Well Details

Well ID: 34-099-20972
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Knox Township
Operator Name: BRINEAWAY INC
Well Pad ID:
Farm/Lease Name: SALTY DOG {SWIW #8}
License Status: Final Restoration
License Date: 2012-01-03
Spud Date: 1977-07-25
Spud Drilling Contractor: BURDETTE DRLG
Final Drill Date: 1977-08-09
Well Total Depth: 5350.00 ft
Configuration: Vertical
Latitude: 40.900000
Longitude: -81.010000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1977-07-07 134 PETROCON INC GeoDate 7/7/77
Original Spud 1977-07-25 CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92. CONVERT 12-21-91
Reached Total Depth 1977-08-09 CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92. CONVERT 12-21-91
CO 1991-12-18 134 PETROCON INC GeoDate 12/18/91
Conversion to Injector 1991-12-18
Salt Water Injection Well 1991-12-18 Issued Date 12/18/91 Expired Date 12/17/92 Acres 0000000 Tool Type NT Proposed Formation NEWBURG OR CLINTON Proposed Depth 05350 Proposed Drill Depth 05350
Storage Well 1991-12-18 Issued Date 12/18/91 Expired Date 12/17/92 Acres 0000000 Tool Type NT Proposed Formation NEWBURG OR CLINTON Proposed Depth 05350 Proposed Drill Depth 05350
Annulus Pressure Monitoring Approved 1992-05-20 CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92. CONVERT 12-21-91
First Injection 1992-06-11 CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92. CONVERT 12-21-91
CO 1992-06-20 134 PETROCON INC GeoDate 7/2/77
Completed 1992-06-20 CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92. CONVERT 12-21-91
CO 1992-07-27 2328 BRINEAWAY INC GeoDate 12/18/91
Completion Report Received 1992-08-31 CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92. CONVERT 12-21-91
Last Compliance Report 2003-05-01 CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92. CONVERT 12-21-91
Plugged/Abandoned 2011-12-14 CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92. CONVERT 12-21-91
APP 2012-01-03 Proposed Formations:QUEENSTON, Issued Date:1/3/2012, Expired Date:1/2/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:SWD, Proposed Well Class:SWIW
Construction Permit Expires 2014-01-02 CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92. CONVERT 12-21-91
Record Last Modified 2017-02-15 CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92.CONVERTED FROM OIL & GAS TO SWD IN 1991-92. CONVERT 12-21-91

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-01 5185 5232 1
2000-05-01 5223 5271 1
5185 5232 1
5223 5271 1
5185 5232 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 1800 Bbl 50000 500 GALLONS ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 EXCO - NORTH COAST ENERGY INC 1434.00 0.00 0
1985 EXCO - NORTH COAST ENERGY INC 2710.00 302.00 365
1986 EXCO - NORTH COAST ENERGY INC 2275.00 322.00 273
1987 EXCO - NORTH COAST ENERGY INC 478.00 0.00 365
1988 PETROCON INC 0.00 253.00 365
1989 PETROCON INC 0.00 85.00 365
1990 PETROCON INC 0.00 51.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 EXCO - NORTH COAST ENERGY INC Brine 100 0
1985 EXCO - NORTH COAST ENERGY INC Brine 0 365
1986 EXCO - NORTH COAST ENERGY INC Brine 100 273
1987 EXCO - NORTH COAST ENERGY INC Brine 0 365
1988 PETROCON INC Brine 890 365
1989 PETROCON INC Brine 750 365
1990 PETROCON INC Brine 335 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1052275561 2010-6-2 0:00:0 SW No Violations
-1111642525 2005-8-22 0:00: SW No Violations 0.50
-1157951457 2011-6-3 0:00:0 SW No Violations
-1339025365 2005-6-21 0:00: SW No Violations 0.50
-1435395171 2007-12-4 0:00: SW No Violations
-1486539908 2007-6-4 0:00:0 SW No Violations
-1746860302 2005-4-7 0:00:0 SW No Violations 0.50
-1805825072 2007-5-31 0:00: SW No Violations
-1932302117 2011-3-1 0:00:0 SW No Violations
-1946919677 2011-9-7 0:00:0 SW No Violations
-1980431230 2003-4-30 0:00: SW No Violations 9.50
-2061609760 2008-6-5 0:00:0 SW No Violations
-232177876 2007-6-5 0:00:0 SW No Violations
-238905326 2009-9-8 0:00:0 SW No Violations
-261267447 2010-9-9 0:00:0 SW No Violations
-295739340 2006-10-17 0:00 SW No Violations
-353133372 2005-11-16 0:00 SW No Violations 0.50
-464730441 2009-6-1 0:00:0 SW No Violations
-713346367 2009-12-1 0:00: SW No Violations
-889091583 2010-12-2 0:00: SW No Violations
000UIC1667 1997-04-18 Salt Water Injection Well No Violations 1501:9-3-07(H) EQUIPMENT FAILURE
000UIC1668 1997-04-18 Salt Water Injection Well No Violations 1501:9-3-06(H) IDENTIFICATION
000UIC1737 1998-10-13 Salt Water Injection Well No Violations 1509.03 TEST FLOWLINE
001216i104 2001-11-28 Salt Water Injection Well No Violations No violations this date. Well injecting. Last inspection date:07-31-2001.
001216i264 2002-03-04 Salt Water Injection Well No Violations No violations noted this date. Last inspection 01-02-2002. Annulus pressure not checked due to ice buildup in the valve.
001216i386 2002-04-18 Salt Water Injection Well No Violations Not running this date. Last inspection 03-04-2002.
001216i839 2002-08-14 Salt Water Injection Well Violations Noted Most of contamination removed. The company is in the process of building a new holding facility. Present this date, to observe the excavation of a pit to hold a cement vault inside the dike area for all spills. The bottom of the hole has eight inches of fire clay. The tank was then set in and the outside filled in with eight to twelve inches of fire clay with approximately four inches of the tank above ground level. The floor of the dike (45X45) was covered with gravel, fencing and iron rods. The well is shut in at this time. No pressures taken.
001216i841 2002-08-15 Salt Water Injection Well Violations Noted On site this date to observe the cementing of the storage facility base. Cement is approximately eight inches thick on the west side and eight to twelve inches on the east side. There is a gradual slope toward the buried tank from all directions. Case pends. The case will not be resolved until the new storage facility is up and running. The old facility will then be reclaimed and final removal of contamination completed.
001216i955 2002-10-17 Salt Water Injection Well Violations Noted The old storage facility has not been fully restored as yet. Three tanks remain to be emptied. Last inspection 09/24/2002. Case pends.
0063777518 2002-06-20 Salt Water Injection Well No Violations Remove and dispose of all free oil and oiled material inside the dike around the tank battery. Establish vegetation in the scald area north of the well from the last workover.Last inspection date 04/18/2002.
0102120306 2004-11-16 Salt Water Injection Well No Violations Last inspection 08/26/2004.
0162329506 2012-05-15 Final Restoration No Violations I conducted an inspection on the restoration of this site and found that the well location is in agricultural cropped field. All equipment and debris has been removed from the site and the former access road has been reclaimed with short grasses. The tank battery was shared with permit 1956 and is still in operation. This site passes final restoration.
0232177876 2007-06-05 Salt Water Injection Well No Violations This well the packer changed out on 6/4/07. A UIC was performed. The annulus was pressure tested to 1280 psi. Held the pressure for 15 minutes. The pump is being overhauled. The UIC on 6/4/07 will be the quarterly inspection. I found no violations at this time.
0238905326 2009-09-08 Salt Water Injection Well No Violations I performed the quarterly UIC test. The well was running. There were no violations at this time.
0261267447 2010-09-09 Salt Water Injection Well No Violations I performed the quarterly UIC test on the annulus and the injection. The well was not running. There were no violations at this time.
0265098911 2003-02-21 Salt Water Injection Well Violations Noted The old storage facility has not been removed and reclaimed as yet. The valve on the annulus has been replaced. Case pends. Last inspection 12-04-2002.
0295739340 2006-10-17 Salt Water Injection Well No Violations Met with Paul Shaw to discuss the minor repairs at the injection wellhead.
0353133372 2005-11-16 Salt Water Injection Well No Violations The well was last inspected 0n 08-22-2005.
0464730441 2009-06-01 Salt Water Injection Well No Violations I performed the quarterly UIC test. The well was not running. I walked around the wellhead and the tank battery and found no violations at this time
0482350756 2011-12-12 Salt Water Injection Well No Violations Inspector Rick Skidmore and myself witnessed the plugging of the Clinton zone by Petroset on Phils Well Service workover rig.
0552151705 2006-08-31 Salt Water Injection Well No Violations The system was not running at the time of the inspection. There were no violations at the wellhead or at the tank battery. The top joint of tubing in the injection well is extremely corroded and heavily rusted. It needs to be replaced. The needle valves on the annulus and on the injection tubing are barely functional. Install new needle valves. The pressure (1260 psi) on the annulus is very high for the condition of the fittings. I suggest that some of the pressure is bled off.
0678792990 2008-03-03 Salt Water Injection Well No Violations I performed the quarterly UIC test. The well was not running. The wellhead and the tank battery were GPSd. The wellhead and the tank battery were in good shape. I found no violations at this time.
0713346367 2009-12-01 Salt Water Injection Well No Violations I performed the quarterly UIC test. The well was not running. There were no violations at this time.
0889091583 2010-12-02 Salt Water Injection Well No Violations I performed the quarterly UIC test on the annulus and the injection. The well was not running. There were no violations at this time.
0972734501 2003-04-29 Salt Water Injection Well Violations Noted The old tank battery has not been removed and site restoration has not been done. On site this date for a mechanical integrity test. Unable to test. Will pull packer and rebuild. Found holes in one joint and decided to test all the pipe before running it back into the hole.
102120306 2004-11-16 0:00 SW No Violations 1.00
1039094667 2002-12-04 Salt Water Injection Well Violations Noted Old tank battery contamination not removed. Vegetation north of well site unknown due to snow cover. Annulus valve broken and needs to be replaqced. Unable to check the annulus pressure. Last inspection 10/17/2002.
1049976561 2003-04-09 Salt Water Injection Well Violations Noted Arrived on site to find that the two inch valve on the wellhead annulus had failed. Brine was running into the wellhead dike filling the dike to approximately half. The wellhead dike had failed to contain all the brine and it was escaping into the wheat field through three areas. The size of the affected area is approximately 40 X 100. Contact was made with Paul Shaw of Dorfman Production. The failed valve will be replaced. The brine will be removed from the wellhead dike. The contaminated soil in the wheat field will be removed and replaced with new top soil. The wellhead dike will be rebuilt with clay and covered with top soil to establish vegetation. The old storage tank battery has not been removed as yet. This situation should be addressed soon so as to prevent further action being taken. Due to the brine in the wellhead dike no pressures were taken this date. Will return next week to conduct pressure check and verify cleanup. Last inspection 02/21/03.
1052275561 2010-06-02 Salt Water Injection Well No Violations I performed the quarterly UIC test on the annulus and the injection. The well was not running. There were no violations at this time.
1055245181 2003-06-09 Salt Water Injection Well No Violations The old dike has been removed. All contamination has been removed. The wellhead dike has been replaced. Topsoil has been placed in the field where the contaminated soil was removed. Last inspection 04-30-2003. Recommend case be resolved.
1061833680 2003-08-21 Salt Water Injection Well No Violations The last inspection was 06/09/03.
1066326454 2003-10-16 Salt Water Injection Well No Violations The last inspection date was 08/21/03.
1072443168 2003-12-24 Salt Water Injection Well No Violations The last inspection date was 10-16-2003.
1076072381 2004-02-05 Salt Water Injection Well No Violations Last inspection 12/24/2003. No annular pressure reading this date due to frozen valve.
1093606212 2004-08-26 Salt Water Injection Well No Violations Last inspection 06/21/2004.
1111642525 2005-08-22 Salt Water Injection Well No Violations The last inspection was 06/21/2005.
1136029843 2006-02-06 Salt Water Injection Well No Violations The last inspection date was 11-16-2005.
1142775394 2017-07-26 Salt Water Injection Well No Violations I performed a status check on the above SWIW. The pump was running the injection was 675 psi the annulus was at 170 psi ID signs were posted. No violations at this time
1157951457 2011-06-03 Salt Water Injection Well No Violations I performed the quarterly UIC test on the annulus and the injection. The well was not running. There were no violations at this time.
1180619627 2007-05-30 Salt Water Injection Well No Violations GPSs tank battery and wellhead. Witnessed the unseting of the packer on this well. Well Service company is Phils Well Service. Released packer and pulled the 2 3/8 tubing out of hole. Found 1/2 hole in tubing at 2,000 feet deep. Pressure tested each joint of tubing to 2,000 psi on the rack. Changed out 20 joints of tubing. Shut down for night.
1190817834 2007-09-26 Salt Water Injection Well No Violations I performed the quarterly UIC test. GPSd both the well and tank battery. Checked the wellhead and tank battery. The injection well was not in operation. There were no violations at this time.
1216i104 2001-11-28 0:00 SW No Violations 0.80
1216i264 2002-3-4 0:00:0 SW No Violations 0.50
1216i386 2002-4-18 0:00: SW No Violations 0.50
1216i839 2002-8-14 0:00: SW No Violations 3.00
1216i841 2002-8-15 0:00: SW No Violations 3.50
1216i955 2002-10-17 0:00 SW No Violations 0.50
1228492476 2008-12-01 Salt Water Injection Well No Violations I performed the quarterly UIC test. The well was not running. I walked around the wellhead and the tank battery and found no violations at this time
1236341690 2009-03-04 Salt Water Injection Well No Violations I performed the quarterly UIC test. The well was not running. I walked around the wellhead and the tank battery and found no violations at this time
1322583596 2011-11-21 Salt Water Injection Well No Violations I received a call from Greg New about this well. It had lost mechanical integrity and the well is shut in. I called Tom Tomastik to let him know. The workover rig will be repairing this well in the next couple of weeks.
1339025365 2005-06-21 Salt Water Injection Well No Violations The last inspection was 04/07/2005.
1435395171 2007-12-04 Salt Water Injection Well No Violations I performed the quarterly UIC test. I checked the wellhead and tank battery. The injection well was not in operation. There were no violations at this time.
1451794885 2008-09-08 Salt Water Injection Well No Violations I performed the quarterly UIC test. The well was not running. I walked around the wellhead and the tank battery and found no violations at this time
1486539908 2007-06-04 Salt Water Injection Well No Violations I witnessed the Halliburton R-4 packer going into the well with new rubber and slips. Ran 163 joints(5097) of 2 3/8 tubing. Set at 5107.20KB. Packer set in 10,000# tension. Rigged up Petroset. Petroset pumped 55 barrels of water mixed with corrosion inhibitor (Chem Tech 700). The fluid was pumped down the annulus. I witnessed the pressure testing of the annulus to 1280 psi. Lost 0psi in 15 minutes. This well hass PASSED UIC test.
162329506 2012-5-15 0:00: FR No Violations
1662075477 2005-04-06 Salt Water Injection Well Violations Noted Found the well injection pressure at 1,380 psi. Made contact with Greg New and had the well shut in.
1678457011 2010-03-01 Salt Water Injection Well No Violations I performed the quarterly UIC test. The well was running. The snow was deep. There were no violations at this time.
1704044767 2007-02-13 Production Wells No Violations Performed a status check on the well and tank battery. Needle valves have not been replaced. Called Paul Shaw, 330-284-2045 and discussed my findings. He will notify my when the new needle valves are installed.
1709716387 2006-05-01 Salt Water Injection Well No Violations The last inspection was 02-06-06.
1746860302 2005-04-07 Salt Water Injection Well No Violations The pressure is now below maximum injection pressure. Recommend case be resolved.
1747592855 2011-09-07 Salt Water Injection Well No Violations I performed the quarterly UIC test on the annulus and the injection. The well was not running. There were no violations at this time.
1751754286 2007-03-21 Salt Water Injection Well No Violations Dave Claus and I went to perform the quarterly UIC test. Checked the wellhead . The injection well was not in operation. The well was off. There were no violations at this time.
1785521869 2005-02-09 Salt Water Injection Well No Violations The last inspection was 11-16-2004.
1805825072 2007-05-31 Salt Water Injection Well No Violations I did not witness the reconditioned Halliburton R-4 packer with 2 shear buttons, going in the well. I was finishing up a surface job. Ran in hole with 164 joints of 2 3/8 tubing(5128.60). Set at 5138.60 KB. Set packer in 10,000# tension. Secure wellhead. Rig up water truck and pumped 55 barrels of water and corrosion inhibitor (Chem-Tech 770) down the annulus. Finished pumping. Fluid coming up annulus. Tried to reset packer. Packer would not reset. Came up hole 1 joint to 5107.20. Packer still would not set. Started tripping out of hole. Shut down for night.
1912724572 2004-06-21 Salt Water Injection Well No Violations The last inspection was 04-14-04.
1932302117 2011-03-01 Salt Water Injection Well No Violations I performed the quarterly UIC test on the annulus and the injection. The well was not running. There were no violations at this time.
1946919677 2011-09-07 Salt Water Injection Well No Violations ID sign posted at well head and tank battery, dike free of oil/brine/debris. No leaks or spills. No violations at this time.
1980431230 2003-04-30 Salt Water Injection Well Violations Noted On site today to perform a mechanical integrity test (MIT). Ran tubing and packer into the hole, set the packer and pressured up to 1410 psi. Did not lose any pressure for the fifteen minute test. The contamination will be removed and the old tank battery removed and restored within the next month.
2061609760 2008-06-05 Salt Water Injection Well No Violations I performed the quarterly UIC test. The well was running. The wellhead and the tank battery were in good shape. I found no violations at this time.
265098911 2003-2-21 0:00: SW No Violations 1.00
482350756 2011-12-12 0:00 SW No Violations
552151705 2006-8-31 0:00: SW No Violations
63777518 2002-6-20 0:00: SW No Violations 0.50
678792990 2008-3-3 0:00:0 SW No Violations
972734501 2003-4-29 0:00: SW No Violations 3.00
UIC1667 1997-4-18 0:00: SW No Violations
UIC1668 1997-4-18 0:00: SW No Violations
UIC1737 1998-10-13 0:00 SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
001216i839 US-OH-105559 2002-08-15 Pollution/Contamination
001216i841 US-OH-105560 2002-08-15 Pollution/Contamination
001216i955 US-OH-105822 2002-10-17 Contamination at surface facility (permit after 6-1-82)
0265098911 US-OH-122734 2003-02-26 Contamination at surface facility (permit after 6-1-82)
0972734501 US-OH-131153 2003-05-05 Pollution/Contamination
1039094667 US-OH-100550 2002-12-05 Pollution/Contamination
1039094667 US-OH-100551 2002-12-05 Violation of injection tubing/fitting requirements
1049976561 US-OH-100816 2003-04-10 Mechanical failure/contamination
1662075477 US-OH-116435 2005-04-07 Exceeding maximum allowable injection pressure
1980431230 US-OH-120035 2003-05-05 Pollution/Contamination

For data sources see[9]

References