X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-103-22785

Well Details

Well ID: 34-103-22785
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: Sharon Township
Operator Name: BRAMLEY MATTHEW W
Well Pad ID:
Farm/Lease Name: BRAMLEY
License Status: Producing
License Date: 1982-01-08
Spud Date: 1982-01-05
Spud Drilling Contractor:
Final Drill Date: 1982-01-12
Well Total Depth: 3850.00 ft
Configuration: Vertical
Latitude: 41.090000
Longitude: -81.700000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1982-01-05
CO 1982-01-08 2348 TRIAD RESOURCES INC GeoDate 1/8/82
Completed 1982-01-12
Reached Total Depth 1982-01-12
CO 1996-04-04 1217 HARRISON ENERGY GeoDate 1/8/82
Change of Owner 2006-02-07 Operator changed from 1217, HARRISON ENERGY to 5899, BRAMLEY MATTHEW M
Change of Owner 2006-02-07 Operator changed from 5899, BRAMLEY MATTHEW M to 3558, BRAMLEY MATTHEW W
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3621 3659 19
3621 3659 19
3621 3659 19

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1986 TRIAD RESOURCES INC 1303.00 364.00 365
1987 TRIAD RESOURCES INC 2440.00 258.00 365
1988 TRIAD RESOURCES INC 1786.00 164.00 365
1989 TRIAD RESOURCES INC 1291.00 97.00 365
1990 GEITGEY DONALD W JR 1053.00 236.00 365
1991 TRIAD RESOURCES INC 1082.00 236.00 365
1992 TRIAD RESOURCES INC 673.00 120.00 365
1993 TRIAD RESOURCES INC 917.00 120.00 365
1994 TRIAD RESOURCES INC 754.00 90.00 365
1995 TRIAD RESOURCES INC 616.00 106.00 365
1996 HARRISON ENERGY 102.00 0.00 30
1997 BRAMLEY MATTHEW M 55.00 0.00 90
2006 BRAMLEY MATTHEW M 0.00 75.00 365
2008 BRAMLEY MATTHEW M 200.00 30.00 300
2009 BRAMLEY MATTHEW W 0.00 30.00 365
2010 BRAMLEY MATTHEW M 0.00 60.00 365
2012 BRAMLEY MATTHEW W 0.00 67.00 366
2013 BRAMLEY MATTHEW W 0.00 39.00 365
2014 BRAMLEY MATTHEW W 0.00 48.00 365
2015 BRAMLEY MATTHEW W 0.00 60.00 365
2016 BRAMLEY MATTHEW W 0.00 68.00 365
2017 BRAMLEY MATTHEW W 50.00 32.00 365
2018 BRAMLEY MATTHEW W 0.00 67.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1986 TRIAD RESOURCES INC Brine 0 365
1987 TRIAD RESOURCES INC Brine 0 365
1988 TRIAD RESOURCES INC Brine 0 365
1989 TRIAD RESOURCES INC Brine 0 365
1990 GEITGEY DONALD W JR Brine 0 365
1991 TRIAD RESOURCES INC Brine 0 365
1992 TRIAD RESOURCES INC Brine 0 365
1993 TRIAD RESOURCES INC Brine 0 365
1994 TRIAD RESOURCES INC Brine 0 365
1995 TRIAD RESOURCES INC Brine 0 365
1996 HARRISON ENERGY Brine 0 30
1997 BRAMLEY MATTHEW M Brine 0 90
2006 BRAMLEY MATTHEW M Brine 1 365
2008 BRAMLEY MATTHEW M Brine 2 300
2009 BRAMLEY MATTHEW W Brine 1 365
2010 BRAMLEY MATTHEW M Brine 1 365
2012 BRAMLEY MATTHEW W Brine 3 366
2013 BRAMLEY MATTHEW W Brine 1 365
2014 BRAMLEY MATTHEW W Brine 10 365
2015 BRAMLEY MATTHEW W Brine 3 365
2016 BRAMLEY MATTHEW W Brine 3 365
2017 BRAMLEY MATTHEW W Brine 7 365
2018 BRAMLEY MATTHEW W Brine 14 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-517363117 2014-6-26 0:00: PW No Violations
000PL12059 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0517363117 2014-06-26 Production Wells No Violations Inspected production well on 06/26/2014. The tank battery consists of 1-100 bbl steel tank and 1-25 bbl steel tank located within an earthen dike. Multiple small leaks were noted at the piping between the tanks, but all are very small, contained within the dike, and should be easily repaired. The tank battery is used by multiple wells (2); identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. A very small leak was noted at the stuffing box. Well identification is posted at the wellhead, but it is too faded to read. An additional 100 bbl steel tank within an earthen dike is located near the wellhead, but no identification is posted on it. Mr. Bramley was notified of these issues and will address them as soon as possible. No other problems were noted at the time of the inspection.
1349801809 2012-09-27 Production Wells No Violations I inspected this well and found one pump jack with electric motor on the wellhead. There was 100 psi on the tubing, but I could not determine the casing pressure as there was no gauge on it. No visible leaks were detected on or near the wellhead. The area around the wellhead was well maintained, but there was no identification sign on the well. The tank battery contained one 100 bbl. steel oil storage tank and one 50 bbl. steel brine tank. The dike was in good shape and the area within and around the tank battery was well maintained. There was no identification sign on either tank. It was determined that this tank battery was being used for this well and the Bramley-Stacy well. I spoke with the well owner, Bill Bramley, and advised him of the need to have the proper identification signage installed on the well and tank battery. He told me that he will have the proper signs made and installed within two weeks. I also advised him that the records for this well show no production reports have been submitted for year 2011 and that he needs to submit them to the ODNR as soon as possible.
PL12059 PL No Violations

For data sources see[9]

References