If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-099-21289 | ![]() Sorry, we have no imagery here. Sorry, we have no imagery here. ![]() |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Berlin Township | |
Operator Name: CONSORTIUM ENERGY LLC | |
Well Pad ID: | |
Farm/Lease Name: ESHLER | |
License Status: Producing | |
License Date: 1980-10-16 | |
Spud Date: 1981-05-28 | |
Spud Drilling Contractor: | |
Final Drill Date: 1981-06-08 | |
Well Total Depth: 5091.00 ft | |
Configuration: Vertical | |
Latitude: 41.000000 | |
Longitude: -80.990000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1981-05-28 | R.I. 5-28-81 UPDATE LOCATION PER DOGRM SURVEYOR, ALE 2/12/18. |
Completed | 1981-06-08 | R.I. 5-28-81 UPDATE LOCATION PER DOGRM SURVEYOR, ALE 2/12/18. |
Reached Total Depth | 1981-06-08 | R.I. 5-28-81 UPDATE LOCATION PER DOGRM SURVEYOR, ALE 2/12/18. |
CO | 1991-06-20 | 121 HORTIN & HUFFMAN PET GEOL |
Change of Owner | 2000-08-28 | Operator changed from 121, HORTIN & HUFFMAN PET GEOL to 6791, NORMAN D INVESTMENTS |
Record Last Modified | 2018-02-12 | R.I. 5-28-81 UPDATE LOCATION PER DOGRM SURVEYOR, ALE 2/12/18. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4951 | 5015 | 22 |
4951 | 5015 | 22 | |
4951 | 5015 | 22 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1548 Bbl | 50000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1983 | HORTIN & HUFFMAN PET GEOL | 6714.00 | 919.00 | 365 |
1984 | HORTIN & HUFFMAN PET GEOL | 12382.00 | 1780.00 | 0 |
1985 | HORTIN & HUFFMAN PET GEOL | 5807.00 | 719.00 | 365 |
1986 | HORTIN & HUFFMAN PET GEOL | 50.00 | 573.00 | 365 |
1988 | ENOLD WALTER (COEN) | 7751.00 | 1042.00 | 366 |
1989 | RUFFNER PETROLEUM CORP | 3621.00 | 506.00 | 365 |
1990 | RUFFNER PETROLEUM CORP | 3121.00 | 453.00 | 265 |
1991 | HORTIN & HUFFMAN PET GEOL | 13.00 | 265.00 | 365 |
1992 | HORTIN & HUFFMAN PET GEOL | 3721.00 | 735.00 | 365 |
1993 | HORTIN & HUFFMAN PET GEOL | 4113.00 | 687.00 | 365 |
1994 | HORTIN & HUFFMAN PET GEOL | 4321.00 | 647.00 | 301 |
1995 | HORTIN & HUFFMAN PET GEOL | 4355.00 | 656.00 | 345 |
1996 | HORTIN & HUFFMAN PET GEOL | 4016.00 | 532.00 | 310 |
1997 | HORTIN & HUFFMAN PET GEOL | 3593.00 | 495.00 | 360 |
1998 | HORTIN & HUFFMAN PET GEOL | 1695.00 | 242.00 | 360 |
1999 | HORTIN & HUFFMAN PET GEOL | 2561.00 | 424.00 | 365 |
2000 | HORTIN & HUFFMAN PET GEOL | 626.00 | 0.00 | 228 |
2002 | CONSORTIUM ENERGY LLC | 0.00 | 0.00 | 0 |
2003 | CONSORTIUM ENERGY LLC | 0.00 | 0.00 | 0 |
2004 | CONSORTIUM ENERGY LLC | 315.00 | 0.00 | 365 |
2005 | CONSORTIUM ENERGY LLC | 164.00 | 0.00 | 365 |
2006 | CONSORTIUM ENERGY LLC | 349.00 | 0.00 | 365 |
2007 | CONSORTIUM ENERGY LLC | 30.00 | 0.00 | 365 |
2008 | CONSORTIUM ENERGY LLC | 238.00 | 0.00 | 365 |
2014 | CONSORTIUM ENERGY LLC | 0.00 | 0.00 | 0 |
2015 | CONSORTIUM ENERGY LLC | 0.00 | 0.00 | 0 |
2016 | CONSORTIUM ENERGY LLC | 0.00 | 0.00 | 0 |
2017 | CONSORTIUM ENERGY LLC | 1749.00 | 150.00 | 360 |
2018 | CONSORTIUM ENERGY LLC | 1849.00 | 120.00 | 360 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1412440768 | 2007-8-27 0:00: | PW | No Violations | |
-2013821518 | 2017-12-26 0:00 | PW | No Violations | 1.00 |
-605143423 | 2018-6-25 0:00: | PW | No Violations | 0.30 |
000PL13248 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0062727393 | 2007-08-06 | Production Wells | No Violations | I inspected the well and tank battery. The ID sign was not up. I called Mark Liberger(330-352-1957) about the ID signs. He told me that the signs were ordered and that they should be in by next week. He also wants to paint the tank battery and spray the weeds again. |
0605143423 | 2018-06-25 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check on well #2-1289. RBDMS indicated reported production was current. Access to the location remained stable and drivable. Correct identification was present. The 8.625 well head was below grade. The 4.5 casing was equipped with an electric pump jack. Production valves were in the open position. Staining consistent with a legacy operation was present. The drive belts were off of the unit. The tank battery was shared with #2-1290. A stable earthen dike was present around the production equipment. Equipment on location consisted of one (1) horizontal separator, one (1) 100 bbl steel production tank and one (1) 50 bbl poly brine tank. The separator remained in good repair. Production was not metered at the battery. The steel production tank exhibited exterior corrosion but remained in good repair with correct identification. Valves were closed and plugged. The poly brine tank remained in good repair. The inlet valve was closed. No violations were observed during this inspection. |
1064718492 | 2020-1-2 0:00:0 | PW | No Violations | 1.00 |
1157855773 | 2007-06-19 | Production Wells | Violations Noted | Performed a random well inspection and found this well and tnnk battery had no ID signs and needed general house cleaning done. GPSd well and tank battery.Called Steve Opritza to find out the true owner. He said it would be Mark Liberger, 330-352-1957. Left 2 messages with Mr. Liberger. Called Dave C. He said his owner was Steve Svetlic. I called Steve Opritza back and left him a message. Also called Erica Freeman and left her a message. |
1412440768 | 2007-08-27 | Production Wells | No Violations | I checked the tank battery for ID signs. None yet. I called Mark Liberger, 330-352-1957. Left him a message about the ID signs. |
1865922405 | 2007-07-23 | Production Wells | Violations Noted | I checked on the tank battery and well. Weeds had been cleaned up. Called Mark Liberger about ID signs. He said that he is having signs made up. He is also going to paint the tank battery. Will give him an extension on the job. |
2013821518 | 2017-12-26 | Production Wells | No Violations | I performed a status check on the above location. The well is equipped with pumping with an electric motor. The tank battery is equipped with one 100 barrel tank and one 35 barrel poly tank and one horizontal separator. OD sigs are posted. No noted violations at this time. I called Jeremy Kohler (330-718-6335) the pumper and ask him to update his tank stickers as soon as the weather permits. |
62727393 | 2007-8-6 0:00:0 | PW | No Violations | |
PL13248 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1157855773 | US-OH-104162 | 2007-06-22 | Failure to legibly identify well | |
1865922405 | US-OH-118691 | 2007-08-08 | Failure to legibly identify well |
For data sources see[9]