If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-089-23160 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.13,"lon":-82.24,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Licking | |
Municipality: Perry Township | |
Operator Name: WILLIAMS PAUL CASEY & AUTUMN J | |
Well Pad ID: | |
Farm/Lease Name: WACHSMAN | |
License Status: Domestic Well | |
License Date: 1977-05-12 | |
Spud Date: | |
Spud Drilling Contractor: | |
Final Drill Date: 1977-08-31 | |
Well Total Depth: 0.00 ft | |
Configuration: Vertical | |
Latitude: 40.130000 | |
Longitude: -82.240000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1977-05-12 | 192 WACHSMAN FRED G & DOROTHY GeoDate 5/12/77 |
Unknown | 1977-05-12 | Issued Date Expired Date Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date |
Completed | 1977-08-31 | RE-ISSUE 12-24-75, R.I. & CH IN OPER 5-18-77 |
Reached Total Depth | 1977-08-31 | RE-ISSUE 12-24-75, R.I. & CH IN OPER 5-18-77 |
CO | 1996-03-20 | 5140 HOOPS LEWIS GeoDate 5/12/77 |
Record Last Modified | 2015-09-24 | RE-ISSUE 12-24-75, R.I. & CH IN OPER 5-18-77 |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1986 | WACHSMAN FRED G & DOROTHY | 0.00 | 263.00 | 0 |
1987 | WACHSMAN FRED G & DOROTHY | 0.00 | 276.00 | 0 |
1988 | WACHSMAN FRED G & DOROTHY | 0.00 | 0.00 | 0 |
1989 | WACHSMAN FRED G & DOROTHY | 0.00 | 0.00 | 90 |
1990 | WACHSMAN FRED G & DOROTHY | 0.00 | 0.00 | 365 |
1995 | HOOPS LEWIS | 0.00 | 204.00 | 247 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1986 | WACHSMAN FRED G & DOROTHY | Brine | 0 | 0 |
1987 | WACHSMAN FRED G & DOROTHY | Brine | 0 | 0 |
1988 | WACHSMAN FRED G & DOROTHY | Brine | 90 | 0 |
1989 | WACHSMAN FRED G & DOROTHY | Brine | 0 | 90 |
1990 | WACHSMAN FRED G & DOROTHY | Brine | 90 | 365 |
1995 | HOOPS LEWIS | Brine | 0 | 247 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1859355497 | 2017-6-22 0:00: | PW | No Violations | 0.20 |
-361569062 | 2012-7-2 0:00:0 | AD | No Violations | |
000PL14039 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
00CENT1098 | 1995-10-05 | Production Wells | No Violations | 1509.07 |
0361569062 | 2012-07-02 | Annular Disposal | Violations Noted | An inspection of this well was conducted, in response to a complaint alleging the disruption of water well. During the inspection, it was noted that the well was equipped and showed signs of production. The tank battery location consisted of (3) 100 bbl tanks. A GPS reading was obtained for the well and tank. While facing East, the well is routed to the the tank on right hand. This tank contained a leak at the heater tube location on bottom of tank consisting of 1 drip per second. Fluid approx 3 in height. High Range Quantabs placed in the fluid showed maximum units of 10 were exceeded. 8.8 units equals 6562 ppm (mg/L)Cl-. The second tank was not connected to the first, but contained an intermittent leak at heater. Old oil was observed near this location. Fluid level approx 1. A line from bottom of this tank transitioned into plastic and was routed back to the well location and found cut with old oil stained ground. The third tank did not appear to be connected at this time. A fourth 100 bbl tank with bottom valve open (tank empty) was observed outside the dike not connected and contained vegetation around area. Brine impacted soils were observed inside the dike contained deer tracks. This soil inside the dike was field tested with High Range Quantabs and showed 8.4 units which equals 5149 ppm (mg/L) Cl-. Identification was not observed at the well or tank(s). The well owner shall repair or replace leaking tanks; Remove all contaminated material from the location. Install identification to show 1.Permit No. 2. Well Name 3. Well No. 4. Owner Name 5. County 6. Emergency Contact No. |
1112147818 | 2020-4-27 0:00: | PW | No Violations | 0.50 |
1206191589 | 2013-05-14 | Production Wells | Violations Noted | This inspection was conducted as a NOV follow-up. The well owner, Mr. Bill Lavender Jr., is not currently registered. The inspection revealed that the well owner has not posted identification at the well head or tank battery. |
1453293830 | 2016-01-15 | Production Wells | No Violations | This inspection was conducted as a compliance notice follow-up. The inspection revealed previous deficiencies have not been resolved. Proper identification has not been posted, the well owner has not registered well with the Division of Oil and Gas Resources Management (DOGRM), and brine-laden soil has not been removed from inside the dike. According to the Licking County tax parcel map the previous landowner/well owner Mr. Bill Lavender Jr. sold the property/well to a Mr. Paul Williams. As a well owner Mr. Williams must be registered with the DOGRM per Ohio Revised Code 1509-07. A Change of Owner Form 7 will need to be filled out and returned to the DOGRM Cental Office. Mr. Williams will have 60 days to bring well into compliance. Failure to comply may result in enforcement action. Time of inspection: 9:30 AM. Weather: 42*F, Overcast |
1522677596 | 2018-04-02 | Production Wells | No Violations | My inspection revealed that the well has not been brought into compliance. Mr. Brent Bear issued a compliance notice on 7/5/2012 for failure to legibly identify well and well operation causing pollution and contamination. The contaminated material has been removed from the tank battery area. I did not observe identification at the well or tank battery. It appears that the old tanks have been replaced with new tanks. The tank battery now consists of (2) 100 barrel tanks inside an earthen dike. The well has not been registered to the current owner. I contacted Mr. Paul Williams by phone on 5/3/18. I advised Mr. Williams that the well needs to be registered. Mr. Williams said he has been working on it but has not been able to contact the previous registered owner. Time of inspection: 9:15 AM. Weather: 34 degrees F, Partly sunny/2 inches snow |
1537282687 | 2018-09-18 | Production Wells | No Violations | My inspection revealed that identification has not been posted at the well. The well has not been registered to the correct owner. Time of inspection: 10:35 AM. Weather: 75 degrees F, Sunny |
1539418017 | 2012-07-02 | Annular Disposal | No Violations | FOLLOW UP TO NOV # -361569062 An inspection of this well was conducted, in response to a complaint alleging the disruption of water well. During the inspection, it was noted that the well was equipped and showed signs of production. The tank battery location consisted of (3) 100 bbl tanks. A GPS reading was obtained for the well and tank. While facing East, the well is routed to the the tank on right hand. This tank contained a leak at the heater tube location on bottom of tank consisting of 1 drip per second. Fluid approx 3 in height. High Range Quantabs placed in the fluid showed maximum units of 10 were exceeded. 8.8 units equals 6562 ppm (mg/L)Cl-. The second tank was not connected to the first, but contained an intermittent leak at heater. Old oil was observed near this location. Fluid level approx 1. A line from bottom of this tank transitioned into plastic and was routed back to the well location and found cut with old oil stained ground. The third tank did not appear to be connected at this time. A fourth 100 bbl tank with bottom valve open (tank empty) was observed outside the dike not connected and contained vegetation around area. Brine impacted soils were observed inside the dike contained deer tracks. This soil inside the dike was field tested with High Range Quantabs and showed 8.4 units which equals 5149 ppm (mg/L) Cl-. Identification was not observed at the well or tank(s). The well owner shall repair or replace leaking tanks; Remove all contaminated material from the location. Install identification to show 1.Permit No. 2. Well Name 3. Well No. 4. Owner Name 5. County 6. Emergency Contact No. |
1713242134 | 2020-2-25 0:00: | EX | No Violations | 0.50 |
1859355497 | 2017-06-22 | Production Wells | No Violations | This inspection was conducted as a follow-up. Identification was not observed at the well or tank battery. The well has not been registered to the current owner. A business card was left at the house. Time of inspection: 1:30 PM. |
2053868481 | 2012-08-08 | Production Wells | No Violations | A follow-up inspection revealed non-compliance. During the inspection, it was noted that the status of previously noted violations remain unchanged. A Compliance Notice was issued with no communication received from well owner. The polish rod located on the pumping unit showed signs of recent pumping. I left a note on my business card referencing that a Compliance Notice was issued and requested a return call. |
CENT1098 | 1995-10-5 0:00: | PW | No Violations | |
PL14039 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0361569062 | US-OH-123812 | 2012-07-02 | Well operation causing pollution and contamination | |
0361569062 | US-OH-123813 | 2012-07-02 | Failure to legibly identify well | |
0361569062 | US-OH-123814 | 2012-07-02 | Equipment pressure rated below operating pressure | |
1206191589 | US-OH-105391 | 2013-06-10 | Failure to register/obtain or maintain bond/insurance |
For data sources see[7]