34-099-22994

Well Details

Well ID: 34-099-22994
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: AM-TEK OIL INC
Well Pad ID:
Farm/Lease Name: TOD HOMESTEAD CEMETERY
License Status: Producing
License Date: 2005-08-31
Spud Date: 2006-03-01
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-03-08
Well Total Depth: 5349.00 ft
Configuration: Vertical
Latitude: 41.130000
Longitude: -80.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-08-31 Proposed Formations:ORISKANY/CLINTON, Issued Date:8/31/2005, Expired Date:8/31/2006 6:00:00 AM, Drilling unit acres:161.91, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2006-03-01 RBDMS Rec
Completed 2006-03-08 RBDMS Rec
Reached Total Depth 2006-03-08 RBDMS Rec
Completion Report Received 2006-05-01 RBDMS Rec
Construction Permit Expires 2006-08-31 RBDMS Rec
Record Last Modified 2015-09-24 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-07-13 3543 3553 20
2006-07-13 5126 5244 79
3543 3553 20
5126 5244 79
3543 3553 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 78000 Gal 0 500 GALLONS HCL ACID
ACID 15 1000 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 DUCK CREEK ENERGY INC 2020.00 83.00 210
2007 DUCK CREEK ENERGY INC 8755.00 356.00 365
2008 DUCK CREEK ENERGY INC 8306.00 212.00 365
2009 DUCK CREEK ENERGY INC 6414.00 152.00 365
2010 DUCK CREEK ENERGY INC 8976.00 126.00 365
2011 DUCK CREEK ENERGY INC 9425.00 164.00 365
2012 DUCK CREEK ENERGY INC 8090.00 163.00 366
2013 DUCK CREEK ENERGY INC 5562.00 29.00 365
2014 DUCK CREEK ENERGY INC 3736.00 86.00 365
2015 DUCK CREEK ENERGY INC 3436.00 29.00 365
2016 DUCK CREEK ENERGY INC 4604.00 122.00 365
2017 DUCK CREEK ENERGY INC 4018.00 153.00 365
2018 DUCK CREEK ENERGY INC 4615.00 76.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 DUCK CREEK ENERGY INC Brine 389 210
2007 DUCK CREEK ENERGY INC Brine 360 365
2008 DUCK CREEK ENERGY INC Brine 138 365
2009 DUCK CREEK ENERGY INC Brine 170 365
2010 DUCK CREEK ENERGY INC Brine 155 365
2011 DUCK CREEK ENERGY INC Brine 124 365
2012 DUCK CREEK ENERGY INC Brine 121 366
2013 DUCK CREEK ENERGY INC Brine 45 365
2014 DUCK CREEK ENERGY INC Brine 19 365
2015 DUCK CREEK ENERGY INC Brine 16 365
2016 DUCK CREEK ENERGY INC Brine 54 365
2017 DUCK CREEK ENERGY INC Brine 52 365
2018 DUCK CREEK ENERGY INC Brine 87 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1191823445 2006-3-7 0:00:0 PL No Violations 1.00
0106513745 2018-12-26 Production Wells No Violations I performed status check inspection on the above well. Access to the well and tank battery remained drivable and stable through the Tod Cemetery. The well was located within a locked chain-link enclosure that contained correct identification. The 8.625 well head was below grade. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. No leaks were observed. A stable earthen dike that was free of fluid was present around the production equipment. A locked chain-link fence enclosure was present on top of the dike. Privacy screening on the fence was deteriorated. Correct identification was present on the fence. Equipment on location consisted of one (1) vertical separators and one (1) 140 bbl production tanks. The separators remained in good repair. No production charts were present. The production tanks remained in good repair. Valves were closed and plugged. A charcoal filter was present. Hatch lids were closed. No violations were observed during this inspection.
0549186213 2007-04-05 Preliminary Restoration No Violations There was good vegetation growth around the location and on the location. The drilling pits were filled in. No drilling equipment was on location. No erosion on location or lease road were found. All the debris was removed. This well and tank battery has passed preliminary restoration.
106513745 2018-12-26 0:00 PW No Violations 1.00
1191823445 2006-03-07 Preliminary Restoration No Violations Arrived on site to chec the status of the drilling pits. The pits are open and enclosed inside a fence. No problems at this time.
1466952305 2006-05-08 Preliminary Restoration No Violations The tank battery is shared with Permit: 2997 and consists of 2-100 bbl storage tanks, 2-separators a fence and a dike. The well is not in production as yet. The pits are closed this date. Partial compliance for preliminary restoration.
1531847737 2018-06-26 Production Wells No Violations The purpose of my inspection was to conduct a status check inspection on well #2-2994. Inspector John Fleming was present during the inspection. RBDMS indicated reported production was current. Access to the well and tank battery remained drivable and stable through the Tod Cemetery. The well was located within a locked chain-link enclosure that contained correct identification. The 8.625 well head was below grade. The 4.5 production casing was equipped with a casing gas powered pump jack. Production valves were in the open position. No leaks were observed. Staining consistent with a legacy operation was present on the stuffing box and well head. The staining was not live or fresh. The Pittman arm bearing on the pumping unit appeared to be off center. We returned a short time later when the logic box started the unit and witnessed the unit operating. At the time of operation, the bearing was performing as designed. No other issues were observed. The tank battery was shared with #2-2995. A stable earthen dike that was free of fluid was present around the production equipment. A locked chain-link fence enclosure was present on top of the dike. Privacy screening on the fence was deteriorated. Correct identification was present on the fence. Equipment on location consisted of two (2) vertical separators and two (2) 140 bbl production tanks. The separators remained in good repair. No production charts were present. The production tanks remained in good repair. Valves were closed and plugged. Production fluid stained an area less than 1 square foot under the tank load out valves. The staining was not fresh or live. A charcoal filter was present. Hatch lids were closed. No violations were observed during this inspection.
549186213 2007-4-5 0:00:0 PL No Violations

For data sources see[9]

References