If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-089-25252 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.95,"lon":-82.41,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Licking | |
Municipality: Licking Township | |
Operator Name: ODOT-PR | |
Well Pad ID: | |
Farm/Lease Name: ODOT-PR | |
License Status: Final Restoration | |
License Date: 2017-06-22 | |
Spud Date: 1986-07-10 | |
Spud Drilling Contractor: | |
Final Drill Date: 1986-08-29 | |
Well Total Depth: 2705.00 ft | |
Configuration: Vertical | |
Latitude: 39.950000 | |
Longitude: -82.410000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1801-01-02 | 2472 ODOT DISTRICT 5/HITCHENS |
Original Spud | 1986-07-10 | ALL OF THE GAS FROM THIS WELL WAS ALWAYS USED FOR THE FACILITY AND IT WAS NOT METERED. NO OIL WAS PRODUCED. AS PER LEWIS ALTIER. 7/3/03 UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE. |
Completed | 1986-08-29 | ALL OF THE GAS FROM THIS WELL WAS ALWAYS USED FOR THE FACILITY AND IT WAS NOT METERED. NO OIL WAS PRODUCED. AS PER LEWIS ALTIER. 7/3/03 UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE. |
Reached Total Depth | 1986-08-29 | ALL OF THE GAS FROM THIS WELL WAS ALWAYS USED FOR THE FACILITY AND IT WAS NOT METERED. NO OIL WAS PRODUCED. AS PER LEWIS ALTIER. 7/3/03 UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE. |
APP | 2017-06-22 | Proposed Formations:CLINTON, Issued Date:6/22/2017, Expired Date:6/22/2019 12:00:00 PM, Drilling unit acres:30, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2017-10-05 | ALL OF THE GAS FROM THIS WELL WAS ALWAYS USED FOR THE FACILITY AND IT WAS NOT METERED. NO OIL WAS PRODUCED. AS PER LEWIS ALTIER. 7/3/03 UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE. |
Record Last Modified | 2018-04-16 | ALL OF THE GAS FROM THIS WELL WAS ALWAYS USED FOR THE FACILITY AND IT WAS NOT METERED. NO OIL WAS PRODUCED. AS PER LEWIS ALTIER. 7/3/03 UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE. |
Construction Permit Expires | 2019-06-22 | ALL OF THE GAS FROM THIS WELL WAS ALWAYS USED FOR THE FACILITY AND IT WAS NOT METERED. NO OIL WAS PRODUCED. AS PER LEWIS ALTIER. 7/3/03 UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 2654 | 2664 | 21 |
2654 | 2664 | 21 | |
2654 | 2664 | 21 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 0 | 0 | SAND |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2016 | ODOT-PR | 0.00 | 0.00 | 0 |
2017 | ODOT-PR | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2016 | ODOT-PR | Brine | 0 | 0 |
2017 | ODOT-PR | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1541157642 | 2017-10-5 0:00: | PB | No Violations | 2.00 |
-1695922455 | 2017-10-4 0:00: | PB | No Violations | 10.00 |
-364019762 | 2017-8-22 0:00: | PW | No Violations | 1.00 |
-621245524 | 2017-9-28 0:00: | PB | No Violations | |
000PL13553 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
001248i287 | 2002-03-06 | Production Wells | Violations Noted | WEATHER CONDITIONS: Sunny and 50 degrees. Inspection revealed No ID posted at the well. |
0171224157 | 2017-09-29 | Plug / Plug Back | No Violations | An inspection of plugging operations revealed Altier Brothers pulling tubing during the inspection. The tubing will be run back into well open ended. The plug job is tentatively set up for 10/4/2017. Time of inspection: 8:30 AM. |
0364019762 | 2017-08-22 | Production Wells | No Violations | A prebid meeting took place at this well location with ODOT Engineer Steve Smith, DOGRM Supervisors Dan Goins and Eric Conrad, and prospective plugging contractors. Time of inspection: 10:00 AM. |
0473581274 | 2014-08-26 | Production Wells | No Violations | This inspection was conducted as a production well status check. The well was equipped with a pumping unit and motor. The tank battery consists of (2) 100 barrel tanks. Identification was not posted at the well or tank battery. A message was left to the ODOT office informing them of inspection. |
0621245524 | 2017-09-28 | Plug / Plug Back | No Violations | An inspection of plugging operations revealed Altier Bros. service rig on the well. The rods were being pulled during the inspection. The plan is to pull tubing and then run back into the well on 9/29/2017 to set the bottom plug. |
1051279682 | 2003-04-25 | Production Wells | Violations Noted | INSPECTION DONE AT THE REQUEST OF MIKE McCORMAC. Inspection revealed the well is capable of production. ID Violation. I meet with Gary Pennington w/ODOT. He advised me that the well is hooked up to their facilities along with Columbia Gas. If the well pressure drops then Columbia Gas would come on line. He advised that Altiers operates the well for them. He was unaware of the Production reporting procedures. I advised Mr. Pennington about the ID violation and advised him on the proper information needed to meet requirements for the ID sign. I called Althier Brothers and spoke with Susan and ask her if they could file the production records from 1986 to 2002. She requested a production form be faxed to her attention and it would be filed. WEATHER CONDITOINS: Cloudy and 54 degrees. |
1079776672 | 2017-11-30 | Plug / Plug Back | No Violations | I witnessed the 10 inch and 8 inch casing cut down to the desired depth per ODOT contract specs. A steel plate labeled with ODNR and permit number 5252 on it was installed on the well. ODOT was responsible to backfill and cover the well with dirt. Time of inspection: 8:30 AM. Weather: 47*F, Overcast |
1248i287 | 2002-3-6 0:00:0 | PW | No Violations | |
1499268741 | 2017-07-05 | Production Wells | No Violations | This inspection was conducted as a status check. I met with ODOT Engineer Steve Smith at the well site. The ODOT has plans to plug the well and recently was issued a plug permit. I discussed proposed plugging procedures for this well with Mr. Smith and the process of hiring contractors. Mr. Smith informed me that once the well is plugged the current ground level elevation of the well will be cut down to the same level as the parking lot area around the well. Time of inspection: 9:00 AM. |
1507044590 | 2017-10-03 | Plug / Plug Back | No Violations | This inspection was conducted as a status check. Altier Brothers was running tubing into the well during the inspection. The well is set to be plugged on 10/4/2017. Time of inspection: 9:00 AM. |
1514295848 | 2017-12-26 | Final Restoration | No Violations | I observed the well location during the inspection. All production equipment has been removed and the location has been restored. The well was backfilled and the location was graded. ODOT is planning on lowering the well location elevation to the same elevation of the gravel parking area and will not be spreading grass seed. The well location meets ORC 1509.072 requirements. Time of inspection: 8:20 AM. Weather: 14*F, Partly cloudy |
1541157642 | 2017-10-05 | Plug / Plug Back | No Violations | This inspection was conducted as a status check. The top of cement was down approximately 60 feet after letting the cement set up overnight. The 8 inch casing was filled solid with Class A neat cement to surface. The cement did not drop. Time of inspection: 9:00 AM. |
1695922455 | 2017-10-04 | Plug / Plug Back | No Violations | I witnessed plugging operations today on the ODOT-PR #1 well. Altier Bros. Inc. was contracted to plug the well with cement. Huffman-Bowers was the cement contractor. I was accompanied by Southwest Region Supervisor Dan Goins and Southwest Region District Supervisor Eric Conrad. ODOT Engineer Steve Smith was present for the plug job. Refer to the plug report for details. Time of inspection: 8:00 AM. |
171224157 | 2017-9-29 0:00: | PB | No Violations | 0.50 |
473581274 | 2014-8-26 0:00: | PW | No Violations | |
PL13553 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
001248i287 | US-OH-106652 | 2002-03-06 | Failure to legibly identify well | |
1051279682 | US-OH-100863 | 2003-04-25 | Failure to legibly identify well |
For data sources see[9]