If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-089-26174 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40,"lon":-82.41,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Licking | |
Municipality: Licking Township | |
Operator Name: ARTEX OIL COMPANY | |
Well Pad ID: | |
Farm/Lease Name: MCKAY UNIT | |
License Status: Producing | |
License Date: 2015-11-05 | |
Spud Date: 2015-11-16 | |
Spud Drilling Contractor: KILBARGER DRLG | |
Final Drill Date: 2015-12-03 | |
Well Total Depth: 4629.00 ft | |
Configuration: Vertical | |
Latitude: 40.000000 | |
Longitude: -82.410000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2015-11-05 | Proposed Formations:KNOX, Issued Date:11/5/2015, Expired Date:11/4/2017 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EDPW |
Reached Total Depth | 2015-12-03 | |
Completion Report Received | 2016-02-26 | |
Record Last Modified | 2017-10-23 | |
Construction Permit Expires | 2017-11-04 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2016-09-09 | 4452 | 4517 | 89 |
4452 | 4517 | 89 | |
4452 | 4517 | 89 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2015-12-09 | ACID | 15 | 5000 Gal | 0 | Producers Service Corporation |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2016 | ARTEX OIL COMPANY | 8948.00 | 790.00 | 365 |
2017 | ARTEX OIL COMPANY | 1432.00 | 509.00 | 365 |
2018 | ARTEX OIL COMPANY | 533.00 | 277.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2016 | ARTEX OIL COMPANY | Brine | 809 | 365 |
2017 | ARTEX OIL COMPANY | Brine | 122 | 365 |
2018 | ARTEX OIL COMPANY | Brine | 100 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1205274678 | 2015-11-19 0:00 | DD | No Violations | |
-126147139 | 2016-6-8 0:00:0 | PL | No Violations | |
-1296966045 | 2016-4-21 0:00: | PW | No Violations | |
-1436017470 | 2016-4-20 0:00: | PW | No Violations | |
-1578915167 | 2016-5-20 0:00: | PL | No Violations | |
-1848997112 | 2015-11-20 0:00 | CS | No Violations | |
-1865737304 | 2020-8-3 0:00:0 | PW | No Violations | 0.50 |
0126147139 | 2016-06-08 | Preliminary Restoration | No Violations | This inspection was conducted as a preliminary restoration status check. The access road has been reclaimed and crops have been planted. The new lease road can be accessed from Kirby Rd. off of State Route 13. Inspection meets ORC 1509.072 requirements. Identification was observed at the tank battery. No violations. Time of inspection: 11:20 AM. Weather: 61*F, Cloudy |
1125621259 | 2016-04-19 | Production Wells | Violations Noted | Inspect well location as a status check. The well was equipped with a plunger lift system. A chart was observed at the wellhead. The area around the well has not been reclaimed yet. The preliminary restoration is due 6/3/2016. My inspection revealed that the air pit has not been closed. It was observed that pit water has breached pit wall. A water hole approximately 10 feet x 10 feet was observed just outside the pit. A low range Quantab titrator for Chlorides was used to field test water outside of the pit in two different places on opposite sides of the water hole. The test resulted in a 7.0 on the Quantab scale which equals approximately 447 ppm for chlorides on one side of the water hole and a 2.6 which equals approximately 69 ppm for chlorides on the other side of the water hole. The water in the pit was field tested as well. The pit water resulted in a 8.8 on the Quantab scale which equals >644 ppm for chlorides. According to ORC 1509.072 (A) all pits containing brine and other waste shall be filled within two months of completion. The company will be advised to close pit as soon as possible. Preliminary restoration is not complete. The tank battery consists of (1) 210 barrel tank inside an earthen dike and (1) horizontal separator. Identification was not observed at the well or tank. The company previously was asked if they could try to mitigate the odor from the tank battery. They have yet to get back with me regarding the odor. The company will be asked again if there is anything they can do. Time of inspection: 10:45 AM. Weather: 68*F, Sunny |
1205274678 | 2015-11-19 | Drill / Deepen / Reopen | No Violations | An inspection of drilling operations revealed Kilbarger rig #5 drilling during inspection. The depth was approximately 636 feet. No violations. Time of inspection: 10:00 AM. Weather: 53*F, Sunny |
1296966045 | 2016-04-21 | Production Wells | No Violations | Inspect location as part of a compliance notice follow-up. Water has been pumped out of pit. Pit closure has begun. The pit was partially closed during inspection. No activity during inspection. Time of inspection: 3:20 PM. Weather: 68*F, Overcast |
1338063823 | 2015-11-17 | Drill / Deepen / Reopen | No Violations | An inspection of drilling operations revealed Kilbarger rig #5 drilling on fluid at 218 feet. No violations during inspection. Time of inspection: 4:15 PM. |
1436017470 | 2016-04-20 | Production Wells | No Violations | Inspect location as a compliance notice follow-up in regards to pit closure. Casey with Artex was on location. Pit water was being pumped out during inspection. Casey stated that pit water would be pumped out and pit closure would begin tomorrow. Time of inspection: 10:00 AM. Weather: 57*F, Sunny |
1461166437 | 2016-04-19 | Administrative Inspection | No Violations | A voice mail message was left for Gene Huck at 1:25 PM regarding pit closure and restoration. At 4:47 PM Joe Snider with Artex called and was advised that the pit needs closed as soon as possible. Mr. Snider said that pit closure would begin immediately. |
1578915167 | 2016-05-20 | Preliminary Restoration | No Violations | Inspect location as a follow-up. The pit has been closed and location final graded. Artex has indicated that the lease road will be re-routed. The restoration will be complete when current access road is reclaimed. Time of inspection: 9:00 AM. Weather: 53*F, Sunny |
1848997112 | 2015-11-20 | Casing String Witnessed | No Violations | I witnessed the cementing of the 8.63 casing on Kilbarger rig #5 for Artex Oil Company. Heath Halstead was on location for Artex. Formation Cementing was contracted to cement casing. Formation broke circulation and good cement returns were observed. Cement did not drop. A basket was not used. The cement ticket was received. Time of inspection: 7:30 AM. |
1867216860 | 2016-03-03 | Production Wells | No Violations | Inspect tank battery in regards to a phone call from adjacent landowner regarding an odor from tank. The tank battery consists of (1) 210 barrel tank inside an earthen dike and a horizontal separator outside dike. A phone call was placed to Joe Snider with Artex and it was suggested that a charcoal filter be installed. This well was drilled in a non-urban area and therefore a charcoal filter is not required. Mr. Snider said he would get back to me and will try to do something to mitigate the odor. Time of inspection: 2:00 PM. Weather: 36*F, Overcast |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1125621259 | US-OH-103176 | 2016-06-14 | Failure to legibly identify well | |
1125621259 | US-OH-103177 | 2016-06-14 | Dike or pit not able to prevent escape of brine or other wastes | |
1125621259 | US-OH-103178 | 2016-06-14 | Non urban - failure to meet tank battery setbacks from an inhabited structure |
For data sources see[9]