If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-099-23188 | ![]() Sorry, we have no imagery here. Sorry, we have no imagery here. ![]() |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Jackson Township | |
Operator Name: PIN OAK ENERGY PARTNERS LLC | |
Well Pad ID: US-OH-000701 | |
Farm/Lease Name: DAVIDSON | |
License Status: Producing | |
License Date: 2013-04-04 | |
Spud Date: 2013-04-05 | |
Spud Drilling Contractor: PATTERSON DRILLING | |
Final Drill Date: 2013-05-27 | |
Well Total Depth: 11634.00 ft | |
Configuration: Horizontal | |
Latitude: 41.110000 | |
Longitude: -80.890000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2013-04-04 | Proposed Formations:POINT PLEASANT, Issued Date:4/4/2013, Expired Date:4/4/2015 12:00:00 PM, Drilling unit acres:151.52, Proposed Well Type:OG, Proposed Well Class:EDPW |
APP | 2013-05-17 | 8966 HALCON OPERATING COMPANY INC Proposed Formation TRENTON Issued Date 5/17/2013 Expired Date 5/17/2015 12:00:00 PM |
Reached Total Depth | 2013-05-27 | |
Correction to Well | 2013-12-13 | CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGE AND COORDINATES) FROM AS DRILLED SURVEY PLAT. |
Construction Permit Expires | 2015-04-04 | |
Completion Report Received | 2016-04-14 | |
Change of Owner | 2017-09-12 | Operator changed from 8966, HALCON OPERATING COMPANY INC to 9722, PIN OAK ENERGY PARTNERS LLC |
Record Last Modified | 2017-10-23 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2014-08-08 | 6612 | 508 | |
6612 | 508 | ||
6612 | 508 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 06/15/2013 | 06/21/2013 | 6654 | 4,876,540.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FRW-200 | FTSI | Friction reducer | Acrylamide | 79-06-1 | 0.1 | 0.00001000 | 0 |
Copolymer of acrylamide and sodium acrylate | 25987-30-8 | 33 | 0.00316 | 0 | ||||
Ammonium Chloride | 12125-02-9 | 12 | 0.00115 | 0 | ||||
Water | 7732-18-5 | 48 | 0.0046 | 0 | ||||
Sorbitan Monooleate | 1338-43-8 | 3 | 0.00029 | 0 | ||||
Alkyloxypolyethyleneoxyethanol | 84133-50-6 | 1 | 0.0001 | 0 | ||||
Acrylamide P/W acrylic acid, ammonium salt | 26100-47-0 | 25 | 0.0024 | 0 | ||||
Alcohols (C10-C16), ethoxylated | 68002-97-1 | 4 | 0.00038 | 0 | ||||
Petroleum distillate hydrotreated light | 64742-47-8 | 26 | 0.00249 | 4621 | ||||
Alcohols (C12-C16), ethoxylated | 68551-12-2 | 4 | 0.00038 | 0 | ||||
Sorbitol Tetraoleate | 61723-83-9 | 2 | 0.00019 | 0 | ||||
Polyethylene glycol monooleate | 9004-96-0 | 3 | 0.00029 | 0 | ||||
Surfactant | Proprietary | 7 | 0.00067 | 0 | ||||
Ammonium Acrylate | 10604-69-0 | 0.5 | 0.00005000 | 0 | ||||
Proprietary Component | Proprietary | 1.5 | 0.00014 | 0 | ||||
Alcohols (C12-C14), ethoxylated | 68439-50-9 | 4 | 0.00038 | 0 | ||||
CI-150 | FTSI | Acid Corrosion Inhibitor | Isopropanol | 67-63-0 | 30 | 0.00122 | 1968 | |
Diethylene glycol | 111-46-6 | 1 | 0.00004000 | 0 | ||||
Fatty Acid Salt | Proprietary | 0.1 | 0 | 0 | ||||
Organic amine resin salt | Proprietary | 30 | 0.00122 | 0 | ||||
Alkylene Oxide Block Polymer | Proprietary | 10 | 0.00041 | 0 | ||||
Fatty Acid | Proprietary | 0.1 | 0 | 0 | ||||
Aromatic aldehyde | Proprietary | 10 | 0.00041 | 0 | ||||
Ethylene Glycol | 107-21-1 | 30 | 0.00122 | 0 | ||||
Dimethylformamide | 68-12-2 | 10 | 0.00041 | 0 | ||||
Water | 7732-18-5 | 5 | 0.0002 | 0 | ||||
Aliphatic alcohol | Proprietary | 0.1 | 0 | 0 | ||||
Quaternary ammonium compound | Proprietary | 10 | 0.00041 | 0 | ||||
30/50 Super LC | FTSI | Proppant | 30/50 Super LC | 14808-60-7 | 100 | 2.65637 | 1,280,570.0 | |
BXL-2 | FTSI | Borate crosslinker | Potassium hydroxide | 1310-58-3 | 12 | 0.01159 | 0 | |
Boric acid | 10043-35-3 | 15 | 0.01449 | 0 | ||||
Sodium metaborate | 10555-76-7 | 25 | 0.02415 | 46565 | ||||
Water | 7732-18-5 | 75 | 0.07244 | 0 | ||||
KCLS-2 | FTSI | KCl Substitute | Methanol | 67-56-1 | 2 | 0.00089 | 0 | |
3rd Party Proprietary | Not available. | 0 | 0 | 0 | ||||
Quaternary Ammonium Chloride | 70750-07-1 | 60 | 0.02668 | 21438 | ||||
Hydrochloric Acid (HCl) | FTSI | Acid | Hydrogen Chloride | 7647-01-0 | 7.5 | 0.11563 | 743200 | |
Water | 7732-18-5 | 92.5 | 1.42604 | 0 | ||||
FE-100L | FTSI | Iron control | Citric acid | 77-92-9 | 55 | 0.00179 | 1571 | |
Water | 7732-18-5 | 60 | 0.00196 | 0 | ||||
CS POLYBREAK 210 | FTSI | Polymer breaker | Water | 7732-18-5 | 95 | 0.00748 | 0 | |
Sodium Hydroxide | 1310-73-2 | 0 | 0 | 0 | ||||
Sodium chlorite | 7758-19-2 | 5 | 0.00039 | 3796 | ||||
NPD-3000 | FTSI | Flow-back additive | Silicon dioxide | 7631-86-9 | 20 | 0.00014 | 343 | |
1-Dodecane sulfonic acid, hydroxy-, sodium salt | 128824-30-6 | 2 | 0.00001000 | 0 | ||||
Ethylene glycol | 107-21-1 | 10 | 0.00007000 | 0 | ||||
Sodium sulfate | 7757-82-6 | 0.13 | 0 | 0 | ||||
Dodecene-1sulfonic acid, sodium salt | 30965-85-6 | 5 | 0.00004000 | 0 | ||||
Mixture of Surfactants | 3rd Party Proprietar | 1 | 0.00001000 | 0 | ||||
Methyl alcohol | 67-56-1 | 2 | 0.00001000 | 0 | ||||
1-Dodecene | 112-41-4 | 0.25 | 0 | 0 | ||||
Butyl Cellusolve | 111-76-2 | 1 | 0.00001000 | 0 | ||||
Tetrapropylammonium bromide | 1941-30-6 | 10 | 0.00007000 | 0 | ||||
Water | 7732-18-5 | 15 | 0.00011 | 0 | ||||
3rd Party Trade Secret | Undisclosed | 1 | 0.00001000 | 0 | ||||
Water | Operator | Carrier | Water | 7732-18-5 | 100 | 84.365 | 40,670,300.0 | |
CS-750 SI | FTSI | Scale Inhibitor | Glycerin | 56-81-5 | 20 | 0.00433 | 10438 | |
3rd party proprietary | 3rd party proprietar | 25 | 0.00541 | 0 | ||||
Water | 7732-18-5 | 60 | 0.01299 | 0 | ||||
APB-1 | FTSI | Gel breaker | Ammonium Persulfate | 7727-54-0 | 100 | 0.0003 | 146 | |
LEB-300 | FTSI | Breaker | Water | 7732-18-5 | 90 | 0.00014 | 0 | |
Sodium Chloride | 7647-14-5 | 20 | 0.00003000 | 0 | ||||
Enzyme | Proprietary | 1 | 0 | 0 | ||||
No Hazardous Materials | Not available. | 0 | 0 | 74 | ||||
NE-100 | FTSI | Non-emulsifier | Unsulphonated Matter | 3rd Party Proprietar | 0.03 | 0.00002000 | 0 | |
Sulfuric Acid | 7664-93-9 | 0.01 | 0.00001000 | 0 | ||||
2-Butoxyethanol | 111-76-2 | 10 | 0.00779 | 37558 | ||||
Benzene, C10-16 Alkyl Derivatives | 68648-87-3 | 0.04 | 0.00003000 | 0 | ||||
Sulfur Dioxide | 7446-09-5 | 0 | 0 | 0 | ||||
2-Propanol | 67-63-0 | 10 | 0.00779 | 0 | ||||
Water | 7732-18-5 | 90 | 0.07012 | 0 | ||||
Dodecylbenzenesulfonic acid | 27176-87-0 | 5 | 0.0039 | 0 | ||||
LTB-1 | FTSI | Breaker | Cured acrylic resin | Proprietary | 100 | 0.01001 | 0 | |
3rd Party Proprietary | Not available. | 0 | 0 | 0 | ||||
Ammonium Persulfate | 7727-54-0 | 100 | 0.01001 | 4827 | ||||
Silica, Crystalline- Quartz | 14808-60-7 | 10 | 0.001 | 0 | ||||
HVG-1 | FTSI | Water Gelling Agent | Ethylene glycol monobutyl ether | 111-76-2 | 0.25 | 0.0005 | 0 | |
Clay | 14808-60-7 | 2 | 0.004 | 0 | ||||
Petroleum Distillate | 64742-47-8 | 55 | 0.10987 | 0 | ||||
Guar Gum | 9000-30-0 | 50 | 0.09988 | 96300 | ||||
Surfactant | 68439-51-0 | 2 | 0.004 | 0 | ||||
BIO-3240 | FTSI | Biocide | Sodium Hydroxide | 1310-73-2 | 23 | 0.00862 | 0 | |
Dazomet (Tetrahydro-3, 5-dimethyl-2H-1,
3, 5-thiadiazine-2-thione. |
533-74-4 | 24 | 0.009 | 18074 | ||||
Water | 7732-18-5 | 55 | 0.02062 | 0 | ||||
100 Mesh Sand | FTSI | Proppant | 100 Mesh Sand | 14808-60-7 | 100 | 0.11616 | 56000 | |
30/50 White | FTSI | Proppant | 30/50 White | 14808-60-7 | 100 | 10.8069 | 5,209,750.0 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-06-19 | H2O | 8 | 5843 Bbl | 390860 | Frac Tech Services | STAGE 10 |
2013-06-16 | H2O | 8 | 11224 Bbl | 380220 | Frac Tech Services | STAGE 1
30 SHOTS |
2013-06-18 | H2O | 8 | 4401 Bbl | 381335 | Frac Tech Services | STAGE 7 |
2013-06-17 | H2O | 8 | 5752 Bbl | 377024 | Frac Tech Services | STAGE 6 |
2013-06-18 | H2O | 8 | 5443 Bbl | 382300 | Frac Tech Services | STAGE 9 |
2013-06-17 | H2O | 8 | 6415 Bbl | 380380 | Frac Tech Services | STAGE 5 |
2013-06-21 | H2O | 8 | 3333 Bbl | 390801 | Frac Tech Services | STAGE 18 |
2013-06-09 | H2O | 8 | 1551 Bbl | 6300 | Frac Tech Services | STAGE 11 |
2013-06-17 | H2O | 8 | 8391 Bbl | 401127 | Frac Tech Services | STAGE 4 |
2013-06-20 | H2O | 8 | 5153 Bbl | 367400 | Frac Tech Services | STAGE 14 |
2013-06-21 | H2O | 8 | 5935 Bbl | 382300 | Frac Tech Services | STAGE 16 |
2013-06-20 | H2O | 8 | 5092 Bbl | 383820 | Frac Tech Services | STAGE 13 |
2013-06-20 | H2O | 8 | 5800 Bbl | 383380 | Frac Tech Services | STAGE 15 |
2013-06-20 | H2O | 8 | 6901 Bbl | 381780 | Frac Tech Services | STAGE 12 |
2013-06-21 | H2O | 8 | 7425 Bbl | 369260 | Frac Tech Services | STAGE 17 |
2013-06-18 | H2O | 8 | 5485 Bbl | 380980 | Frac Tech Services | STAGE 8 |
2013-06-16 | H2O | 8 | 6582 Bbl | 398666 | Frac Tech Services | STAGE 2 |
2013-06-16 | H2O | 8 | 6120 Bbl | 375600 | Frac Tech Services | STAGE 3 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | HALCON OPERATING COMPANY INC | 6339 | 843 | 45 |
2014 | HALCON OPERATING COMPANY INC | 88250 | 2436 | 317 |
2015 | HALCON OPERATING COMPANY INC | 61040 | 555 | 332 |
2016 | HALCON OPERATING COMPANY INC | 49678 | 437 | 365 |
2017 | PIN OAK ENERGY PARTNERS LLC | 33345 | 178 | 271 |
2018 | PIN OAK ENERGY PARTNERS LLC | 46306 | 330 | 360 |
2019 | PIN OAK ENERGY PARTNERS LLC | 6323 | 127 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | HALCON OPERATING COMPANY INC | Brine | 9608 | 45 |
2014 | HALCON OPERATING COMPANY INC | Brine | 2342 | 317 |
2015 | HALCON OPERATING COMPANY INC | Brine | 690 | 332 |
2016 | HALCON OPERATING COMPANY INC | Brine | 393 | 365 |
2017 | PIN OAK ENERGY PARTNERS LLC | Brine | 165 | 271 |
2018 | PIN OAK ENERGY PARTNERS LLC | Brine | 143 | 360 |
2019 | PIN OAK ENERGY PARTNERS LLC | Brine | 98 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-104456444 | 2018-11-6 0:00: | PW | No Violations | 1.00 |
-1144639876 | 2013-6-6 0:00:0 | CT | No Violations | 7.00 |
-1293446105 | 2013-10-15 0:00 | CT | No Violations | 2.00 |
-1338135424 | 2013-10-22 0:00 | CT | No Violations | 1.00 |
-1838277122 | 2014-1-22 0:00: | SC | No Violations | 2.00 |
-1852427356 | 2014-1-31 0:00: | PW | No Violations | 1.00 |
-398815099 | 2015-12-9 0:00: | PW | No Violations | |
-469522584 | 2013-5-21 0:00: | DD | No Violations | 2.00 |
-649515369 | 2013-10-8 0:00: | PW | No Violations | 2.00 |
-781655414 | 2013-4-30 0:00: | DD | No Violations | 2.00 |
0104456444 | 2018-11-06 | Production Wells | No Violations | I performed an inspection on the above location. The well is equipped with 2-7/8 tubing. The tank battery has one 240 barrel tank and one 200 barrel tank and one vertical separator and one flair stack. ID signs are posted. No noted violations at this time. |
0398815099 | 2015-12-09 | Production Wells | No Violations | Water impoundment area has been reclaimed. The well is in production. ID signs are posted. No noted violations at this time. |
0469522584 | 2013-05-21 | Drill / Deepen / Reopen | No Violations | I was on location to perform a status check. Drilling location is free of debris and fire extinguishers were in place. All safety lanes were marked. Permit posted in the company shack. No violations at this time. At this time they are at a depth of 7424. |
0649515369 | 2013-10-08 | Production Wells | No Violations | I met with Halcons personal on location. They instructed me that they would be moving a workover rig on location to pull tubing and spot some acid and Universal Well Service would due a mini nitrogin frac on the above location. |
0650726189 | 2013-08-14 | Completion Testing | No Violations | I performed a follow up inspection on the above location. The clean up is still in progress. Excavators are removing the contaminated soil and loading it into roll of containers to be disposed of. Doug Oaks Halcons representative was on location. |
0781655414 | 2013-04-30 | Drill / Deepen / Reopen | No Violations | I performed a status check on the above location, Patterson Rig 256 was at 4560 As I walked the location all safety signs and notices were posted, location is clean of contamination . No noted violations were noted at this time. |
0796225578 | 2013-08-12 | Completion Testing | No Violations | I received a phone call from Doug Oaks that FESCO the company flow testing the above well ran a 500 barrel frac tank over and about 8-10 barrels of flow back / condensate got out of the contaminate and onto the ground. A water truck was on location and vacuumed up all fluids on the ground. A contractor is on location with a back hoe and rollbacks are in place to remove contaminated soil and properly dispose of. The area effected was 6 wide by 80 long. They will be testing the depth of the soil also and removing if needed. |
0854813172 | 2013-10-11 | Completion Testing | No Violations | I performed a status check on the above location. The work over rig is still on location. All safety lanes are marked, fire extinguishers are in place, containment is down all frac tanks are in containment. |
0936340554 | 2013-09-03 | Completion Testing | No Violations | I performed a status check on the above location. At present there is no active this on this location. There is ( 4 ) - 500 barrel frac tanks on location at this time they are hauling all fluids to disposal wells. |
1083905499 | 2013-04-25 | Drill / Deepen / Reopen | No Violations | I was on location for the cementing of the 13 3/8 casing. The drill depth was 1046 ft, with a 17.5 inch hole and 13 3/8 inch conductor casing placed at a depth of 1036.22 ft. The proper circulation was established and cementing was started by Halliburton using Class A cement with 50 % excess brought for the job. The beginning mudscale of cement was a density of 15.6 pounds per gallon (ppg). The amount of returns were determined to be 10 BBLs. The well site was in good repair with the proper containment in place. The lease road and well pad were in stable condition. The permit was in the company mans trailer. Fire extinguishers were readily available during the job. |
1144639876 | 2013-06-06 | Completion Testing | No Violations | I was on location to observe the construction of the frac head and values and pressures testing on the above location. This is a pretest before fracing. The 13 3/8 surface and 9 5/8 intermediate were installed with pressure gages to monitor the pressures. The 5.5 production casing was loaded with fresh water and a pump was installed to perform the hydro test. The 11634 of P-10 5.5 casing was tested @ 12500 psi for 30 minutes test passed there was no psi on the 13 3/8 or 9 5/8. The three values on the frac head were tested to 15000 psi. and passed the test. |
1210432494 | 2013-08-15 | Completion Testing | No Violations | I performed a status check on the above location. Simak Excavating is on location spreading top soil and seeding. Clean up is complete. No violations at this time. |
1293446105 | 2013-10-15 | Completion Testing | No Violations | I performed a status check on the above location. The work over rig is still on location. All safety lanes are marked, fire extinguishers are in place, containment is down all frac tanks are in containment. |
1338135424 | 2013-10-22 | Completion Testing | No Violations | I performed a status check on the above location. At present they are preparing the well for flow back and clean up operation. They will call me when they start flaring gas. Location is clean. All safety signs are posted. |
1365691114 | 2013-03-13 | Drill / Deepen / Reopen | No Violations | North East Region Supervisor Tom Hill and myself performed a pre-site application permit inspection with Halcons personal, Mike McCadle Construction Supervisor and Gregg Stewart Regulatory Specialist. I GPS the well stake ( 40.112150 -80.897060 ) All wet land were identified and marked. All ID signs to be posted at the Bailey Court West entrance. I will be notified before site construction begins. |
1368556997 | 2013-04-22 | Drill / Deepen / Reopen | No Violations | Patterson Rig 256 drilled a 26 open hole to a total depth of 630 and ran 616 of 18.625 J-55 BTC 87.5# casing pipe with 4 centralizes. Pattersons Rig 256 ran back in the 18.625 casing with a string of 5 drill pipe and 3 joints of 2.875 tubing and latched onto a cement stinger in the bottom of the cement shoe. Halliburton pumped 1196 sacks of standard blend 15.6 cement / 1.22 yield cement and displaced with 5.5 barrels to clear drill pipe and 2.875 tubing of cement. Good circulation and 12 barrels of cement returns to surface. |
1369831474 | 2013-04-22 | Drill / Deepen / Reopen | No Violations | I was on location to cement 615 of 18.625 conductor casing. Good circulation. We had 12 barrels returned to surface. |
1372094643 | 2013-05-28 | Drill / Deepen / Reopen | No Violations | Patterson Rig 256 drilled to a total depth of 10792. They are preparing to power wash the rig before they move, there is vacuum trucks on location to vacuum the residual from the containment pad as they clean the drilling rig. |
1375281629 | 2013-06-19 | Drill / Deepen / Reopen | No Violations | I performed a status check on the above location. FracTec is on location fracing Davidson 1-H well. All danger areas are marked with yellow caution tape, fire extinguishers are placed at various locations on the drill pad. No violations were noted at this time. |
1378315345 | 2013-08-07 | Completion Testing | No Violations | I performed a status check on the above location. FESCO is on site performing a flow test. There is a flare. North Jackson Police and Fire Personal have been notified. All equipment is on containment, safety lanes are marked and fire extinguishers are in place. No violations at this time |
1383573462 | 2013-10-10 | Completion Testing | No Violations | I performed a status check on the above location. The work over rig is still on location they are changing the wellhead out so they can pull tubing. |
1384268316 | 2013-10-28 | Completion Testing | No Violations | I performed a status check on the above location. At present they are preparing the well for flow back and clean up operation. FASCO is a testing company that is on location to start testing the above well. The flair line is laid all safety equipment is in place and all safety procedures will be followed during the testing of the well. |
1399905836 | 2014-05-06 | Production Wells | No Violations | I performed a status check on the above location. The tank battery is equipped with one 400 barrel tanks and one 200 barrel water tank and one GPU production unit. The location is also equipped with a flair to burn off tank vapors. The well is equipped with 2 7/8 tubing. ID signs are posted. No noted violations were noted at this time. Preliminary Restoration can not be passed at this time. |
1434379478 | 2015-04-27 | Production Wells | No Violations | I meet with the Federal EPA at this location. They performed an Air Quality Inspection of the well and tank battery. I performed a status check of the tank battery and well head. ID signs are posted. No violations were noted at this time. |
1454338672 | 2016-01-26 | Production Wells | No Violations | DOGRM Staff Fred Romeo performed a status check on the above location. The tank battery is equipped with one 400 barrel tanks and one 200 barrel water tank and one GPU production unit. The location is also equipped with a flair to burn off tank vapors. The well is equipped with 2 7/8 tubing. ID signs are posted. No noted violations were noted at this time. |
1471367342 | 2016-08-15 | Production Wells | No Violations | I performed a status check on the above location. The well is equipped with a 2 plunger. The tank battery has one 140 barrel tank and one 200 barrel tank and one vertical separator. The tank battery has a metal constructed containment. The water impoundment had been removed and the area has established vegetation. ID signs are in place. The area is not fenced but the entrance gate is locked. No noted violations at this time. |
1563797146 | 2019-7-12 0:00: | PW | No Violations | 1.00 |
1592385236 | 2017-08-11 | Production Wells | No Violations | I performed an inspection on the above location. The well equipped with 27/8 tubing. The tank battery has one 240 barrel tank and one 200 barrel tan and one vertical separator. ID signs are posted. No noted violations at this time. |
1644767498 | 2013-06-11 | Drill / Deepen / Reopen | No Violations | They are preparing the location with contaminate before the frac team moves on location. |
1681167087 | 2015-01-22 | Production Wells | No Violations | I performed a status check on the above location. At present this well is in production. A sales line is connected to NCL pipeline.. This well is equipped with one verticial seperator and one 300 barrel tank and one 150 barrel water tank . This site is also equipped with a flare stack. There is a safety shut off located at the entrance of the well pad. ID signs are posted. No noted violations at this time. |
1838277122 | 2014-01-22 | Surface Facility Construction | No Violations | I performed a status check on the above location. Piper liners are installing the flow line and the sales line to the metering station. This well is selling into NCL pipeline. The tank battery containment is also under construction. There will be One 400 barrel production tank and one 140 barrel brine tank. |
1852427356 | 2014-01-31 | Production Wells | No Violations | North Region Supervisior Tom Hill and myself performed a status check on the above location. We talked to a Halcon Company man and he instructed us that they were preparing the well to go into production. No noted violations were noted at this time. |
1869963852 | 2013-07-15 | Drill / Deepen / Reopen | No Violations | I performed a status check on the above location. At this time there is no active the location it is secured with a metal gate and locked. |
1874221489 | 2017-01-13 | Production Wells | No Violations | I performed a status check on the above location. The well is in production and is equipped with 2-7/8 tubing. There is one 300 barrel tanks that are in contaminate and one GPU on location and one 150 barrel tank. ID signs are posted. No noted violations at this time. |
650726189 | 2013-8-14 0:00: | CT | No Violations | 3.00 |
796225578 | 2013-8-12 0:00: | CT | No Violations | 4.00 |
854813172 | 2013-10-11 0:00 | CT | No Violations | 3.00 |
936340554 | 2013-9-3 0:00:0 | CT | No Violations | 1.00 |
For data sources see[10]