34-099-23119

Well Details

Well ID: 34-099-23119
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BOCOR HOLDINGS, LLC
Well Pad ID:
Farm/Lease Name: LANSDOWNE
License Status: Producing
License Date: 2009-10-13
Spud Date: 2009-11-11
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 2009-11-16
Well Total Depth: 5413.00 ft
Configuration: Vertical
Latitude: 41.120000
Longitude: -80.610000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-10-13 Proposed Formations:CLINTON/MEDINA, Issued Date:10/13/2009, Expired Date:10/13/2010 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-11-16
Completion Report Received 2010-02-11
Construction Permit Expires 2010-10-13
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-05-06 5158 5255 60
2010-05-06 5306 5309 7
5306 5309 7
5158 5255 60
5158 5255 60

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 80003 Gal 60000 FRACED INTERVAL INCLUDES THE MEDINA

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
0 0 0
2012 BOCOR HOLDINGS, LLC 6286.00 23.00 366
2013 BOCOR HOLDINGS, LLC 4586.00 22.00 365
2014 BOCOR HOLDINGS, LLC 4434.00 0.00 365
2015 BOCOR HOLDINGS, LLC 2970.00 0.00 366
2016 BOCOR HOLDINGS, LLC 2012.00 12.00 365
2017 BOCOR HOLDINGS, LLC 1997.00 0.00 365
2018 BOCOR HOLDINGS, LLC 1798.00 9.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 BOCOR HOLDINGS, LLC Brine 35 366
2013 BOCOR HOLDINGS, LLC Brine 0 365
2014 BOCOR HOLDINGS, LLC Brine 0 365
2015 BOCOR HOLDINGS, LLC Brine 0 366
2016 BOCOR HOLDINGS, LLC Brine 0 365
2017 BOCOR HOLDINGS, LLC Brine 0 365
2018 BOCOR HOLDINGS, LLC Brine 30 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1150825322 2009-11-13 0:00 DD No Violations
-51423985 2009-11-23 0:00 PL No Violations
-662613545 2009-11-17 0:00 DD No Violations
0051423985 2009-11-23 Preliminary Restoration No Violations The drilling rig is gone and the debris has been removed. The workover rig is on the location. The drilling pit fluid level is down 4 feet. This well has not passed preliminary restoration.
0662613545 2009-11-17 Drill / Deepen / Reopen No Violations I performed a rig inspection. The drilling depth was 5415TD. There were no violations at this time.
0830854967 2010-05-25 Preliminary Restoration No Violations The ID signs were posted. This well has PASSED PRELIMINARY RESTORATION.
1150825322 2009-11-13 Drill / Deepen / Reopen No Violations I performed a rig inspection on G & H rig #91. The drilling depth was 2138. There were no violations at this time.
1258035886 2009-11-12 Drill / Deepen / Reopen No Violations I witnessed the cementing of the 8 5/8 casing on G & H drilling rig #91. There were no violations at this time.
1258484251 2009-11-16 Drill / Deepen / Reopen No Violations I performed a rig inspection. The drilling depth was 5104 for G & H rig #91. On air. There were no violations at this time.
1259784613 2009-12-02 Preliminary Restoration No Violations The drilling pits were closed and the top soil roughed in. The debris is gone. This well has not passed preliminary restoration.
1481659175 2018-07-25 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-3119. A review of RBDMS indicated reported production was current. Access to the well and tank battery was through a locked gate that marked the entrance to a private airfield. The well was located within a chain-link enclosure. Correct identification was present. Mature vegetation was present adjacent within the enclosure. The 8.625 well head was below grade. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. No leaks were observed. The tank battery was shared with #2-3118. A locked chain-link enclosure was present on top a stable earthen dike. The dike remained free of production fluid. Equipment on location consisted of one (1) horizontal separator, one (1) steel production tank and one (1) 1400 gallon poly brine tank. The separator remained in good repair and contained a current 31 day chart. The production tank remained in good repair and contained correct identification. Valves were closed. The hatch lid was closed. The poly brine tank remained in good repair. The inlet valve was closed. At the time of my inspection the drain line valve was missing a plug and dripping production fluid onto the ground. The fluid was not pooling or mobile. While on location I called and notified lease operator Tom Huffman of the missing plug and leak. Mr. Huffman stated he would make necessary repairs to stop the leak and install the plug as soon as possible. I will schedule a follow-up inspection to document the status of repairs.
1942553751 2009-11-12 Drill / Deepen / Reopen No Violations I performed a rig inspection on G & H drilling rig #91. There were no violations at this time.
1995299328 2010-03-17 Preliminary Restoration No Violations There are still three piles of top soil around the drilling location. The ID sign is posted. This well has not passed preliminary restoration.
830854967 2010-5-25 0:00: PL No Violations