If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-089-26105 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.11,"lon":-82.53,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Licking | |
Municipality: Granville Township | |
Operator Name: DAVID R HILL INC | |
Well Pad ID: | |
Farm/Lease Name: LUNAU-SCHMID | |
License Status: Producing | |
License Date: 2012-06-05 | |
Spud Date: 2012-07-09 | |
Spud Drilling Contractor: KILBARGER DRLG | |
Final Drill Date: 2012-07-21 | |
Well Total Depth: 4365.00 ft | |
Configuration: Vertical | |
Latitude: 40.110000 | |
Longitude: -82.530000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-06-05 | Proposed Formations:TRENTON THRU TREMPELEAU, Issued Date:6/5/2012, Expired Date:6/5/2014 12:00:00 PM, Drilling unit acres:110, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2012-07-21 | |
Completion Report Received | 2012-10-10 | |
Construction Permit Expires | 2014-06-05 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2012-10-11 | 4228 | 4233 | 11 |
2012-10-11 | 4239 | 4245 | 13 |
2012-10-11 | 4249 | 4252 | 7 |
2012-10-11 | 4254 | 4256 | 5 |
2012-10-11 | 4221 | 4226 | 11 |
4184 | 4186 | 5 | |
4190 | 4192 | 5 | |
4205 | 4212 | 15 | |
4215 | 4218 | 7 | |
4221 | 4226 | 11 | |
4228 | 4233 | 11 | |
4239 | 4245 | 13 | |
4246 | 4248 | 5 | |
4249 | 4252 | 7 | |
4254 | 4256 | 5 | |
4257 | 4259 | 5 | |
4260 | 4262 | 5 | |
4184 | 4186 | 5 | |
2012-10-11 | 4215 | 4218 | 7 |
2012-10-11 | 4184 | 4186 | 5 |
2012-10-11 | 4190 | 4192 | 5 |
2012-10-11 | 4205 | 4212 | 15 |
2012-10-11 | 4257 | 4259 | 5 |
2012-10-11 | 4260 | 4262 | 5 |
2012-10-11 | 4246 | 4248 | 5 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2012-08-03 | ACID | 15 | 5178 Gal | 0 | Producers Service Corporation |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | DAVID R HILL INC | 2886.00 | 0.00 | 103 |
2013 | DAVID R HILL INC | 103439.00 | 0.00 | 365 |
2014 | DAVID R HILL INC | 33722.00 | 0.00 | 365 |
2015 | DAVID R HILL INC | 15076.00 | 0.00 | 365 |
2016 | DAVID R HILL INC | 8678.00 | 0.00 | 365 |
2017 | DAVID R HILL INC | 3445.00 | 0.00 | 365 |
2018 | DAVID R HILL INC | 1876.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | DAVID R HILL INC | Brine | 0 | 103 |
2013 | DAVID R HILL INC | Brine | 0 | 365 |
2014 | DAVID R HILL INC | Brine | 0 | 365 |
2015 | DAVID R HILL INC | Brine | 0 | 365 |
2016 | DAVID R HILL INC | Brine | 0 | 365 |
2017 | DAVID R HILL INC | Brine | 0 | 365 |
2018 | DAVID R HILL INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1974383177 | 2012-7-12 0:00: | DD | No Violations | |
-2073906631 | 2012-7-19 0:00: | DD | No Violations | |
1342135374 | 2012-07-11 | Drill / Deepen / Reopen | No Violations | An inspection of drilling operations revealed that the DV survey showed the surface hole was off 7 degrees from approx 550 to 715. Appalachian Well Service enroute to verify this survey. |
1358177978 | 2012-12-04 | Production Wells | No Violations | I inspected this well and tank battery today in regards to a landowner complaint the Division received about a petroleum odor coming from the tank battery. This landowner lives across the street from the tank battery. This well does not require a pumping unit. Identification was posted at the well head and at the tank battery. Valves were in the open position at the well head. The tank battery consist of (2) 210 barrel tanks and a plastic 1600 gallon brine tank inside of an earthened dike. A second dike consist of a horizontal heater treater. The two storage tanks each have charcoal filters on the top of each tank. The distance between the tank battery and the road is approximately 200 feet. I walked down to the road with a gas detector. It did not pick up any methane nor did I smell a petroleum odor at the time of the inspection. |
1389792961 | 2013-12-30 | Preliminary Restoration | No Violations | This inspection was conducted as a preliminary restoration status check. The well is equipped with a rabbit wellhead. The wellhead is fenced in. Identification was posted at the wellhead. The area around the well has been restored. The tank battery consists of (2) 210 barrel tanks and (1) 2100 gallon plastic tank inside an earthen dike. The tanks were equipped with charcoal filters. The tank battery also consists of a heater treater in a separate dike. Identification was posted at the tank battery. A GPS reading was taken at the access road entry. Inspection meets ORC 1509.072 requirements. |
1974383177 | 2012-07-12 | Drill / Deepen / Reopen | No Violations | I witnessed the cementing of the surface casing. Good cement returns were observed and stayed at the surface. Note: Applachian Well Service had verified that wellbore was off 7 degrees (not witnessed). |
1994199852 | 2012-07-12 | Drill / Deepen / Reopen | No Violations | I witnessed the BOP test today. The BOP passed the required test. |
2073906631 | 2012-07-19 | Drill / Deepen / Reopen | No Violations | An inspection revealed rotary rig drilling a 7.88 hole on air/soap. The depth at time of inspection was 3935. No violations were noted. |
For data sources see[9]