Well ID: 34-095-60033 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.52,"lon":-83.71,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lucas | |
Municipality: Waterville Township | |
Operator Name: LANDOWNER GRANT PROGRAM 2007 | |
Well Pad ID: | |
Farm/Lease Name: NORFOLK & SOUTHERN CORP | |
License Status: Final Restoration | |
License Date: 2006-12-29 | |
Spud Date: | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: | |
Configuration: Vertical | |
Latitude: 41.520000 | |
Longitude: -83.710000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 2006-04-03 | INSPECTED BY KEN PIISPANEN ON FEBRUARY 16, 2006. REC'D A CALL FROM STEVE PARSONS, WATERVILLE FFIRE DEPARTMENT CHIEF. THIS WELL IS LEAKING GAS. |
APP | 2006-12-29 | Proposed Formations:TRENTON, Issued Date:12/29/2006, Expired Date:12/29/2007 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class: |
Plugged by Orphan Well Program | 2007-04-05 | Plugged by Orphan Well Program |
Plugged/Abandoned | 2007-04-05 | INSPECTED BY KEN PIISPANEN ON FEBRUARY 16, 2006. REC'D A CALL FROM STEVE PARSONS, WATERVILLE FFIRE DEPARTMENT CHIEF. THIS WELL IS LEAKING GAS.
I&O CN 2006 07 042 |
Construction Permit Expires | 2007-12-29 | INSPECTED BY KEN PIISPANEN ON FEBRUARY 16, 2006. REC'D A CALL FROM STEVE PARSONS, WATERVILLE FFIRE DEPARTMENT CHIEF. THIS WELL IS LEAKING GAS.
I&O CN 2006 07 042 |
Record Last Modified | 2013-03-14 | INSPECTED BY KEN PIISPANEN ON FEBRUARY 16, 2006. REC'D A CALL FROM STEVE PARSONS, WATERVILLE FFIRE DEPARTMENT CHIEF. THIS WELL IS LEAKING GAS.
I&O CN 2006 07 042 |
For data sources see[2]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
1175186430 | 2007-03-29 | Orphan | No Violations | Operator on site. Access has been made from Dutch Road across old railroad bed to well. Old oil and gas rig that was near well has been removed. Well is gas only with 4 inch pipe and 8 inch conductor pipe. Odor of sour gas around well and gas ignited on top of casing when flame placed above casing. . Bob said obstruction was encountered at approximatelt 260 feet. Will move equipment in today and begin cleaning out well next week. Well will be allowed to vent until then but valve will be placed on casing so open well casing is not exposed. |
1175697797 | 2007-04-04 | Plug / Plug Back | No Violations | Well appeared to be primarily a gas well. Only a small amount of oil was encountered. Pumped 100 sacks of cement into well thru 1110 feet of tubing to bottom of well which was approximately 1110 feet deep. Water circulated to tank. There is 4 inch and 6 inch pipe in the well as well as 8 inch conductor pipe. Todays cement was for bottom plug. The 4 inch pipe will be removed before cement is ordered for top plug. |
1175793633 | 2007-04-05 | Plug / Plug Back | No Violations | Cement pumped on 4/4/07 set at 410 feet below ground elevation. Operator removed 280 feet of 4 inch pipe including packer. Pumped 83 sacks of cement into well until cement circulated in tank. Cement settled in pipe approximately 1 foot below top of pipe. Discussed seeding and restricting access to site. |
1181766869 | 2007-06-13 | Orphan | No Violations | Checked site for final restoration. Entry way has been seeded and vegetation growing. The access lane cleared to the site was on an old railroad bed and has adequate stone on the surface. Site has been graded and all equipment removed. |