If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-099-22530 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.02,"lon":-80.64,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Boardman Township | |
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR | |
Well Pad ID: | |
Farm/Lease Name: WFMJ | |
License Status: Producing | |
License Date: 1992-04-23 | |
Spud Date: 1992-05-07 | |
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]] | |
Final Drill Date: 1992-05-16 | |
Well Total Depth: 5705.00 ft | |
Configuration: Vertical | |
Latitude: 41.020000 | |
Longitude: -80.640000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1992-04-23 | 2456 SIMCO EXPLORATION CORP GeoDate 4/23/92 |
Oil and Gas | 1992-04-23 | Issued Date 4/23/92 Expired Date 4/23/93 Acres 0042000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05705 Proposed Drill Depth 05705 |
Original Spud | 1992-05-08 | |
Completed | 1992-05-16 | |
Reached Total Depth | 1992-05-16 | |
Completion Report Received | 1992-11-12 | |
Construction Permit Expires | 1993-04-23 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2001-03-15 | 5506 | 5558 | 25 |
5506 | 5558 | 25 | |
5506 | 5558 | 25 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 180 Mscf | 0 | |||
H2O | 0 | 2100 Bbl | 80000 | 180M SCF NITROGEN ASSIST | ||
ACID | 0 | 500 Gal | 0 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-610089758 | 2004-2-19 0:00: | PW | No Violations | 0.50 |
-660858897 | 2007-4-2 0:00:0 | PW | No Violations | |
0000007829 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 9/18/92 INSPECTOR BRETT FARNSWORTH DATE 09/1819/92 DATA FROM OLD VAX INFO | |
0610089758 | 2004-02-19 | Production Wells | No Violations | The tank battery consists of 1-50 bbl storage tank, 1-separator and no dike. Also a wooden fence around it. |
0660858897 | 2007-04-02 | Production Wells | No Violations | This inspection was due to the Boardman Township Fire Departments request. The tank battery was GPSd. ID sign was posted on the tank battery. A cedar wood fenced surrounded the battery and the fence was locked. The dikes needed to be increased. There were no violations at this time. |
1077714124 | 2012-02-17 | UrbanProduction Wells | No Violations | I conducted a status check on this site and found that the well was equipped with a plunger lift system and it was fenced with board on board. The tank battery consists of one 50 barrel stock tank, one separator, and a meter run. There was no brine storage tank present. The tank battery was fenced with board on board and proper identification was posted. I found no leaks or spills at the tank battery or well head. No violations at this time. |
7829 | PL | No Violations |
For data sources see[9]