Well ID: 34-099-22695 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.02,"lon":-80.69,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Boardman Township | |
Operator Name: EVERFLOW EASTERN PARTNERS LP | |
Well Pad ID: | |
Farm/Lease Name: SAVON UNIT | |
License Status: Producing | |
License Date: 1996-06-07 | |
Spud Date: 1996-06-11 | |
Spud Drilling Contractor: CUBBY DRLG | |
Final Drill Date: 1996-06-21 | |
Well Total Depth: 5982.00 ft | |
Configuration: Directional | |
Latitude: 41.020000 | |
Longitude: -80.690000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1996-06-07 | 84 EVERFLOW EASTERN PTNS L P GeoDate 6/7/96 |
Oil and Gas | 1996-06-07 | Issued Date 6/7/96 Expired Date 6/7/97 Acres 0045000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05982 Proposed Drill Depth 05982 |
Original Spud | 1996-06-11 | CHG TGT/ XY/ELEV 1-18-97 |
Completed | 1996-06-21 | CHG TGT/ XY/ELEV 1-18-97 |
Reached Total Depth | 1996-06-21 | CHG TGT/ XY/ELEV 1-18-97 |
Completion Report Received | 1996-08-21 | CHG TGT/ XY/ELEV 1-18-97 |
Construction Permit Expires | 1997-06-07 | CHG TGT/ XY/ELEV 1-18-97 |
Record Last Modified | 2017-02-15 | CHG TGT/ XY/ELEV 1-18-97 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5708 | 5856 | 0 |
5708 | 5856 | 0 | |
2006-09-11 | 5722 | 5854 | 86 |
5722 | 5854 | 86 | |
5708 | 5856 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 117290 Gal | 100000 | FRAC W/117,290 GAL WATER AND 100M# |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1147797296 | 2018-4-17 0:00: | PW | No Violations | 0.80 |
-240134397 | 2007-5-3 0:00:0 | PW | No Violations | |
0240134397 | 2007-05-03 | Production Wells | No Violations | This inspection was due to the Boardman Township Fire Departments request. Well and tank battery were GPSd. ID signs posted. Wooden fence around well and tank battery. There were no violations at this time. |
0512987929 | 2005-04-28 | Production Wells | No Violations | The tank battery is shared with permit 2734 and consists of 1-100 bbl storage tank, 2-separators a dike and a fence. |
1147797296 | 2018-04-17 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check on well #2-2695. RBDMS indicated reported production was current. Access to the well and tank battery was stable through a commercial parking lot. The well head was enclosed by a locked wooden privacy fence that contained correct identification. The 8.625 well head was plumbed above grade and was closed to atmosphere. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. No leaks were observed. A domestic supply connection was present. The tank battery was shared with 2-2734 and 2-3066. The production equipment was positioned inside of a stable earthen dike that was free of fluid. A wooden privacy fence that contained correct identification for all wells produced into the battery was posted on the fence. Equipment on location consisted of three (3) horizontal separators, one (1) 50 bbl steel production tank and one (1) 50 bbl poly brine tank. The separator for well #2-2695 remained in good repair and contained a current 7 day production chart. The steel production tank remained in good repair. Valves were closed, locked and plugged. The poly tank remained in good repair. Valves were closed and plugged. No violations were observed during this inspection. |
512987929 | 2005-4-28 0:00: | PW | No Violations | 0.50 |
iANGE00056 | 1997-11-03 | Preliminary Restoration | No Violations | |
iANGE000566 | 1997-11-3 0:00: | PL | No Violations |