34-089-26185

Well Details

Well ID: 34-089-26185
Loading map...
Country: United States
State: Ohio
County: Licking
Municipality: St. Albans Township
Operator Name: KNOX ENERGY INC.
Well Pad ID:
Farm/Lease Name: LEES D & G
License Status: Producing
License Date: 2016-12-15
Spud Date: 2016-12-20
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2016-12-23
Well Total Depth: 2111.00 ft
Configuration: Vertical
Latitude: 40.080000
Longitude: -82.640000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2016-12-15 Proposed Formations:OHIO SHALE THRU QUEENSTON, Issued Date:12/15/2016, Expired Date:12/15/2018 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2016-12-23
Completion Report Received 2017-04-24
Record Last Modified 2017-11-16
Construction Permit Expires 2018-12-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2017-04-25 1968 1973 11
1968 1973 11
1968 1973 11

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2017-02-23 ACID 15 52996 Gal 0 Producers Service Corporation SEE IMAGES

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2017 KNOX ENERGY INC. 0.00 543.00 365
2018 KNOX ENERGY INC. 0.00 802.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2017 KNOX ENERGY INC. Brine 374 365
2018 KNOX ENERGY INC. Brine 50 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1836481933 2017-6-19 0:00: PL No Violations 0.20
-220346255 2020-7-27 0:00: PW No Violations 0.50
-396965544 2017-2-23 0:00: CT No Violations 4.00
-844001702 2017-1-31 0:00: PL No Violations
0396965544 2017-02-23 Completion Testing No Violations I was on location today to witness the frac job on this well. After the rig crew swabbed the well dry Producers Service Corp spotted 300 gallons of acid to treat the well. The depth of th 4.5 inch casing was set at 2,032 feet and perforated from 1968-1973 feet with 11 shots. The 5 minute shut in pressure was 735 pounds.
0844001702 2017-01-31 Preliminary Restoration No Violations Inspect location as a status check. No personnel on location during inspection. The well has been drilled. The drilling rig and equipment has been removed. The mud and air pits have not been closed as of this date. The pit liners are intact and containing fluid. A 4.5 inch to 2 inch swage with a valve shut-in was observed on the well. No violations. Time of inspection: 9:45 AM.
1482422864 2016-12-22 Drill / Deepen / Reopen No Violations I wintessed surface casing for this well. I witnessed the 8.62 casing being ran and 270 sacks of cement was used to bring the cement back to surface.
1482424098 2016-12-21 Casing String Witnessed No Violations Witnessed surface casing run and cementing operations with inspectors Kip Thompson and Brandon Mitchell.
1836481933 2017-06-19 Preliminary Restoration No Violations This inspection was conducted as a preliminary restoration status check. The well was equipped with a pumping unit and motor. It was pumping during inspection. The well location has been restored and the pits have been closed. Good vegetative growth was observed. The tank battery consists of (1) 210 barrel tank, (1) 100 barrel tank, and a separator inside an earthen dike. Identification was posted at the tank battery. Inspection meets ORC 1509.072 requirements. No violations. Time of inspection: 1:45 PM. Weather: 80*F, Partly cloudy
985735216 2020-7-27 0:00: PW No Violations 0.50

For data sources see[9]

References