X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-099-22986

Well Details

Well ID: 34-099-22986
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Boardman Township
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: WBA UNIT
License Status: Producing
License Date: 2005-07-15
Spud Date: 2005-08-11
Spud Drilling Contractor: LANDOGS DRILLING
Final Drill Date: 2005-08-19
Well Total Depth: 6098.00 ft
Configuration: Directional
Latitude: 41.020000
Longitude: -80.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-07-15 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:7/15/2005, Expired Date:7/15/2006 6:00:00 AM, Drilling unit acres:49.45, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2005-07-15 TARGET INFORMATION: 280'SL & 240'WL OF LOT 1-3-5, DIVISION 2 (S); X= 2,504,425; Y= 500,715; ELEV= 1055'.
Original Spud 2005-08-11 RBDMS Rec
Completed 2005-08-19 RBDMS Rec
Reached Total Depth 2005-08-19 RBDMS Rec
Completion Report Received 2005-10-06 RBDMS Rec
Correction to Well 2005-10-21 UNIT SIZE INCREASED TO 50.03 ACRES. CORRECTION TO TARGET LOCATION: 695'SL & 220'WL OF LOTS 1-3-5, 2ND DIVISION; X= 2,504,470; Y= 500,695.
Construction Permit Expires 2006-07-15 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2005-12-06 5848 5963 0
5848 5963 0
5848 5963 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 2766 Bbl 80000 1000 GALLONS IC ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 OHIO VALLEY ENERGY SYSTEMS COR 22281.00 454.00 345
2007 OHIO VALLEY ENERGY SYSTEMS COR 20788.00 208.00 364
2008 OHIO VALLEY ENERGY SYSTEMS COR 24700.00 135.00 365
2009 OHIO VALLEY ENERGY SYSTEMS COR 20144.00 50.00 365
2010 OHIO VALLEY ENERGY SYSTEMS COR 18775.00 0.00 365
2011 OHIO VALLEY ENERGY SYSTEMS COR 15839.00 69.00 365
2012 OHIO VALLEY ENERGY SYSTEMS COR 10960.00 0.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 8417.00 0.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 8397.00 0.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 8454.00 0.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 7838.00 0.00 365
2017 OHIO VALLEY ENERGY SYSTEMS COR 6971.00 0.00 365
2018 OHIO VALLEY ENERGY SYSTEMS COR 6531.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 345
2007 OHIO VALLEY ENERGY SYSTEMS COR Brine 230 364
2008 OHIO VALLEY ENERGY SYSTEMS COR Brine 20 365
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 73 365
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 68 365
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 42 365
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 17 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 21 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-228820011 2005-8-13 0:00: DD No Violations 3.00
-946922532 2007-4-10 0:00: PL No Violations
-947167378 2005-8-25 0:00: PL No Violations 0.50
0228820011 2005-08-13 Drill / Deepen / Reopen No Violations Arrived for a B.O.P. Test. Tested at 550psi. After 15 minutes 390 psi. Tested at 700 psi. After fifteen minutes 690 psi.
0247429643 2005-08-12 Drill / Deepen / Reopen No Violations Drilling at 295. Expect surface this evening.
0946922532 2007-04-10 Preliminary Restoration No Violations GPSd the wellhead and tank battery. The drilling pits were filled in. Vegetation was growing on the location. No erosion was visible. No drilling equipment on location. This well and tank battery has passed the preliminary restoration.
0947167378 2005-08-25 Preliminary Restoration No Violations Met with Tom Tugend to check the progress of pit closures. Emptying the pits at this time.
1124107172 2005-08-12 Drill / Deepen / Reopen No Violations Arrived on site for the surface job. Ran pipe and cemented in. Cement stayed up.
1128346839 2005-09-29 Preliminary Restoration No Violations The pits are closed. Building the tank battery. Partial compliance.
1524844523 2018-04-25 Production Wells No Violations The purpose of my inspection was to conduct a status check inspection on well #2-2986. Inspector John Fleming was present during the inspection. RBDMS indicated reported production was current. Access to the well and tank battery remained stable and drivable. The well head was enclosed by a locked chain-link fence enclosure with green plastic privacy shielding. Correct identification was present on the fence. The 8.625 well head was at grade. The production annulus was plumbed into the sales line. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. No leaks were observed. The tank battery was shared with #2374, 2823 and 2979. A stable earthen dike that was free of fluid was present around the production equipment. A locked chain-link fence enclosure with green plastic privacy shielding that contained correct identification for all wells produced into the battery was present on the fence. Equipment within the dike consisted of four (4) horizontal separators, one (1) 140 bbl production tank, one (1) 50 bbl brine tank and one (1) 50 bbl production tank. The separator for 2986 remained in good repair and contained a current production chart. Production was shut in at the time of inspection. The production tank exhibited signs of corrosion and production fluid was staining the body of the tank. The fluid was not live or mobile. The tank was vented into a charcoal filter. The hatch lid was secured. A lightening arrestor was in place. Valves were closed and plugged. The brine tank remained in good repair. I will contact the operator to discuss the status of the production tank.
247429643 2005-8-12 0:00: DD No Violations 1.50

For data sources see[9]

References