X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-103-21328

Well Details

Well ID: 34-103-21328
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: Medina Township
Operator Name: LANDMARK 4 LLC
Well Pad ID:
Farm/Lease Name: FRANK GIRMAN
License Status: Final Restoration
License Date: 2017-09-05
Spud Date: 1961-11-08
Spud Drilling Contractor:
Final Drill Date: 1961-12-20
Well Total Depth: 3358.00 ft
Configuration: Vertical
Latitude: 41.200000
Longitude: -81.790000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1961-11-08 UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.
Completed 1961-12-20 UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.
Reached Total Depth 1961-12-20 UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.
Change of Owner 2005-04-14 Operator changed from 503, WILLIAMS J F OILFIELD SER to 1171, EQUITY OIL & GAS FUNDS IN
Change of Owner 2009-06-17 Operator changed from 1171, EQUITY OIL & GAS FUNDS IN to 7993, LANDMARK 4 LLC
APP 2017-09-05 Proposed Formations:CLINTON, Issued Date:9/5/2017, Expired Date:9/5/2019 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2017-12-13 UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.
Construction Permit Expires 2019-09-05 UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
OIL 0 750 Bbl 27500

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 JOHN F WILLIAMS OIL FIELD SER 1607.00 360.00 0
1985 JOHN F WILLIAMS OIL FIELD SER 1.00 380.00 365
1986 JOHN F WILLIAMS OIL FIELD SER 1291.00 308.00 365
1987 BARCLAY PETROLEUM INC 1138.00 346.00 365
1988 JOHN F WILLIAMS OIL FIELD SER 943.00 224.00 365
1989 JOHN F WILLIAMS OIL FIELD SER 873.00 234.00 365
1990 JOHN F WILLIAMS OIL FIELD SER 1075.00 217.00 365
1991 JOHN F WILLIAMS OIL FIELD SER 11.00 172.00 365
1992 JOHN F WILLIAMS OIL FIELD SER 683.00 169.00 365
1993 JOHN F WILLIAMS OIL FIELD SER 757.00 124.00 365
1994 JOHN F WILLIAMS OIL FIELD SER 815.00 184.00 365
1995 JOHN F WILLIAMS OIL FIELD SER 749.00 140.00 365
1996 JOHN F WILLIAMS OIL FIELD SER 754.00 114.00 365
1997 JOHN F WILLIAMS OIL FIELD SER 764.00 85.00 365
1998 JOHN F WILLIAMS OIL FIELD SER 284.00 188.00 365
1999 JOHN F WILLIAMS OIL FIELD SER 0.00 47.00 365
2000 JOHN F WILLIAMS OIL FIELD SER 0.00 136.00 365
2001 JOHN F WILLIAMS OIL FIELD SER 0.00 149.00 365
2002 JOHN F WILLIAMS OIL FIELD SER 0.00 104.00 365
2003 JOHN F WILLIAMS OIL FIELD SER 0.00 193.00 365
2004 JOHN F WILLIAMS OIL FIELD SER 0.00 160.00 365
2005 EQUITY OIL & GAS FUNDS INC 0.00 0.00 365
2006 EQUITY OIL & GAS FUNDS INC 0.00 72.00 365
2007 EQUITY OIL & GAS FUNDS INC 0.00 0.00 365
2008 EQUITY OIL & GAS FUNDS INC 11.00 0.00 365
2009 LANDMARK 4 LLC 0.00 87.00 0
2010 LANDMARK 4 LLC 0.00 262.00 345
2011 LANDMARK 4 LLC 0.00 352.00 365
2014 LANDMARK 4 LLC 0.00 163.00 365
2015 LANDMARK 4 LLC 0.00 43.00 365
2016 LANDMARK 4 LLC 0.00 110.00 89
2017 LANDMARK 4 LLC 0.00 13.00 30
2018 LANDMARK 4 LLC 0.00 0.00 30

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 JOHN F WILLIAMS OIL FIELD SER Brine 0 0
1985 JOHN F WILLIAMS OIL FIELD SER Brine 10 365
1986 JOHN F WILLIAMS OIL FIELD SER Brine 10 365
1987 BARCLAY PETROLEUM INC Brine 10 365
1988 JOHN F WILLIAMS OIL FIELD SER Brine 10 365
1989 JOHN F WILLIAMS OIL FIELD SER Brine 10 365
1990 JOHN F WILLIAMS OIL FIELD SER Brine 10 365
1991 JOHN F WILLIAMS OIL FIELD SER Brine 5 365
1992 JOHN F WILLIAMS OIL FIELD SER Brine 0 365
1993 JOHN F WILLIAMS OIL FIELD SER Brine 0 365
1994 JOHN F WILLIAMS OIL FIELD SER Brine 0 365
1995 JOHN F WILLIAMS OIL FIELD SER Brine 0 365
1996 JOHN F WILLIAMS OIL FIELD SER Brine 0 365
1997 JOHN F WILLIAMS OIL FIELD SER Brine 0 365
1998 JOHN F WILLIAMS OIL FIELD SER Brine 0 365
1999 JOHN F WILLIAMS OIL FIELD SER Brine 0 365
2000 JOHN F WILLIAMS OIL FIELD SER Brine 0 365
2001 JOHN F WILLIAMS OIL FIELD SER Brine 0 365
2002 JOHN F WILLIAMS OIL FIELD SER Brine 0 365
2003 JOHN F WILLIAMS OIL FIELD SER Brine 0 365
2004 JOHN F WILLIAMS OIL FIELD SER Brine 0 365
2005 JOHN F WILLIAMS OIL FIELD SER Brine 0 365
2006 EQUITY OIL & GAS FUNDS INC Brine 0 365
2007 EQUITY OIL & GAS FUNDS INC Brine 0 365
2008 EQUITY OIL & GAS FUNDS INC Brine 0 365
2009 LANDMARK 4 LLC Brine 0 0
2010 LANDMARK 4 LLC Brine 0 345
2011 LANDMARK 4 LLC Brine 0 365
2014 LANDMARK 4 LLC Brine 0 365
2015 LANDMARK 4 LLC Brine 0 365
2016 LANDMARK 4 LLC Brine 0 89
2017 LANDMARK 4 LLC Brine 0 30
2018 LANDMARK 4 LLC Brine 0 30

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2120394046 2015-7-16 0:00: PW No Violations
-360863147 2019-4-16 0:00: FR No Violations
-780162243 2011-2-12 0:00: UP No Violations 1.00
-940164344 2017-12-6 0:00: PB No Violations
0016879458 2002-07-25 Production Wells No Violations Status check inspection. No violations at this time unless the gas is being vented through the stock tank.
0360863147 2019-04-16 Final Restoration No Violations Performed final restoration inspection on 04/16/2019 with NW Region Supervisor Steve Ochs. No surface expression of the well was noted at the time of the inspection. All production equipment, pipelines, and lease roads known to be associated with the well have been removed. Final restoration passes.
0428749759 2011-07-06 Production Wells No Violations Status check inspection found no violations at this time. The wellhead is identified and the well is in production.
0572643916 2015-03-23 Production Wells No Violations Inspected production well on 03/23/2015 to follow-up on a previously-issued compliance notice. The tank battery consists of 3-100 bbl steel tanks, 1-1,600 gal plastic tank, and 2-vertical separators located within an earthen dike; the diked area is located within a locked metal fence. The tank battery is used by multiple wells (5); well identification is posted for all wells utilizing it, but not all permit numbers are listed. The well is equipped with a pump jack with a hitmiss motor located within a locked metal fence. Well identification is clearly displayed at the wellhead. Received 2014 production data from Landmark (which was turned in to Steve Opritza). Production data shows production for both 2013 (174 bbl oil) and 2014 (163 bbl oil). As production has been filed and the well is currently in production, compliance notices can be closed.
0780162243 2011-02-12 UrbanProduction Wells Violations Noted Well is in production and equipped with pump jack. 2-100 barrel tanks in battery. Fences around well and tank battery needs raised to 8 with 3 strands of barbed wire on top of fence. Well needs to be flared. No sales line available for natural gas. Flare must be a minimum of 100 from well or tank battery. Update production reports by March 2011.
0940164344 2017-12-06 Plug / Plug Back No Violations Arrived on location on 12/06/2017 to witness plugging operations. Waited on rig crew to arrive. Received call relating that plugging operations had been pushed back. As Norburt Lowder was available for later operations, the location was left.
1393213126 2014-05-23 Production Wells Violations Noted Inspected production well on 05/23/2014. The tank battery consists of 3-100 bbl steel tanks, 1-1,500 gal plastic tank, and 2-vertical separators located within an earthen dike; the diked area is located within a locked metal fence. The tank battery is used by multiple wells; identification is posted for all wells utilizing it, but does not lists permit numbers for the wells. The well is equipped with a pump jack with a gas-powered motor located within a locked metal fence. Well identification is posted at the wellhead as required. Research into the production history showed that no production has been filed since 2011, therefore the well must be plugged.
1537799107 2017-11-30 Plug / Plug Back No Violations Conducted compliance inspection this day to witness the plugging operation, Contractor (Moore well Service) was on site rigging up to perform the plugging operation this day they pulled Rods, then pulled tubing but due to the paraffin build -
16879458 2002-7-25 0:00: PW No Violations
1756068483 2017-12-05 Plug / Plug Back No Violations Witnessed plugging operations at the location on 12/05/2017. Moore Well Service tagged cement at 2,883, and ripped 5 1/2 production casing at 2,117. Rigged up Petroset, broke circulation, and pumped the Big Lime/Oriskany plug.
2120394046 2015-07-16 Production Wells No Violations Inspected production well on 07/16/2015. The tank battery consists of 3-100 bbl steel tanks, 1-2,100 gal plastic tank, and 2-vertical separators located within an earthen dike. The diked area is located within a locked metal fence. The tank battery is used by multiple wells (4); well identification is posted for all wells utilizing it. The well is equipped with a pump jack with a hitmiss motor located within a locked metal fence. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
428749759 2011-7-6 0:00:0 PW No Violations
572643916 2015-3-23 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0780162243 US-OH-128847 2011-02-14 FENCING (a-d)
0780162243 US-OH-128848 2011-02-14 Unlawful venting or flaring of gas
0780162243 US-OH-128849 2011-02-14 Statement of annual production not filed
1393213126 US-OH-111610 2014-06-05 Well shall be plugged
1393213126 US-OH-111611 2014-06-05 Statement of annual production not filed

For data sources see[8]

References