X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-099-22951

Well Details

Well ID: 34-099-22951
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Boardman Township
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: LEV
License Status: Producing
License Date: 2003-12-01
Spud Date: 2003-12-11
Spud Drilling Contractor: LANDOGS DRILLING
Final Drill Date: 2003-12-22
Well Total Depth: 6152.00 ft
Configuration: Directional
Latitude: 41.040000
Longitude: -80.650000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-07-24 2456 OHIO VALLEY ENERGY SYSTEM CORP Proposed Formation CLINTON Issued Date 7/24/2003 Expired Date 7/23/2004 6:00:00 AM
APP 2003-12-01 Proposed Formations:CLINTON, Issued Date:12/1/2003, Expired Date:11/30/2004 6:00:00 AM, Drilling unit acres:45.16, Proposed Well Type:OG, Proposed Well Class:POOL
Inspector Comments Cement Job 2003-12-11 Lost circulation problems with the conductor. Cemented the conductor from the top with 80 sacks of cemernt. Cement stayed up. Circulation was not established until displacement of the cement. Cement did circulate. Seven barrels of returns.Cement Ticket Notes Inspector Reporting PATRICK JONNIE
Original Spud 2003-12-11 RBDMS Rec
Completed 2003-12-22 RBDMS Rec
Reached Total Depth 2003-12-22 RBDMS Rec
Completion Report Received 2004-01-09 RBDMS Rec
Correction to Well 2004-01-23 CORRECTION TO TARGET INFORMATION: FOOTAGE = 5,232'NL & 9,612'EL OF TWP. (IN LOT 21,DIVISION 4);X=2,509,989 Y= 508, 002 (SOURCE OF LOCATION: "AS DRILLED SURVEY").
Construction Permit Expires 2004-11-30 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-03-12 5802 5882 0
5802 5882 0
5802 5882 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 8 2935 Bbl 80000 1000 GALLONS IC ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 OHIO VALLEY ENERGY SYSTEMS COR 38979.00 20.00 262
2005 OHIO VALLEY ENERGY SYSTEMS COR 32794.00 20.00 364
2006 OHIO VALLEY ENERGY SYSTEMS COR 21891.00 38.00 364
2007 OHIO VALLEY ENERGY SYSTEMS COR 17078.00 0.00 0
2008 OHIO VALLEY ENERGY SYSTEMS COR 14059.00 20.00 365
2009 OHIO VALLEY ENERGY SYSTEMS COR 11156.00 8.00 365
2010 OHIO VALLEY ENERGY SYSTEMS COR 10778.00 0.00 365
2011 OHIO VALLEY ENERGY SYSTEMS COR 11477.00 18.00 365
2012 OHIO VALLEY ENERGY SYSTEMS COR 10017.00 13.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 10565.00 12.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 9180.00 0.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 8870.00 0.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 10076.00 40.00 365
2017 OHIO VALLEY ENERGY SYSTEMS COR 10579.00 0.00 365
2018 OHIO VALLEY ENERGY SYSTEMS COR 7251.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 OHIO VALLEY ENERGY SYSTEMS COR Brine 219 262
2005 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 364
2006 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 364
2007 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 0
2008 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 9 365
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 41 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 6 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 79 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 36 365
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1159480593 2003-12-22 0:00 DD No Violations 0.50
-1975582187 2004-10-7 0:00: PW No Violations 0.50
-335339456 2012-9-11 0:00: PW No Violations 1.00
-812630438 2004-7-13 0:00: PW No Violations 0.50
0335339456 2012-09-11 Production Wells No Violations On 9/11/2012, I performed a status check on the above well site. The tank battery is equipped with one horizontal separator. This well shares the same tank as the 3409922811, Youngtowns Christian School #1. This is a plunger lift with 1.5 tubing. There is 0 psi on the 8.625. Identification signs are posted. No violation were noted at this time.
0683334962 2003-12-12 Drill / Deepen / Reopen No Violations At 101 with 87 of conductor in the hole waiting on one more joint since they lost circulation.
0812630438 2004-07-13 Production Wells Violations Noted The tank battery consists of 1-100 bbl storage tank, 3-separators a dike and a fence.
0929558731 2012-02-02 UrbanProduction Wells No Violations I conducted a status check on this site and found that the well head was fenced with chain link and it is equipped with a plunger lift system. The tank battery consists of one 100 barrel stock tank and three separators. There was no brine storage tank present. The thief hatch was closed and there was a bull plug installed in the draw valve. The tank battery was fenced with chain link and the dike was free of vegetation and debris. The tank battery is shared with permits 2541 and 2811. Proper identification was posted, and I found no leaks or spills at the well head or the tank battery. I took new GPS coordinates of the well head and tank battery. No violations at this time.
1009601252 2004-10-07 Preliminary Restoration No Violations Meets requirements.
1159480593 2003-12-22 Drill / Deepen / Reopen No Violations Drilling continues. Presently at 5466. Anticipate twelve more hours of driling to completion.
1194985103 2007-11-14 Production Wells No Violations I preformed a random field inspection. GPSd the well and the tank battery. ID signs were posted. The tank battery was in very good shape. Nice and clean. There were no violations at this time.
1640117643 2007-11-14 Preliminary Restoration No Violations I preformed a preliminary restoration status check. The drilling equipment is gone. The drilling pits have been closed. The debris has been removed. Vegetation is growing. ID signs were posted. This well has PASSED PRELIMINARY RESTORATION.
1825256291 2004-01-20 Preliminary Restoration No Violations The drilling pits are closed. The tank battery is shared with permits:2541 and 2811 and consists of: 2-100 bbl storage tanks, 3-separators, 1-50 bbl salt water tank and a dike.
1975582187 2004-10-07 Production Wells No Violations The contamination has been removed. Recommend case be resolved.
683334962 2003-12-12 0:00 DD No Violations 1.00
929558731 2012-2-2 0:00:0 UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0812630438 US-OH-129249 2004-07-15 Well operation causing pollution and contamination

For data sources see[9]

References