X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-099-22374

Well Details

Well ID: 34-099-22374
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Boardman Township
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: BOULEVARD
License Status: Producing
License Date: 1991-12-31
Spud Date: 1990-01-05
Spud Drilling Contractor: SHERMAN DRLG
Final Drill Date: 1990-06-20
Well Total Depth: 5609.00 ft
Configuration: Vertical
Latitude: 41.020000
Longitude: -80.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1989-11-22 2456 SIMCO EXPLORATION CORP GeoDate 11/22/89
Oil and Gas 1989-11-22 Issued Date 11/22/89 Expired Date 11/22/90 Acres 0045380 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05609 Proposed Drill Depth 05609
Original Spud 1990-01-05 REVISE UNIT 1-4-92
Completed 1990-06-20 REVISE UNIT 1-4-92
Reached Total Depth 1990-06-20 REVISE UNIT 1-4-92
Completion Report Received 1990-11-13 REVISE UNIT 1-4-92
CO 1991-12-31 2456 SIMCO EXPLORATION CORP GeoDate 12/31/91
Oil and Gas 1991-12-31 Issued Date 12/31/91 Expired Date 12/30/92 Acres 0040289 Tool Type RTAF Proposed Formation CLINTON Proposed Depth Proposed Drill Depth
Construction Permit Expires 1992-12-30 REVISE UNIT 1-4-92
Record Last Modified 2017-02-15 REVISE UNIT 1-4-92

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5337 5512 0
5337 5512 0
2006-09-11 5406 5507 23
5406 5507 23
5337 5512 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 110000 Gal 80000 FRAC:WATER/SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1990 OHIO VALLEY ENERGY SYSTEMS COR 27139.00 0.00 159
1991 OHIO VALLEY ENERGY SYSTEMS COR 47691.00 0.00 338
1992 OHIO VALLEY ENERGY SYSTEMS COR 33258.00 0.00 365
1993 OHIO VALLEY ENERGY SYSTEMS COR 24609.00 0.00 365
1994 OHIO VALLEY ENERGY SYSTEMS COR 17740.00 0.00 365
1995 OHIO VALLEY ENERGY SYSTEMS COR 19149.00 0.00 365
1996 OHIO VALLEY ENERGY SYSTEMS COR 14809.00 0.00 364
1997 OHIO VALLEY ENERGY SYSTEMS COR 14719.00 0.00 364
1998 OHIO VALLEY ENERGY SYSTEMS COR 14970.00 0.00 357
1999 OHIO VALLEY ENERGY SYSTEMS COR 10093.00 0.00 365
2000 OHIO VALLEY ENERGY SYSTEMS COR 9616.00 0.00 365
2001 OHIO VALLEY ENERGY SYSTEMS COR 9608.00 0.00 364
2002 OHIO VALLEY ENERGY SYSTEMS COR 10524.00 0.00 364
2003 OHIO VALLEY ENERGY SYSTEMS COR 8586.00 0.00 364
2004 OHIO VALLEY ENERGY SYSTEMS COR 7964.00 0.00 364
2005 OHIO VALLEY ENERGY SYSTEMS COR 7225.00 0.00 364
2006 OHIO VALLEY ENERGY SYSTEMS COR 7477.00 0.00 364
2007 EXCO - NORTH COAST ENERGY INC 2445.00 0.00 365
2008 OHIO VALLEY ENERGY SYSTEMS COR 5709.00 0.00 365
2009 OHIO VALLEY ENERGY SYSTEMS COR 5812.00 0.00 365
2010 OHIO VALLEY ENERGY SYSTEMS COR 5686.00 0.00 365
2011 OHIO VALLEY ENERGY SYSTEMS COR 7548.00 0.00 365
2012 OHIO VALLEY ENERGY SYSTEMS COR 5874.00 0.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 3343.00 0.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 4312.00 0.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 7200.00 0.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 7325.00 0.00 365
2017 OHIO VALLEY ENERGY SYSTEMS COR 6644.00 0.00 365
2018 OHIO VALLEY ENERGY SYSTEMS COR 4914.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1990 OHIO VALLEY ENERGY SYSTEMS COR Brine 110 159
1991 OHIO VALLEY ENERGY SYSTEMS COR Brine 201 338
1992 OHIO VALLEY ENERGY SYSTEMS COR Brine 61 365
1993 OHIO VALLEY ENERGY SYSTEMS COR Brine 26 365
1994 OHIO VALLEY ENERGY SYSTEMS COR Brine 7 365
1995 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
1996 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 364
1997 OHIO VALLEY ENERGY SYSTEMS COR Brine 4 364
1998 OHIO VALLEY ENERGY SYSTEMS COR Brine 45 357
1999 OHIO VALLEY ENERGY SYSTEMS COR Brine 37 365
2000 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2001 OHIO VALLEY ENERGY SYSTEMS COR Brine 23 364
2002 OHIO VALLEY ENERGY SYSTEMS COR Brine 12 364
2003 OHIO VALLEY ENERGY SYSTEMS COR Brine 23 364
2004 OHIO VALLEY ENERGY SYSTEMS COR Brine 19 364
2005 OHIO VALLEY ENERGY SYSTEMS COR Brine 38 364
2006 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 364
2007 EXCO - NORTH COAST ENERGY INC Brine 17 365
2008 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 46 365
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 35 365
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1543558733 2005-4-28 0:00: PW No Violations 0.50
-487510699 2007-9-25 0:00: PW No Violations
000PL12471 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0487510699 2007-09-25 Production Wells No Violations I received a call from Mrs. Marlene Carney in Boardman(330-758-7830). She complained that she had been smelling gas from the tank battery in the back of her yard. I went to the tank battery for a quick check. I could not smell any gas. I proceeded to Mrs. Carneys house. Her husband was there too. They stated about 4 times a year the smell gets so bad that one time they left the house. I inspected the tank battery which houses permit numbers 2986, 2976, 2374, 2823. I inspected inside of the tank battery. It had a privacy fence around it and was locked. The tank battery had the charcoal canister, a pressure differential valve, a Murphy switch and then the pop off. I called Don Nething from Ohio Valley. He stated that all the safety valves were in the tank battery. One well does make a lot of oil. The transportation of that oil may cause the smell. Ohio Valley owns the apartments next to the tank battery. I asked the care takers if they had any complaints about the gas smell. They had not heard of any. Mr. Nething also stated that he has not of any complaints from the apartment complex. Mr. Nething suggested that Mr. And Mrs. Carney write down the times, dates of the gas smell so he can maybe find out what Ohio Valley is doing to the tank battery at that time. I told the Carneys of the plan. They both agreed that they would do that and call me when they had some times and dates. This case is resolved.
0654598959 2018-04-25 Production Wells No Violations The purpose of my inspection was to conduct a status check inspection on well #2-2374. Inspector John Fleming was present during the inspection. RBDMS indicated reported production was current. Access to the well and tank battery remained stable and drivable. The well head was enclosed by a locked chain-link fence enclosure with green plastic privacy shielding. Correct identification was present on the fence. The 8.625 well head was at grade. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. No leaks were observed. The tank battery was shared with #2986, 2823 and 2979. A stable earthen dike that was free of fluid was present around the production equipment. A locked chain-link fence enclosure with green plastic privacy shielding that contained correct identification for all wells produced into the battery was present on the fence. Equipment within the dike consisted of four (4) horizontal separators, one (1) 140 bbl production tank, one (1) 50 bbl brine tank and one (1) 50 bbl production tank. The separator for 2374 remained in good repair and contained a current production chart. Production was shut in at the time of inspection. The production tank exhibited signs of corrosion and production fluid was staining the body of the tank. The fluid was not live or mobile. The tank was vented into a charcoal filter. The hatch lid was secured. A lightening arrestor was in place. Valves were closed and plugged. The brine tank remained in good repair. I will contact the operator to discuss the status of the production tank.
1543558733 2005-04-28 Production Wells Violations Noted The tank battery is shared with permit 2823 and consists of 2-50 bbl storage tanks, 2-separators a fence and a dike that is open on the east. Talked to Dale to get corrected.
1988079117 2007-05-03 Production Wells Violations Noted This inspection was due to the Boardman Township Fire Departments request. Well and tank battery were GPSd. ID sign was not posted. Called Don Nething(330-283-5758) and let him know that a ID sign needs to be posted at well and tank battery. Will check back next week.
2114502174 2005-06-02 Production Wells No Violations Identification is now posted. Recommend case be resolved.
654598959 2018-4-25 0:00: PW No Violations 0.30
PL12471 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1543558733 US-OH-114912 2005-04-29 Failure to legibly identify well
1988079117 US-OH-120154 2007-05-04 Failure to legibly identify well

For data sources see[9]

References