If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-093-20483 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.22,"lon":-82.19,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lorain | |
Municipality: Pittsfield Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: MCCONNELL WD | |
License Status: Storage Well | |
License Date: | |
Spud Date: 1947-05-16 | |
Spud Drilling Contractor: | |
Final Drill Date: 1947-06-17 | |
Well Total Depth: 2215.00 ft | |
Configuration: Vertical | |
Latitude: 41.220000 | |
Longitude: -82.190000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1947-05-16 | GL=804.7 |
Completed | 1947-06-17 | GL=804.7 |
Reached Total Depth | 1947-06-17 | GL=804.7 |
Record Last Modified | 2013-04-10 | GL=804.7 |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2017-09-11 | FOAM | 0 | 300 Bbl | 22454 | Reliance Well Service | Reliance Well Service arrived on location at 12:00 and rigged up on the Workover Solutions wellhead isolation tool. A pre job tailgate meeting was held. The stimulation was a 20% Nitrogen assisted foam fracture. API 20/40 sand was used. 500 gallons of 15% hydrochloric acid was pumped ahead of the slurry. The slurry consisted of cross linked fresh water gel. 70,507 cubic feet of nitrogen was used in the job. The surface production annulus was open during the job. Initial reservoir pressur |
0 | 0 | 0 |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2001 | COLUMBIA GAS TRANSMISSION LLC | 0.00 | 0.00 | 0 |
2002 | COLUMBIA GAS TRANSMISSION LLC | 0.00 | 0.00 | 0 |
2003 | COLUMBIA GAS TRANSMISSION LLC | 0.00 | 0.00 | 0 |
2004 | COLUMBIA GAS TRANSMISSION LLC | 0.00 | 0.00 | 0 |
2005 | COLUMBIA GAS TRANSMISSION LLC | 0.00 | 0.00 | 0 |
2006 | COLUMBIA GAS TRANSMISSION LLC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2001 | COLUMBIA GAS TRANSMISSION LLC | Brine | 0 | 0 |
2002 | COLUMBIA GAS TRANSMISSION LLC | Brine | 0 | 0 |
2003 | COLUMBIA GAS TRANSMISSION LLC | Brine | 0 | 0 |
2004 | COLUMBIA GAS TRANSMISSION LLC | Brine | 0 | 0 |
2005 | COLUMBIA GAS TRANSMISSION LLC | Brine | 0 | 0 |
2006 | COLUMBIA GAS TRANSMISSION LLC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1103363388 | 2014-1-22 0:00: | SO | No Violations | |
-1167329702 | 2018-5-16 0:00: | SO | No Violations | |
-1476354636 | 2013-2-12 0:00: | SO | No Violations | |
-643068071 | 2015-1-5 0:00:0 | SO | No Violations | |
-705093440 | 2013-12-9 0:00: | SO | No Violations | |
0163368919 | 2017-12-29 | Storage Well | No Violations | Performed annual inspection for Columbia Gas Storage Well #8400 on 12/29/2017. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, a drip, and 1-10 bbl fiberglass tank. Well identification is clearly displayed. No problems were noted at the time of the inspection. |
0610789492 | 2016-02-02 | Storage Well | No Violations | Inspected Columbia Gas Storage Well #8400 on 02/02/2016. The well is equipped with a flanged wellhead with a drip tank, and 1-10 bbl fiberglass tank. No dike is present. Tyler Small, Columbia Gas Team Leader, was notified of this issue and will have it addressed promptly. Well identification is clearly displayed. No other problems were noted at the time of the inspection. |
0643068071 | 2015-01-05 | Storage Well | No Violations | Performed annual inspection for Columbia Gas Storage Well #8400 on 01/05/2015. The well is equipped with a wellhead with a drip tank and 1-10 bbl fiberglass tank located within a shallow earthen dike. Well identification is posted, but the API Number listed is incorrect. Tyler Small, Columbia Gas Team Leader, was notified of this issue and will address it promptly. No other problems were noted at the time of the inspection. |
0705093440 | 2013-12-09 | Storage Well | No Violations | Performed annual storage well inspection for Columbia Gas Storage Well #8400 on 12/09/2013. Well is equipped with 1-10 bbl plastic tank. Well identification is posted but is too faded to read. No other problems were noted at the time of the inspection. |
1103363388 | 2014-01-22 | Storage Well | No Violations | Performed annual inspection for Columbia Gas Storage Well# 8400 on 01/22/2014. Well is equipped with a drip tank and 1-10 bbl plastic tank. Well identification is posted, but it is very faded and lacks an API Number and Township. No other problems were noted at the time of the inspection. |
1167329702 | 2018-05-16 | Storage Well | No Violations | Conducted annual inspection for this Columbia Gas Storage Well #8400. This well is equipped with a wellhead with 1-master valve and 1-wing valve, a drip tank, and 1-10 bbl. fiberglass tank. Well identification is clearly displayed. No compliance issues were found at the time of this inspection. |
1476354636 | 2013-02-12 | Storage Well | No Violations | I inspected Columbia Gas Transmission storage well # 8400 today. The well is located in the Wellington Storage Field, Pittsfield Township, Lorain County, Ohio. The well is equipped with a main valve, side valve with a 3.00 line plumbed to the drip tank. There is a 1.00 line from the drip tank to a 10 BBL storage tank. All lids and hatches are closed and secure. The well is properly tagged and is identified with a clear, legibly marked well identification sign mounted on the drip tank. No violations found. |
1505146359 | 2017-09-11 | Storage Well | No Violations | The operator requested inspection to witness fracture stimulation of the storage well. See the job ticket for details. Reliance Well Service conducted the stimulation. Terry VanSickle of Columbia Gas on location. Key and Workover Solutions on location. Mac Oil provided water tanks and water. |
163368919 | 2017-12-29 0:00 | SO | No Violations | |
610789492 | 2016-2-2 0:00:0 | SO | No Violations | |
710742822 | 2019-9-20 0:00: | SO | No Violations |
For data sources see[8]