I will contact Jim Neumeyer and advise him of my inspection. Time of inspection: 8:00 AM. Weather: 45 degrees F, Overcast
1552481854 2019-03-13 Final Restoration No Violations My inspection revealed that the casing, tubing, and 100 barrel tank has been moved down to the field near the tank battery. The well location and lease road will need to be graded and have vegetation established once the weather allows for it. Jim Neumeyer has told me in the past that the landowner would sign a waiver for the lease road and metal flow line. Jim Neumeyer has informed me he is waiting for ground conditions to improve to haul the tank, pipe, and pumping unit from the property. A follow-up will be conducted when the weather conditions improve. Time of inspection: 8:25 AM. Weather: 35 degrees F, Overcast
1557837031 2019-05-14 Final Restoration No Violations My inspection revealed that the casing and tubing has been removed from the property. A 100 barrel tank and pump jack is all that remains. Jim Neumeyer has told me that the landowner will sign a waiver to leave the 2 inch steel flow line and to waive the lease road restoration. Jim told me that the landowner would like to continue to use the lease road. Once the tank and pump jack are removed and a signed waiver received the compliance notice will be resolved. I left a voicemail message for Jim Neumeyer during the inspection. Time of inspection: 8:15 AM. Weather: 46 degrees F, Sunny
1562338547 2019-7-5 0:00:0 FR No Violations 0.20
1565698075 2019-8-13 0:00: FR No Violations 0.10
1568030636 2019-9-9 0:00:0 FR No Violations 0.10
1569930508 2019-10-1 0:00: PW No Violations 0.10
1571146770 2019-10-15 0:00 FR No Violations 0.50
1986631662 2017-04-20 Production Wells No Violations Mr. Jim Neumeyer has contracted Moran Well Service to attempt to remove tubing so that the well can be plugged. The tubing is still locked up in the well. During the inspection Phil Moran attempted to run rods down the tubing. Phil could only get 4 rods in before they would stop.
2036166253 2017-09-21 Final Restoration No Violations The well location was observed as part of a final restoration status check. The inspection revealed casing, tubing, and a 100 barrel tank at the well location. The well location has not been seeded or mulched. The restoration is not due until November. A phone call was placed to Mr. Jim Neumeyer regarding the inspection. Mr. Neumeyer stated he is working on getting the material hauled out and that the landowner is satisfied with the lease road and location as it is. Mr. Neumeyer was advised that a landowner waiver would need to be filled out for the location to remain as is. Time of inspection: 9:30 AM. Weather: 68*F, Sunny
417491913 2018-7-11 0:00: FR No Violations 0.30
890472275 2017-10-27 0:00 FR No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0417491913 US-OH-124449 2018-07-12 NONE3 Failure to complete final restoration within six months

For data sources see[8]

References