34-099-23099

Well Details

Well ID: 34-099-23099
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Canfield Township
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: ST MICHAELS
License Status: Producing
License Date: 2008-08-15
Spud Date: 2009-02-09
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2009-02-16
Well Total Depth: 5959.00 ft
Configuration: Directional
Latitude: 41.030000
Longitude: -80.760000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-08-15 Proposed Formations:BEREA THRU CLINTON, Issued Date:8/15/2008, Expired Date:8/15/2009 6:00:00 AM, Drilling unit acres:54.4, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2009-01-09 UNIT SIZE INCREASED TO 55.21 ACRES.
Reached Total Depth 2009-02-16
Correction to Well 2009-04-10 CORRECTION TO TARGET INFORMATION, DUE TO SUBMITTAL OF AS DRILLED SURVEY: NEW FOOTAGE:100'NL & 2070'EL OF LOT 2, 2ND DIVISION; NEW X= 2,477,725 AND NEW Y= 502,140.
Construction Permit Expires 2009-08-15
Completion Report Received 2009-09-16
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-12-21 5647 5711 92
5647 5711 92
5647 5711 92

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 8 2619 Bbl 67300

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 OHIO VALLEY ENERGY SYSTEMS COR 32806.00 66.00 267
2011 OHIO VALLEY ENERGY SYSTEMS COR 34034.00 0.00 365
2012 OHIO VALLEY ENERGY SYSTEMS COR 29632.00 49.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 23573.00 0.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 18082.00 0.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 15655.00 0.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 15530.00 0.00 365
2017 OHIO VALLEY ENERGY SYSTEMS COR 14086.00 0.00 365
2018 OHIO VALLEY ENERGY SYSTEMS COR 9991.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 216 267
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 65 365
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 60 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 62 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1517539176 2009-2-10 0:00: DD No Violations
-1949189255 2010-7-15 0:00: PW No Violations
-1977651473 2009-7-23 0:00: PL No Violations
0410396971 2015-03-31 Production Wells No Violations I performed a status check on the above location. The tank battery is equipped with (1) one 100 barrel tank and (1) 35 barrel tank one (1) horizontal separator. The well is equipped 1.5 plunge lift. No noted violations at this time. ID signs are posted
1232970809 2009-01-15 Not Drilled No Violations I met with Dale Nething from Ohio Valley Energy. Dale wanted to change the direction of the rig from north/south to east west. I approved of the change. There were no violations at this time.
1234292819 2009-02-10 Drill / Deepen / Reopen No Violations I performed a rig inspection. I GPSd the well. The pits and pit liners were in good shape. The silt fence and orange fence were up. The ID sign was posted at the church entrance. There were no violations at this time.
1234466682 2009-02-11 Drill / Deepen / Reopen No Violations I performed a rig inspection. The pits and pit liners were in good shape. The location was in good shape. The drilling depth was 1707. The rig was making a trip. There were no violations at this time.
1234524949 2009-02-12 Drill / Deepen / Reopen No Violations I performed a rig inspection. The pit liners and the location were in good shape. The drilling depth was 2911. There were no violations at this time.
1234985439 2009-02-17 Drill / Deepen / Reopen No Violations I performed a rig inspection. The pits and pit liners were in good shape as will as the location. The rig was running the 4 1/2 casing. There were no violations at this time.
1235506534 2009-02-23 Preliminary Restoration No Violations I performed a preliminary restoration status check. The fence was around the pits. The drilling rig was gone. The debris was still on the location. The pit liners were in good shape. The fluid level in the pits were done 3 feet. This well has not passed preliminary restoration.
1235679451 2009-02-26 Preliminary Restoration No Violations I performed a preliminary restoration status check. The drilling rig is gone but the debris is still there. The pits were solidified and closed. This well has not passed preliminary restoration.
1243606899 2009-05-29 Preliminary Restoration No Violations The board fences are up around the tank battery and the wellhead. The ID sign is posted. The top soil is spread on the location. No seed is down yet. This well does not pass preliminary restoration
1246473417 2009-07-01 Preliminary Restoration No Violations Vegetation is starting to grow on the drilling location. The ID sign is posted. This well does not pass preliminary restoration.
1436156599 2012-02-21 UrbanProduction Wells No Violations On 2/21/2012, DNR Inspector Richard Skidmore completed an urban production well inspection status check for DNR Inspector Chris Grimm. The off-set board-on-board fencing at the well head and tank battery were in good condition. Proper identification signs were posted on both the well head and tank battery fences. The lease road, tank battery, and well head are in compliance with 1501:9-9-05. Inspection passed.
1517539176 2009-02-10 Drill / Deepen / Reopen No Violations I witnessed the cementing of the 8 5/8 casing. There were no violations at this time.
1658354117 2009-07-07 Preliminary Restoration No Violations Vegetation was growing. There was some erosion on the south side of the fenced in well. I called Ted Hill from Ohio Valley, 330-710-0100. I told Ted that there needed to be some erosion control on the south side. Rain had washed the seed and the straw away. Ted said he would repair the top soil and get seed, straw on it. This well has not passed preliminary restoration.
1949189255 2010-07-15 Production Wells No Violations I performed a random field inspection. I GPSd both the tank battery and the wellhead. I continued to walk around both the wellhead and the tank battery. This inspection satisfies 1501:9-9-05. There were no violations at this time.
1977651473 2009-07-23 Preliminary Restoration No Violations Vegetation is growing. The ID signs are posted. The board on board fences are up. This well PASSES PRELIMINARY RESTORATION.
410396971 2015-3-31 0:00: PW No Violations 1.00

For data sources see[9]