X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-103-22981

Well Details

Well ID: 34-103-22981
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: Chatham Township
Operator Name: MEDINA PETROLEUM CO
Well Pad ID:
Farm/Lease Name: PHILLIPS LEASE
License Status: Producing
License Date: 1982-02-05
Spud Date: 1982-01-22
Spud Drilling Contractor: LUCKY WELLS DRLG
Final Drill Date: 1982-01-28
Well Total Depth: 625.00 ft
Configuration: Vertical
Latitude: 41.100000
Longitude: -82.000000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1982-01-22
Completed 1982-01-28
Reached Total Depth 1982-01-28
Completion Report Received 1982-02-01
CO 1982-02-05 514 MEDINA PETROLEUM CO GeoDate 2/5/82
Oil and Gas 1982-02-05 Issued Date 2/8/82 Expired Date 8/7/82 Acres 0001000 Tool Type CRA Proposed Formation BEREA Proposed Depth 00625 Proposed Drill Depth 00625
Construction Permit Expires 1982-08-07
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 546 584 1
546 584 1
546 584 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 150 Qts 0 150 QT NITRO

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
000PL11989 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
1537542091 2018-09-19 Production Wells No Violations Conducted compliance inspection to follow-up on H2S readings of 15 PPM that was encountered during a service job. I advised contractor (Dave Bishop) to make the call to Emergency Response to an official report.

This inspection found contractor had installed fans to direct air flow over well casing and windsock direction of wind. Gas meters for each personnel in the operation area and conducted a conducted a safety meeting this morning to establish a safety rallying point if the H2S reappears during the service operation. The tank battery consists of 2-100 bbl. steel tanks and 1-50 bbl. steel tank located within an earthen dike. Well identification is clearly displayed at the tank battery. 1-horizontal separator and a small compressor station are located nearby. The well is equipped with a pump jack with an electric motor. No Compliance issue were found at time of this inspection.

PL11989 PL No Violations

For data sources see[5]