34-089-23949

Well Details

Well ID: 34-089-23949
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: HOYT-PARRILL & CO
Well Pad ID:
Farm/Lease Name: THE PARRILL CORP
License Status: Producing
License Date: 1982-11-08
Spud Date: 1982-11-17
Spud Drilling Contractor: SHORTS DRLG
Final Drill Date: 1982-11-21
Well Total Depth: 680.00 ft
Configuration: Vertical
Latitude: 40.110000
Longitude: -82.410000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1982-11-08 Issued Date 11/8/82 Expired Date 5/7/83 Acres 0001000 Tool Type CRA Proposed Formation BEREA Proposed Depth 00680 Proposed Drill Depth 00680
Original Spud 1982-11-17 R.I. 11-13-82
Completed 1982-11-21 R.I. 11-13-82
Reached Total Depth 1982-11-21 R.I. 11-13-82
CO 1983-05-01 1270 HOYT-PARRILL & CO GeoDate 11/8/82
Construction Permit Expires 1983-05-07 R.I. 11-13-82
Completion Report Received 1985-02-05 R.I. 11-13-82
Record Last Modified 2017-02-15 R.I. 11-13-82

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 658 670 0
658 670 0
658 670 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 100 Lbs 0 SHOT;100# NITRO

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1400433111 2019-10-8 0:00: PW No Violations
-1503889720 2012-5-11 0:00: AM No Violations
000PL14008 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0721496659 2015-06-11 Production Wells No Violations Inspect well as part of a status check accompanied by Division Intern Brittany Hupp. The well was equipped with a pumping unit but no motor. Identification was not posted at the well. The well did not show signs of recent production. Division Management/Legal will be consulted before further enforcement action is taken. Time of inspection: 3:01 PM. Weather: 85*F, Sunny
0853868333 2017-05-31 Production Wells No Violations This inspection was conducted as a status check. I was accompanied by Orphan Inspector Jeff Fry. An application will be filed and this well will be referred to the Orphan Well Program. Refer to Jeff Frys report for details. Time of inspection: 11:50 AM.
1366720332 2012-01-31 Production Wells No Violations A followup inspection was conducted to verify the status of multiple wells located on this property, which had been referenced within a West Region enforcement case file. During the inspection, it was noted that the well was idle. The well consisted of a pumping unit (Jensen model) with no engine or motor and disconnected bridle, visible 5.5 diameter casing at the surface, rods, and tubing. A tree had grown next to the unit and there were no signs of production. A GPS reading was obtained and recorded for the well. Note: The enforcement case file for wells located on this property date back to the mid-1990s. This case will be discussed with Division Management.
1503889720 2012-05-11 Administrative Inspection No Violations At 11:34 am, I received a call from Mr. Frank Paniccia, the landowner and alleged well owner, stating that his employee Mr. Randy Ayers had scheduled an appointment with an oil guy to reopen the wells. Mr. Paniccia further stated that he told Randy not to mess around and get the locations cleaned up.
721496659 2015-6-11 0:00: PW No Violations
853868333 2017-5-31 0:00: PW No Violations 0.10
PL14008 PL No Violations

For data sources see[5]

References