34-099-21116

Well Details

Well ID: 34-099-21116
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Goshen Township
Operator Name: PETROX, INC
Well Pad ID:
Farm/Lease Name: GOTTSCHALL TOOL & DIE INC
License Status: Final Restoration
License Date: 2006-11-15
Spud Date: 1980-05-19
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1980-05-24
Well Total Depth: 5597.00 ft
Configuration: Vertical
Latitude: 40.960000
Longitude: -80.910000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-05-14 140 KST OIL & GAS CO INC GeoDate 5/14/80
Original Spud 1980-05-20
Completed 1980-05-24
Reached Total Depth 1980-05-24
CO 1995-12-05 182 BELDEN & BLAKE CO GeoDate 5/14/80
Change of Owner 2002-08-07 Operator changed from 182, BELDEN & BLAKE CORPORATION to 1966, PETROX INC
APP 2006-11-15 Proposed Formations:CLINTON, Issued Date:11/15/2006, Expired Date:11/15/2007 6:00:00 AM, Drilling unit acres:73.42, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2006-12-15
Construction Permit Expires 2007-11-15
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2003-06-17 5360 5424 18
2006-09-11 5860 5424 18
5360 5424 18
5860 5424 18
5360 5424 18

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 120000 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 GM/DELPHI PACKARD ELEC. 13309.00 128.00 0
1995 BELDEN & BLAKE CORPORATION 181.00 0.00 67
1996 BELDEN & BLAKE CORPORATION 1244.00 219.00 366
1997 BELDEN & BLAKE CORPORATION 1977.00 133.00 358
1998 BELDEN & BLAKE CORPORATION 1204.00 256.00 362
1999 BELDEN & BLAKE CORPORATION 1102.00 131.00 351
2000 BELDEN & BLAKE CORPORATION 717.00 186.00 366
2001 BELDEN & BLAKE CORPORATION 996.00 113.00 321
2002 PETROX, INC 486.00 0.00 0
2003 PETROX, INC 0.00 0.00 0
2004 PETROX, INC 0.00 0.00 0
2005 PETROX, INC 301.00 0.00 365
2006 PETROX, INC 490.00 0.00 154

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 GM/DELPHI PACKARD ELEC. Brine 0 0
1995 BELDEN & BLAKE CORPORATION Brine 0 67
1996 BELDEN & BLAKE CORPORATION Brine 52 366
1997 BELDEN & BLAKE CORPORATION Brine 18 358
1998 BELDEN & BLAKE CORPORATION Brine 28 362
1999 BELDEN & BLAKE CORPORATION Brine 11 351
2000 BELDEN & BLAKE CORPORATION Brine 33 366
2001 BELDEN & BLAKE CORPORATION Brine 11 321
2002 BELDEN & BLAKE CORPORATION Brine 39 190
2003 PETROX, INC Brine 0 0
2004 PETROX, INC Brine 0 0
2005 PETROX, INC Brine 140 365
2006 PETROX, INC Brine 0 154

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1108250409 2007-05-16 Final Restoration No Violations Performed a final inspection on location. Debris is gone. Production equipment, stock tanks are gone. Pits are closed. Road restored. Vegetation is starting to grow. Owner of the Tool and Die company told me he signed a wavier for the production equipment to be left in ground. He has a septic system that is around the production line. He signed the wavier yesterday. So this location does need a wavier. This well does not pass final restoration.
1181591504 2007-06-11 Final Restoration No Violations Performed a final restoration inspection. Vegetation was growing. Debris was gone from location. Production equipment was gone. Lease road restored. Drilling equipment gone. A wavier is included in the final restoration. This well and tank battery has PASSED FINAL RESTORATION.
1903494037 2006-12-14 Plug / Plug Back No Violations Pulled rods. Pumped the Clinton plug thru tubing. Will pull out all the tubing. Will rip casing tomorrow morning.

For data sources see[9]