X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-099-23066

Well Details

Well ID: 34-099-23066
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Boardman Township
Operator Name: EVERFLOW EASTERN PARTNERS LP
Well Pad ID:
Farm/Lease Name: SAVON UNIT WELL
License Status: Producing
License Date: 2007-12-03
Spud Date: 2008-01-04
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2008-01-11
Well Total Depth: 6014.00 ft
Configuration: Directional
Latitude: 41.020000
Longitude: -80.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-12-03 Proposed Formations:CLINTON, Issued Date:12/3/2007, Expired Date:12/2/2008 6:00:00 AM, Drilling unit acres:54.59, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-01-11
Completion Report Received 2008-02-19
Correction to Well 2008-03-14 CHANGE IN TARGET INFORMATION: NEW FOOTAGE= 1500'SL & 1085'WL OF LOT 22, DIVISION 3; X= 2,499,895; Y= 501,365; ELEV.= 1035'.
Change of Owner 2008-03-17 Operator changed from 84, EVERFLOW EASTERN PTNS L P to 2456, OHIO VALLEY ENERGY SYSTEM CORP
Construction Permit Expires 2008-12-02
Change of Owner 2011-05-24 Operator changed from 2456, OHIO VALLEY ENERGY SYSTEM CORP to 84, EVERFLOW EASTERN PTNS L P
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-05-23 5644 5714 126
5644 5714 126
5644 5714 126

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 8 2857 Bbl 100000 1000 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 OHIO VALLEY ENERGY SYSTEMS COR 10439.00 0.00 177
2009 OHIO VALLEY ENERGY SYSTEMS COR 25231.00 0.00 365
2010 OHIO VALLEY ENERGY SYSTEMS COR 21199.00 0.00 365
2011 EVERFLOW EASTERN PARTNERS LP 19841.00 0.00 365
2012 EVERFLOW EASTERN PARTNERS LP 13262.00 0.00 306
2013 EVERFLOW EASTERN PARTNERS LP 16658.00 0.00 365
2014 EVERFLOW EASTERN PARTNERS LP 13604.00 0.00 365
2015 EVERFLOW EASTERN PARTNERS LP 12064.00 0.00 365
2016 EVERFLOW EASTERN PARTNERS LP 9333.00 0.00 365
2017 EVERFLOW EASTERN PARTNERS LP 8988.00 0.00 365
2018 EVERFLOW EASTERN PARTNERS LP 7424.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 OHIO VALLEY ENERGY SYSTEMS COR Brine 15 177
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 57 365
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 40 365
2011 EVERFLOW EASTERN PARTNERS LP Brine 54 365
2012 EVERFLOW EASTERN PARTNERS LP Brine 0 306
2013 EVERFLOW EASTERN PARTNERS LP Brine 9 365
2014 EVERFLOW EASTERN PARTNERS LP Brine 94 365
2015 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2016 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2017 EVERFLOW EASTERN PARTNERS LP Brine 7 365
2018 EVERFLOW EASTERN PARTNERS LP Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-140073221 2008-1-7 0:00:0 DD No Violations
-1865208127 2008-8-5 0:00:0 PL No Violations
-224065328 2008-6-9 0:00:0 PL No Violations
0140073221 2008-01-07 Drill / Deepen / Reopen No Violations I performed a rig inspection. The pit liners were in good shape. Drilling depth was 3004. Location in good shape. There were no violations at this time.
0224065328 2008-06-09 Preliminary Restoration No Violations I performed a preliminary restoration status check. The drilling pits were closed and the drilling equipment was gone. The debris has been hauled away. The fence is around the wellhead and the fence is around the tank battery. There is still a top soil pile on the location. This well has not passed preliminary restoration.
0434942196 2008-08-26 Preliminary Restoration No Violations I performed a preliminary restoration status check. I GPSd both the well and the tank battery. The ID signs were posted. The drilling rig is gone and the debris was removed. The board on board fences are around the tank battery and the wellhead. The pits are closed. There is vegetation growing on the location. This well has PASSED PRELIMINARY RESTORATION.
1004618447 2008-03-04 Preliminary Restoration No Violations I performed a preliminary restoration status check. The drilling pits are closed. The drilling equipment is gone. The debris has been removed. The dirt piles are still there. The fence has been placed around the wellhead and the tank battery. This location does not pass preliminary restoration.
1199711154 2008-01-05 Drill / Deepen / Reopen No Violations I performed a rig inspection. The pit liners were in good shape. The pits had a fence around them. The location was in good shape. There were no violations at this time.
1199965438 2008-01-09 Drill / Deepen / Reopen No Violations I performed a rig inspection. The drilling pit liners were in good shape. They had a tarp over the blow line to keep down on noise. Drilling depth was 4337. There were no violations at this time.
1200316589 2008-01-11 Drill / Deepen / Reopen No Violations I received a phone call from Mrs. Ralph Sinistro from 7115 Pinewood Dr. in Boardman. Phone number is 330-758-2712. She was very concerned about the drilling rig ruining her water well. I met with Mr. And Mrs. Sinistro. I explained to them about the drilling process. Everflow Eastern agreed to have someone test her water well next week. They were satisfied. Case resolved.
1200426966 2008-01-15 Preliminary Restoration No Violations I performed a preliminary status check. The drilling rig and equipment is gone. The drilling pit liners in good shape. The fluid level is 8 from the top. There is a fence around the drilling pits. The debris is still on location. This well does not pass preliminary restoration.
1203770238 2018-04-17 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-3066. RBDMS indicated reported production was current. Access to the well and tank battery was stable through a residential yard. The well head was enclosed by a locked wooden privacy fence that contained correct identification. The 8.625 well head was plumbed above grade and was closed to atmosphere. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. No leaks were observed. A domestic supply connection was present. The tank battery was shared with 2-2695 and 2-2734. The production equipment was positioned inside of a stable earthen dike that was free of fluid. A wooden privacy fence that contained correct identification for all wells produced into the battery was posted on the fence. Equipment on location consisted of three (3) horizontal separators, one (1) 50 bbl steel production tank and one (1) 50 bbl poly brine tank. The separator for well #2-3066 remained in good repair and contained a current 7 day production chart. The steel production tank remained in good repair. Valves were closed, locked and plugged. The poly tank remained in good repair. Valves were closed and plugged. No violations were observed during this inspection.
1859200511 2008-02-12 Preliminary Restoration No Violations I witnessed the solidification of the drilling pits. The trackhoe broke down halfway thru job. Will continue tomorrow. The well and the tank battery were GPSd. I found no violations at this time.
1865208127 2008-08-05 Preliminary Restoration No Violations I performed a preliminary restoration status check. I GPSd both the tank battery and the well. The debris is gone as well as the rig. The pits are closed. The top soil was spread out on the location. But the grass seed or straw have not been spread on the location. This well has not passed preliminary restoration.
1886532171 2008-01-05 Drill / Deepen / Reopen No Violations I witnessed the running and the cementing of the 8 5/8 casing. I found no violations at this time.
434942196 2008-8-26 0:00: PL No Violations

For data sources see[9]

References