If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-099-23201 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.09,"lon":-80.83,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Jackson Township | |
Operator Name: HALCON OPERATING COMPANY INC | |
Well Pad ID: US-OH-000809 | |
Farm/Lease Name: GRENAMYER | |
License Status: Plugged Back | |
License Date: 2013-11-06 | |
Spud Date: 2013-10-17 | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: 14590.00 ft | |
Configuration: Vertical | |
Latitude: 41.090000 | |
Longitude: -80.830000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2013-10-04 | Proposed Formations:POINT PLEASANT, Issued Date:10/4/2013, Expired Date:10/4/2015 12:00:00 PM, Drilling unit acres:359.07, Proposed Well Type:OG, Proposed Well Class:EDPW |
Correction to Well | 2013-10-11 | CORRECTION TO TARGET & TAKE-POINT X,Y COORDINATES. |
Correction to Well | 2013-10-25 | CORRECTION TO SURFACE FOOTAGE AND CASING PROGRAM |
APP | 2013-11-06 | Proposed Formations:UTICA-POINT PLEASANT-TRENTON, Issued Date:11/6/2013, Expired Date:11/6/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
Plugged Back | 2013-12-30 | Borehole data recv'd |
Construction Permit Expires | 2015-11-06 | Borehole data recv'd |
Record Last Modified | 2017-10-23 | Borehole data recv'd |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2014-04-11 | 6718 | 888 | |
6718 | 888 | ||
6718 | 888 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 01/19/2014 | 01/23/2014 | 6794 | 9,156,630.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FE-100L | FTSI | Iron control | Citric acid | 77-92-9 | 55 | 0.00001457 | 2357 |
Water | 7732-18-5 | 60 | 0.00001590 | 0 | ||||
SHALE SURF 1000 | FTSI | Surfactant | Ethoxylated alcohol | Proprietary | 20 | 0.000158382 | 70433 | |
2-Propanol | 67-63-0 | 10 | 0.00007919 | 0 | ||||
Cyclohexene | 5989-27-5 | 10 | 0.00007919 | 0 | ||||
2-Butoxyethanol | 111-76-2 | 10 | 0.00007919 | 0 | ||||
Water | 7732-18-5 | 85 | 0.000673122 | 0 | ||||
Poly-(oxy-1,2-ethanediyl)-alpha-undecyl-omega | 34398-01-1 | 11 | 0.00008711 | 0 | ||||
Methanol | 67-56-1 | 10 | 0.00007919 | 0 | ||||
NE-450W | FTSI | Non-emulsifier | Proprietary | Proprietary | 0 | 0 | 0 | |
Oxyalkylated alcohol | Proprietary | 5 | 0.00003089 | 54942 | ||||
Methanol | 67-56-1 | 25 | 0.000154435 | 0 | ||||
CS-750 SI | FTSI | Scale Inhibitor | Glycerin | 56-81-5 | 20 | 0.00005393 | 23981 | |
Water | 7732-18-5 | 60 | 0.00016178 | 0 | ||||
Proprietary | Proprietary | 25 | 0.00006741 | 0 | ||||
30/50 White | FTSI | proppant | Silica, Quartz | 14808-60-7 | 100 | 0.124141 | 11,041,200.0 | |
FRW-200 | FTSI | Friction reducer | Alcohols (C10-C16), ethoxylated | 68002-97-1 | 4 | 0.00001123 | 0 | |
Alkyloxypolyethyleneoxyethanol | 84133-50-6 | 1 | 0.00000281 | 0 | ||||
Copolymer of acrylamide and sodium acrylate | 25987-30-8 | 33 | 0.00009267 | 0 | ||||
Ammonium Acrylate | 10604-69-0 | 0.5 | 0.00000140 | 0 | ||||
Isopropanol | 67-63-0 | 0.3 | 0.00000084 | 0 | ||||
Ammonium Chloride | 12125-02-9 | 12 | 0.00003370 | 0 | ||||
Sorbitol Tetraoleate | 61723-83-9 | 2 | 0.00000562 | 0 | ||||
Hydrotreated heavy paraffinic | 64742-54-7 | 5 | 0.00001404 | 0 | ||||
Dewaxed heavy paraffinic | 64742-65-0 | 1.5 | 0.00000421 | 0 | ||||
Acrylamide P/W acrylic acid, ammonium salt | 26100-47-0 | 25 | 0.00007020 | 0 | ||||
Alcohols (C12-C16), ethoxylated | 68551-12-2 | 4 | 0.00001123 | 0 | ||||
Water | 7732-18-5 | 48 | 0.000134792 | 0 | ||||
Petroleum distillate hydrotreated light | 64742-47-8 | 26 | 0.00007301 | 24976 | ||||
Surfactant | Proprietary | 7 | 0.00001966 | 0 | ||||
Polyethylene glycol monooleate | 9004-96-0 | 3 | 0.00000842 | 0 | ||||
Alcohols (C12-C14), ethoxylated | 68439-50-9 | 4 | 0.00001123 | 0 | ||||
Sorbitan Monooleate | 1338-43-8 | 3 | 0.00000842 | 0 | ||||
Acrylamide | 79-06-1 | 0.1 | 0.00000028 | 0 | ||||
CI-150 | FTSI | Acid Corrosion Inhibitor | Fatty Acid Salt | Proprietary | 0.1 | 0.00000003 | 0 | |
Isopropanol | 67-63-0 | 30 | 0.00000996 | 2952 | ||||
Ethylene Glycol | 107-21-1 | 30 | 0.00000996 | 0 | ||||
Aromatic aldehyde | Proprietary | 10 | 0.00000332 | 0 | ||||
Alkylene Oxide Block Polymer | Proprietary | 10 | 0.00000332 | 0 | ||||
Aliphatic alcohol | Proprietary | 0.1 | 0.00000003 | 0 | ||||
Dimethylformamide | 68-12-2 | 10 | 0.00000332 | 0 | ||||
Organic amine resin salt | Proprietary | 30 | 0.00000996 | 0 | ||||
Fatty Acid | Proprietary | 0.1 | 0.00000003 | 0 | ||||
Water | 7732-18-5 | 5 | 0.00000166 | 0 | ||||
Quaternary ammonium compound | Proprietary | 10 | 0.00000332 | 0 | ||||
Diethylene glycol | 111-46-6 | 1 | 0.00000033 | 0 | ||||
KCLS-2 | FTSI | KCl Substitute | Water | 7732-18-5 | 60 | 0.00026429 | 0 | |
Methanol | 67-56-1 | 2 | 0.00000881 | 0 | ||||
Quaternary Ammonium Chloride | 70750-07-1 | 60 | 0.00026429 | 39177 | ||||
100 Mesh Sand | FTSI | proppant | Silica, Quartz | 14808-60-7 | 100 | 0.00177201 | 157604 | |
Hydrochloric Acid (HCl) | FTSI | Acid | Hydrogen Chloride | 7647-01-0 | 37 | 0.00463764 | 1,114,800.0 | |
Water | 7732-18-5 | 63 | 0.00789652 | 0 | ||||
Water | Operator | Carrier | Water | 7732-18-5 | 100 | 0.858618 | 76,366,300.0 | |
ICI-3240 | FTSI | Biocide | Water | 7732-18-5 | 55 | 0.000260629 | 0 | |
Sodium Hydroxide | 1310-73-2 | 23 | 0.000108991 | 0 | ||||
Dazomet (Tetrahydro-3, 5-dimethyl-2H-1,
3, 5-thiadiazine-2-thione. |
533-74-4 | 24 | 0.000113729 | 42147 |
For data sources see[4]
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | HALCON OPERATING COMPANY INC | Brine | 23977 | 277 |
2015 | HALCON OPERATING COMPANY INC | Brine | 3200 | 359 |
2016 | HALCON OPERATING COMPANY INC | Brine | 1786 | 365 |
2017 | PIN OAK ENERGY PARTNERS LLC | Brine | 1006 | 331 |
2018 | PIN OAK ENERGY PARTNERS LLC | Brine | 795 | 343 |
2019 | PIN OAK ENERGY PARTNERS LLC | Brine | 322 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1262630605 | 2014-4-21 0:00: | PW | No Violations | 2.00 |
-1469492983 | 2014-2-7 0:00:0 | DD | No Violations | 2.00 |
-1730805377 | 2013-10-17 0:00 | DD | No Violations | 1.00 |
-1753281485 | 2013-12-16 0:00 | DD | No Violations | 9.50 |
0080566648 | 2014-06-13 | Production Wells | No Violations | I performed a follow-up inspection on the above location. They are preparing the location to rework the well. At this time they are laying containment around the area that the equipment will be on. No noted violations at this time. |
0161513566 | 2014-05-21 | Production Wells | No Violations | On 5/21/2014, I was in the Uniontown Office when I received a call from Mike McCardel from Halcon telling me that the bottom of the motor valve on the wellhead had been sand cut and caused a release of some fluids (oil-brine-condensate) in the cellar and an area 20 by 30 around the wellhead. He explained to me that they had roll-offs and super-vacs and sealed tanks and equipment on location removing the contaminated stone. I told him that I would be there with in one hour. When I arrived on location the stone around the well head had been loaded into roll-off boxes and all the stone and fluids in the cellar had been vaccmed into vac boxes. The area is clear of all contaminated stone. I told them that I would re-inspect tommorow ( 5/22/2014) before putting new stone on location. |
0488498602 | 2013-10-28 | Drill / Deepen / Reopen | No Violations | I performed a status check on the above location. Lighting Energy is cutting the 30 conductor off at the top of the cellar and installing a safety fence around the well location. The cement stayed at the cellar floor. |
0499807549 | 2015-09-29 | Production Wells | No Violations | I performed a status check on the above location. There is six 400 barrels tanks and various types of separators and GPU on location. There is also a compressor. ID signs are posted. No noted violations at this time. |
0786614814 | 2017-01-13 | Preliminary Restoration | No Violations | I performed a status check on the above location. The well is in production and is equipped with 2-7/8 tubing. There is six 300 barrel tanks that are in contaminate and one GPU and various fluid knock out systems and one compressor on the location. ID signs are posted. No noted violations at this time. |
0865183568 | 2014-01-22 | Drill / Deepen / Reopen | No Violations | FTS is starting to frac the first stage of the well. Annular pressure will be monitored during the complete job. All safety equipment is in place safe zones are marked. No noted violations at this time. |
0980394408 | 2013-12-18 | Drill / Deepen / Reopen | No Violations | On location to witness part of the BOP and casing test. Green Energy is performing the test. |
1196606623 | 2013-10-11 | Drill / Deepen / Reopen | No Violations | Lighting Energy is moving on location to drill the 36hole for the 30 conductor casing. I met with Pete, a Drilling Forman for Halcon Energy. He stated that they did not know when they would start drilling. There is a drilling permit on location. The site is still under construction. |
1262630605 | 2014-04-21 | Production Wells | No Violations | I performed a status check on the above location. The well is in production. Personal are in the process of removing nonessential equipment from the location. No noted violations were noted at this time. |
1320193717 | 2015-01-22 | Production Wells | No Violations | I performed a status check on the above location. At present this well is in production. This well is equipped with various separator before gone into a compressor. There is six 400 barrel tanks. This site is equipped with a flare stack . There is a safety shut off located at the entrance of the well pad. ID signs are posted. No noted violations at this time. At the entrance to the location there is a fenced in area with one 200 barrel condensate tank before the gas enters into the sales line. |
1381933959 | 2013-09-03 | Drill / Deepen / Reopen | No Violations | I meet with Mike McCardle Construction Forman for Halcon Operating Company and the Construction Forman for J S Paris the contractor performing the sit construction. We walked the location all LODs have been marked all wet lands have been identified. There is two DEOG pipelines that has to be crossed they will install a 12 concrete pad over the lines and then stone. This procedure was recommended by DEOG personal. Then they will start building the entrance and road. |
1383576190 | 2013-10-15 | Drill / Deepen / Reopen | No Violations | Lighting Energy is on location to drill the 36hole for the 30 conductor casing. I met with Pete, a Drilling Forman for Halcon Energy. The cellar has been set. They are drilling the 36 hole. There is a drilling permit on location. The site is still under construction. |
1383580726 | 2013-10-16 | Drill / Deepen / Reopen | No Violations | Lighting Energy is on location to drill the 36hole for the 30 conductor casing. I met with Pete, a Drilling Forman for Halcon Energy. The cellar has been set. They are drilling the 36 hole. At present they are at a depth of 21 . There is a drilling permit on location. The site is still under construction. |
1383585531 | 2013-10-19 | Drill / Deepen / Reopen | No Violations | Lighting Drilling drilled a 36 well bore to a depth 43 by their depth gage. As they ran and welded the 30 casing together and lowered it into the well bore they discovered that the gage was incorrect. They were 10 short of 30 casing. They welded 10 more casing a depth of 53 and cemented it to surface. Universal Well Service pumped 55 barrels of fresh water and ran 15 barrels of gel and flake and pumped 250 sacks of Type 1 3% cacl2 1/4unicele and displaced with 27 barrels of fresh water and lifted 30 of cement in casing. There was 27 barrels of cement returned to surface. |
1384527453 | 2013-11-08 | Drill / Deepen / Reopen | No Violations | I performed a status check on the above location. ID signs are posted at the entrance for the location off of New Road. The entire perimeter of the location has been fenced, 4 man gates were installed at various locations. The main entrance gates are locked. No active at this time. |
1388677110 | 2013-12-20 | Drill / Deepen / Reopen | No Violations | I performed a status check on the above location. At this time Patterson Rig 256 is drilling the 8.575 pilot hole at present they are at 3850. They are also starting to assemble there above ground water impoundment. |
1389370090 | 2013-12-23 | Drill / Deepen / Reopen | No Violations | I performed a status check on the above location. Patterson Rig 256 had drilled an 8.750 hole to a depth of 7000. Schlumberger was on location performing an open hole log. When completed they will spot a cement plug through drill pipe to there kick off point. No violations noted at this time. |
1390494560 | 2014-01-21 | Drill / Deepen / Reopen | No Violations | FTS is moving on location setting up getting ready to start fracing on 1/23/2014. At present they are cleaning the location of debris after the rig move. No noted violations at this time. |
1392312872 | 2014-02-04 | Drill / Deepen / Reopen | No Violations | I performed a status check on the above location. The above ground fresh water impoundment used for fracing has been removed. At present they are preparing to drill out there plugs and run 6400 of 2.875 tubing. |
1395322049 | 2014-02-12 | Production Wells | No Violations | I was on location and observed some of the installing of the 2.875 tubing ( production string ). There was a work over rig and a snubbing unit performing the operation. There was fire extinguishers on location. All safety lanes were marked. No noted violations at this time. |
1406743579 | 2014-05-22 | Production Wells | No Violations | This is a fellow-up from yesterdays 5/21/2014 incident.The location is clear of contaminated materials. At this time there are putting new stone on location. There is no noted violations at this time. |
1409658334 | 2014-05-23 | Production Wells | No Violations | I performed a follow-up inspection on the above location. I walked the around the effected area and found it to be clear of all contaminated stone. They are in the process of putting new stone around the area. ID signs are posted no noted violations at this time. |
1412484562 | 2017-06-08 | Production Wells | No Violations | I performed a status check on the above location. The well is in production and is equipped with 2-7/8 tubing. There is six 300 barrel tanks that are in contaminate and one GPU and various fluid knock out systems and one compressor on the location. ID signs are posted. No noted violations at this time. |
1437954407 | 2019-10-28 0:00 | PW | No Violations | 1.00 |
1454337897 | 2016-01-26 | Production Wells | No Violations | DOGRM Staff Fred Romeo and myself performed a status check on the above location. There is six 400 barrels tanks and various types of separators and GPU on location. There is also a compressor. ID signs are posted. No noted violations at this time. |
1469492983 | 2014-02-07 | Drill / Deepen / Reopen | No Violations | I performed a status check on the above location. They are building the tank battery, there will be three 400 barrel tanks for oil/condensate and three 400 barrel water tanks. They are also building a pad for a 85 horsepower compressor. The work over rig is in the process of drilling out the plugs. No violations were noted at this time. |
1471373080 | 2016-08-15 | Production Wells | No Violations | I performed a status check on the above location. There is six 400 barrels tanks and various types of separators and GPU on location. There is also a compressor. There is also a Mid- Stream area at this location all are gated fenced and locked. ID signs are posted. No noted violations at this time. |
1542720417 | 2018-11-06 | Production Wells | No Violations | I performed a status check on the above location. The well is in production and is equipped with 2-7/8 tubing. There is six 300 barrel tanks that are in contaminate and one GPU and various fluid knock out systems and one compressor on the location. ID signs are posted. No noted violations at this time. |
1563798346 | 2019-7-12 0:00: | PW | No Violations | 1.00 |
161513566 | 2014-5-21 0:00: | PW | No Violations | 4.00 |
1626081182 | 2014-03-05 | Drill / Deepen / Reopen | No Violations | Blue Racer Midstream and Halcon Operating are in the process of laying pipelines and installing metering stations and tanks on the above location. No noted violations were noted at this time. |
1721273485 | 2014-01-13 | Drill / Deepen / Reopen | No Violations | Patterson Rig 256 Drilled to a depth of 14590. They are running the 5.5 production casing. They will call when ready for cementing of the 5.5 casing. The rig is in the process of moving. |
1730805377 | 2013-10-17 | Drill / Deepen / Reopen | No Violations | Lighting Energy is on location to drill the 36hole for the 30 conductor casing. I met with Pete, a Drilling Forman for Halcon Energy. The cellar has been set. They are drilling the 36 hole. At present they are at a depth of 33 . The 36 well bore is full of water they are waiting on water truck. There is a drilling permit on location. The site is still under construction. |
1753281485 | 2013-12-16 | Drill / Deepen / Reopen | No Violations | Patterson Rig 256 drilled a 17.5 hole and ran of 3255 of 13.375 casing with 24 centralizes. Universal Well Service was on location and pumped 10 barrels of water ahead followed by 25 barrels of Gel and pumped 1594 sacks of Gas Block-2%Cacl2,15%CR-3,1/4# Unicele. Followed by 348 sacks of Gas Block-2%Cacl2,15%CR-3,1/4 Unicele. Displaced with 480 barrels of water. Plug down at 7:09 am. 84 barrels of cement returned to surface. This job went into 12/17/2013 a total of 10 hours due to not having enough high pressure pipe on their trucks. Had to wait for more pipe from Wooster Shop. Bad road conditions also. |
1754839277 | 2014-01-18 | Drill / Deepen / Reopen | No Violations | I was on location to witness the cementing of the mouse hole and the rat hole. City Concrete used 4 yards of ready mix to cement the mouse and rat hole to surface. After 1 hour the cement was at the top of the surface. |
2064470946 | 2013-10-18 | Drill / Deepen / Reopen | No Violations | Lighting Energy is on location to drill the 36hole for the 30 conductor casing. I met with Pete, a Drilling Forman for Halcon Energy. The cellar has been set. They are drilling the 36 hole. At present they are at a depth of 40. There is a drilling permit on location. The drilling site is still under construction. |
488498602 | 2013-10-28 0:00 | DD | No Violations | 2.00 |
499807549 | 2015-9-29 0:00: | PW | No Violations | 1.00 |
786614814 | 2017-1-13 0:00: | PL | No Violations | 1.00 |
80566648 | 2014-6-13 0:00: | PW | No Violations | 1.00 |
865183568 | 2014-1-22 0:00: | DD | No Violations | 2.00 |
980394408 | 2013-12-18 0:00 | DD | No Violations | 2.00 |
For data sources see[7]